Harman Kardon DVD 29 (serv.man3) EMC - CB Certificate ▷ View online
- Page 6 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test box
No require the ventilation
instructions, tested in the
test box.
instructions, tested in the
test box.
N/A
5 MARKING
Comprehensible and easily discernible
On top and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ................................... :
Maker:
Harman/Kardon
,
Model: DVD 29/230
See copy of marking plate.
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied
in according to IEC 60417-
5172.
in according to IEC 60417-
5172.
P
Rated supply voltage and symbol .......................... :
220-230V or 220V, and
AC-symbol (
~
) used
P
Frequency if safety dependant
50/60 Hz or 60Hz
P
Rated current or power consumption .................... :
15W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals
P
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus.
power to other apparatus.
P
5.3
Use of triangle with exclamation mark
Correct symbol applied:
imprinted on rear side in
connection with CAUTION
of opening. Further, no
incorrect use of this symbol
found.
imprinted on rear side in
connection with CAUTION
of opening. Further, no
incorrect use of this symbol
found.
P
- Page 7 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
Instructions for replacing lithium battery
No lithium battery in the
equipment
equipment
N/A
Instructions for modem if fitted
No modem
N/A
Class I earth connection warning
Class II apparatus
N/A
Instructions for multimedia system connection
Not applicable
N/A
Special stability warning for fixed installation
Not for fixed installation
N/A
Warning: battery exposure to heat
No battery
N/A
Warning: protective film on CRT face
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug is regarded as
disconnect device
disconnect device
P
Instructions for permanently connected equipment
Not permanently connected
equipment
equipment
N/A
- Page 8 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionising radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13 May
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
- Measure. w/length
(CD/DVD):
*) 791nm / 658nm
**) 792nm / 657nm
**) 792nm / 657nm
- Measured power (CD/DVD):
*) 43,0uW / 54,4uW
**) 48,2uW / 57,5uW
*) 43,0uW / 54,4uW
**) 48,2uW / 57,5uW
- AEL of Class 1 (CD/DVD):
*) 593uW / 390uW
**) 597uW / 390uW
*) 593uW / 390uW
**) 597uW / 390uW
Within AEL of Class 1 /
Class 1 Laser Product.
(Measured by JQA)
Note) For Laser Pick-up type,
*) SF-HD62FN (or FV)
**) SF-HD65
Class 1 Laser Product.
(Measured by JQA)
Note) For Laser Pick-up type,
*) SF-HD62FN (or FV)
**) SF-HD65
P
Emission limits under fault conditions .................... :
-
Measure. w/length
Measure. w/length
(CD/DVD):
*) 791nm / 658nm
**) 792nm / 657nm
**) 792nm / 657nm
-
Measured power (CD/DVD):
*) 292uW / 311uW
**) 225uW / 285uW
Measured power (CD/DVD):
*) 292uW / 311uW
**) 225uW / 285uW
- AEL of Class 1 (CD/DVD):
*) 593uW / 390uW
**) 597uW / 390uW
*) 593uW / 390uW
**) 597uW / 390uW
Within AEL of Class 1 /
Class 1 Laser Product (inside
)
(Measured by JQA)
Note) For Laser Pick-up type,
*) SF-HD62FN (or FV)
**) SF-HD65
Class 1 Laser Product (inside
)
(Measured by JQA)
Note) For Laser Pick-up type,
*) SF-HD62FN (or FV)
**) SF-HD65
P
- Page 9 of 40 -
Report
No.
89538
TRF No: IEC/EN 60065G
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
No fuse links operate during
normal operating operation.
(see appended table)
normal operating operation.
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
°
C