Harman Kardon DVD 37 (serv.man3) EMC - CB Certificate ▷ View online
- Page 3 of 10 -
www.nemko.com
Report No. 69608
Copy of marking plate:
Marking for model, DVD 37/230
- Page 4 of 10 -
www.nemko.com
Report No. 69608
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure.
enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ................................... :
Brand name and model name
marked,
see copy of marking plate.
marked,
see copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol .......................... :
230V and AC-symbol (
~
) used
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ..................... :
13W
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
External supply cord only,
double insulated.
double insulated.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires in external
cords connected with multi-
contact-housing.
cords connected with multi-
contact-housing.
P
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Mains plug is used as
disconnect device
disconnect device
P
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved mains plug provided.
See list of critical components.
See list of critical components.
P
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Standard connectors provided
for S-Video, SCART, Optical,
HDMI (optional) and RCA
terminals.
for S-Video, SCART, Optical,
HDMI (optional) and RCA
terminals.
P
- Page 5 of 10 -
www.nemko.com
Report No. 69608
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
Sheathed PVC cord
complying with IEC 60227
complying with IEC 60227
P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Class II apparatus
N
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
The cord is 0,75mm², within the
current rating
current rating
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
Cord complying with 16.1.
N
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Cords have adequate cross-
sectional areas to avoid
temperature rise under normal
and fault conditions.
sectional areas to avoid
temperature rise under normal
and fault conditions.
P
16.5
Adequate strain relief on external flexible cords
Cord clip wedged in the
enclosure
enclosure
P
Not possible to push cord back into equipment
Checked by inspection
P
Strain relief device unlikely to damage flexible cord
No sharp edges
P
For mains cords of Class I equipment, hazardous
live conductors become taut before earth
conductor
live conductors become taut before earth
conductor
Class II apparatus.
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
No sharp edges
P
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
No such apparatus.
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
No such apparatus.
N
- Page 6 of 10 -
www.nemko.com
Report No. 69608
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Mains plug/cord
(For CENELEC
Countries) *)
(For CENELEC
Countries) *)
Kenic Electric MFG
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
0.75mm
0.75mm
2
x 2
IEC60884-1 VDE
alt.
Kenic Electric MFG
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
0.75mm
0.75mm
2
x 2
IEC60884-1 VDE
alt.
Volex (Asia) Pte.
Ltd.
Ltd.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
0.75mm
0.75mm
2
x 2
IEC60884-1 VDE
Mains plug/cord
(For UK) *)
(For UK) *)
Luen Tai (IPS) Elect.
Kenic Electric MFG
Kenic Electric MFG
BS9518
H03VVH2-F
H03VVH2-F
, or
H05VVH2-F
13A/250V
0.75mm
0.75mm
2
x 2
BS1363
BS6500
BS6500
BSI
Mains plug/cord
(For UK or
Singapore) *)
(For UK or
Singapore) *)
Kenic Electric MFG
KE-108
H03VVH2-F
H03VVH2-F
, or
H05VVH2-F
13A/250V
0.75mm
0.75mm
2
x 2
BS1363
SS145
BS6500
SS145
BS6500
BSI
PSB
PSB
Mains cord set
**)
**)
See summary of testing
Appliance inlet
**)
**)
Rong Feng Industrial RF-180
2,5A/250V~
IEC60320
VDE
Mains fuse
(F901) alt.
alt.
alt.
alt.
alt.
(F901) alt.
alt.
alt.
alt.
alt.
Littelfuse
Bel fuse Ltd.
Orisel
Schurter AG
Sun Electronics
Walter Electronic
Bel fuse Ltd.
Orisel
Schurter AG
Sun Electronics
Walter Electronic
218
5ST
50T
FST
5T
TSD
5ST
50T
FST
5T
TSD
T2A L 250V
IEC 60127
SEMKO
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Transformer
(T901) alt.
Bobbin Mtl.
alt.
alt.
(T901) alt.
Bobbin Mtl.
alt.
alt.
Dong Heung Elect.
Kwang Sung Elect.
Bakelite AG
Sumitomo Bakelite
Chang Chun Plastics
Kwang Sung Elect.
Bakelite AG
Sumitomo Bakelite
Chang Chun Plastics
CLT9Z021ZE
CLT9Z018ZE
PF2736
PM8375
T-355J
CLT9Z018ZE
PF2736
PM8375
T-355J
.
Class A
V-0, 150
V-0, 150
°C
V-0, 150
°C
V-0, 150
°C
IEC60065
clause 14.3
UL94
UL94
UL94
clause 14.3
UL94
UL94
UL94
1.)
UL,
UL,
E61040
UL,
E41429
UL,
E59481
Line filter
(LF91) alt.
Bobbin Mtl.
alt.
alt.
(LF91) alt.
Bobbin Mtl.
alt.
alt.
Dong Heung Elect.
Kwang Sung Elect.
Bakelite AG
Sumitomo Bakelite
Chang Chun Plastics
Kwang Sung Elect.
Bakelite AG
Sumitomo Bakelite
Chang Chun Plastics
CLT9Z060Z
CLZ9Z060Y
PF2736
PM8375
T-355J
CLZ9Z060Y
PF2736
PM8375
T-355J
Class A
V-0, 150
V-0, 150
°C
V-0, 150
°C
V-0, 150
°C
IEC60065
clause 14.3
UL94
UL94
UL94
clause 14.3
UL94
UL94
UL94
1.)
UL,
UL,
E61040
UL,
E41429
UL,
E59481
1
) an asterisk indicates a mark which assures the agreed level of surveillance
*) For models, DVD 27/230 and DVD 37/230
**) For model, DVD 47/230 only
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
Click on the first or last page to see other DVD 37 (serv.man3) service manuals if exist.