Harman Kardon DVD 29 (serv.man3) EMC - CB Certificate ▷ View online
- Page 30 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
- Page 31 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
N/A
L5.4
Marking and Instructions
No electronic flash
apparatus
apparatus
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.3.2 of IEC 60086-4
3 , unless comply with 6.3.2 of IEC 60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
- Page 32 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
No mains switch
—
Position of the functional switch (W) :
Functional switch “OFF” / 0,9W
—
Operating conditions
Functional switch “OFF” mode: at 50Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198
0,019 0,8 —
220
0,020 0,8 —
230
0,020 0,8 —
253
0,020 0,9 —
Functional switch “OFF” mode:
at 60Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198
0,019 0,7 —
220
0,020 0,8 —
230
0,022 0,9 —
242
0,022 0,9 —
253
0,022 0,9 —
Measured at DVD play mode: at 50Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198 0,158 14,2
—
220 0,147 14,3
—
230 0,143 14,3
—
253 0,134 14,4
—
Measured at DVD play mode: at 60Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198 0,149 14,1
—
220 0,141 14,3
—
230 0,136 14,3
—
242 0,131 14,3
—
253 0,127 14,3
—
- Page 33 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
Monitored point:
Δt measured
at 198V/50Hz
at 198V/50Hz
Δt measured
at 198V/60Hz
Δt measured
at 253V/50Hz
Δt measured
at 253V/60Hz
Limit dT (K)
**)
DVD Spindle motor case
9,7 9,6 10,2
9,8
-
D904 body
17,5 16,9 17,8 17,2
-
D920 body
49,8 49,8 51,4 51,9
-
IC49 body
49,0 49,1 49,8 49,7
-
IC24 body
49,3 49,4 49,7 50,8
-
IC19 body
43,0 43,5 43,7 43,0
-
E. Capacitor, C903 body
19,6 19,2 20,6 20,3
70
E. Capacitor, C920 body
34,8 34,7 36,0 36,7
50
Q901 heat-sink
26,7 26,4 30,3 30,5
-
Line filter, LF91 coil
16,8 16,0 16,3 15,4
60 *)
PWB near D904
17,3 16,7 17,5 17,0
70
PWB near Q901
25,8 25,4 28,9 28,8
70
PWB near IC49
35,2 35,4 36,0 36,1
70
Transformer, T901 coil
34,8 34,7 36,7 36,7
60 *)
Transformer, T901 core
31,9 31,8 33,8 33,9
70
PWB near D920
47,8 48,2 49,5 50,2
70
Power cord bushing
8,8 8,0 9,3 8,8
60
Switch button (Standby/on)
4,8 5,0 5,4 4,7
50
Top enclosure above SMPS power
7,2 6,8 7,5 7,2
40
Ambient
23,3
°C
22,9
°C
21,5
°C
22,6
°C
-
*) Minus 10K applied for thermo-couple method for windings
**) Temperature rise limits for Singapore is 10K less.
Tested in a test box under ventilation holes in top cover sides blocked condition.