DOWNLOAD Harman Kardon DVD 29 (serv.man3) Service Manual ↓ Size: 1.49 MB | Pages: 61 in PDF or view online for FREE

Model
DVD 29 (serv.man3)
Pages
61
Size
1.49 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-29-sm3.pdf
Date

Harman Kardon DVD 29 (serv.man3) EMC - CB Certificate ▷ View online

 
 
- Page 30 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 N/A 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2 
 N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard 
 N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this standard
 N/A 
 
Complies with IEC 62151 clause 6  
 N/A 
 
Complies with IEC 62151 clause 7  
 N/A 
 
Complies with IEC 62151 annex A, B and C 
 N/A 
 
 
- Page 31 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
 
IEC 62151 clause 4.1.1: 
Add after the first paragraph: 
 
NOTE- In Finland, Norway and Sweden, class I 
equipment which is intended for connection to the 
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet. 
 
The marking text in the applicable countries shall be 
as follow: 
 
In Finland,  
"Laite on liitettävä suojamaadoituskoskettimilla va 
rustettuunpistorasiaan” 
 
In Norway, 
"Apparatet må tilkoples jordet stikkontakt" 
 
In Sweden, 
"Apparaten skall anslutas till jordat uttag” 
Class II apparatus 
N/A 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPHIC PURPOSES. 
N/A 
L5.4 
Marking and Instructions 
No electronic flash  
apparatus 
N/A 
L9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE 
 N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in Table  
3 , unless comply with 6.3.2 of IEC 60086-4 
 N/A 
L14.6.6 
Mains switch characteristics   appropriate to its 
function under normal conditions 
 N/A 
 
 
- Page 32 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
No mains switch 
 
 
Position of the functional switch (W) : 
Functional switch “OFF” / 0,9W 
— 
 
Operating conditions 
Functional switch “OFF” mode: at 50Hz
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 
0,019 0,8  — 
220 
0,020 0,8  — 
230 
0,020 0,8  — 
253 
0,020 0,9  — 
Functional switch “OFF” mode:
 at 60Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 
0,019 0,7  — 
220 
0,020 0,8  — 
230 
0,022 0,9  — 
242 
0,022 0,9  — 
253 
0,022 0,9  — 
 
Measured at DVD play mode: at 50Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 0,158 14,2 
 
220 0,147 14,3 
 
230 0,143 14,3 
 
253 0,134 14,4 
 
Measured at DVD play mode: at 60Hz 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 0,149 14,1 
 
220 0,141 14,3 
 
230 0,136 14,3 
 
242 0,131 14,3 
 
253 0,127 14,3 
 
 
 
- Page 33 of 40 - 
 
 
 
 
 Report 
No. 
89538 
 
TRF No:  IEC/EN 60065G 
 
Monitored point: 
Δt measured 
at 198V/50Hz
Δt measured
at 198V/60Hz
Δt measured
at 253V/50Hz
Δt measured 
at 253V/60Hz 
Limit dT (K)  
**) 
DVD Spindle motor case 
9,7 9,6 10,2 
9,8 
D904 body 
17,5 16,9 17,8 17,2 
D920 body 
49,8 49,8 51,4 51,9 
IC49 body 
49,0 49,1 49,8 49,7 
IC24 body 
49,3 49,4 49,7 50,8 
IC19 body 
43,0 43,5 43,7 43,0 
E. Capacitor, C903 body 
19,6 19,2 20,6 20,3 
70 
E. Capacitor, C920 body 
34,8 34,7 36,0 36,7 
50 
Q901 heat-sink 
26,7 26,4 30,3 30,5 
Line filter, LF91 coil 
16,8 16,0 16,3 15,4 
60 *) 
PWB near D904 
17,3 16,7 17,5 17,0 
70 
PWB near Q901 
25,8 25,4 28,9 28,8 
70 
PWB near IC49 
35,2 35,4 36,0 36,1 
70 
Transformer, T901 coil 
34,8 34,7 36,7 36,7 
60 *) 
Transformer, T901 core 
31,9 31,8 33,8 33,9 
70 
PWB near D920 
47,8 48,2 49,5 50,2 
70 
Power cord bushing 
8,8 8,0 9,3 8,8 
60 
Switch button (Standby/on) 
4,8 5,0 5,4 4,7 
50 
Top enclosure above SMPS power 
7,2 6,8 7,5 7,2 
40 
Ambient 
23,3 
°C
 22,9 
°C
 21,5 
°C
 22,6 
°C
 
 
 
 
 
 
 
*) Minus 10K applied for thermo-couple method for windings 
**) Temperature rise limits for Singapore is 10K less. 
Tested in a test box under ventilation holes in top cover sides blocked condition. 
Page of 61