DOWNLOAD Harman Kardon DVD 23 (serv.man12) Service Manual ↓ Size: 1.82 MB | Pages: 65 in PDF or view online for FREE

Model
DVD 23 (serv.man12)
Pages
65
Size
1.82 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-23-sm12.pdf
Date

Harman Kardon DVD 23 (serv.man12) EMC - CB Certificate ▷ View online

 
 
Report No. JSH05110331-001 
Page 24 of 64 
5. Radiated emission 
 
Test result:   NA 
 
5.1 Radiated emission limit from frequency range 30MHz – 1000MHz 
 
Equipment type 
Source 
Frequency (MHz) 
Limit value dB(
µV/m) 
Quasi-peak 
Television receiver, 
video recorder and PC 
tuner cards 
Local Oscillator 
 
 
Other 
 
<=1000 
30 to 300 
300 to 1000 
30 to 230 
230 to 1000 
Fundamental            57* 
Harmonic                 52 
Harmonic                 56 
                                 40 
                                 47 
Television receiver, and 
receivers for broadcast 
satellite transmission, 
(except outdoor unit) 
Infrared remote control 
units and infrared 
headphone system 
Other 
 
30 to 230 
230 to 1000 
                                 40 
                                 47 
Frequency modulation 
sound receivers and PC 
tuner cards 
Local oscillator 
 
 
Other 
 
<=1000 
30 to 300 
300 to 1000 
.30 to 230 
230 to 1000 
Fundamental            60 
Harmonic                 52 
Harmonic                 56 
                                 40 
                                 47 
* in Japan, the limit 57dB
µV/m is relax to 66dBµV/m for operation channel <300MHz and to 70dBµV/m 
for operation channel >300MHz. 
 
 
 
5.2 Block diagram and test set up 
 
 
The measurement was applied in an semi-anchonic chamber.  
 
 
Report No. JSH05110331-001 
Page 25 of 64 
The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal metal 
ground plane. The turn table rotated 360 degrees to determine the position of the maximum emission 
level. The EUT was set 3 meters away from the receiving antenna, which was mounted on an antenna 
mask. The antenna moved up and down between from 1meter to 4 meters to find out the maximum 
emission level. 
Broadband antenna was used as receiving antenna. Both horizontal and vertical polarization of the 
antenna were set on measurement. In order to find the maximum emission, all of the interface cables 
were manipulated according to EN55022 requirement during radiated test. 
The bandwidth setting on R&S Test Receiver ESBI 40 was 120kHz. 
The frequency range from 30MHz to 1000MHz was checked. 
 
 
5.2.1  Photo For test Set-up
 
 
 
 
5.3 Test Protocol 
 
Temperature:  22 
°C 
 
Relative humidity :  
30% 
 
Polarization 
 
Frequency 
(MHz) 
Emission level 
(dBuV/m) 
Limits 
(dBuV/m) 
Margin 
(dBuV/m) 
30.0   40   
100.0   40   
200.0   40   
350.0   47   
600.0   47   
970.0   47   
Fundamental  
56 
 
 
 
 
Horizontal 
Harmonic  
52 
 
30.0   40   
71.5   40   
200.0   40   
350.0   40   
600.0   47   
970.0   47   
Fundamental  
56 
 
 
 
 
Vertical 
Harmonic  
52 
 
Note: * means margin >10dB. 
 
 
5.4 Emission waveform 
 
   
 
5.5 Measurement uncertainty 
 
The measurement  uncertainty describes the overall uncertainty of the given measured value   
during  the operation of the EUT. 
Measurement uncertainty is calculated in accordance with CISPR 16-4: 2002. 
Measurement uncertainty of mains terminal disturbance voltage : 
± 5.2dB 
The measurement uncertainty is given with a confidence of 95%, k=2. 
 
5.6 Additions, Deviations and Exclusions from Standards 
 
 None 
 
 
 
Report No. JSH05110331-001 
Page 26 of 64 
6. Harmonics 
 
Test   result: 
PASS 
 
 
6.1 Block Diagram of Test Setup 
 
 
 
 
 
 
 
 
6.2 Test Setup and Test Procedure 
 
Harmonics of the fundamental current were measured up to 40 order harmonics using a digital 
power  
meter with an analogue output and frequency analyser which was integrated in the harmonic & 
flicker  
test system. The measurements were carried out under steady conditions . 
 
 
 
The appliance has rated input power less than 75W, and is not luminaire , and according to the  
 
standards, no limit apply. 
 
6.2.1  Photo For test Set-up
 
 
 
6.3 Test Protocol 
Temperature  
°C   Relative 
Humidity  :  % 
 
 
 
6.4 Measurement Uncertainty  
 
The measurement uncertainty for harmonic test is under consideration according to CISPR 16- 
4:2002 
 
6.5 Additions, Deviations and Exclusions from Standards  
 
 None 
Harmonic & flicker 
test system 
     EUT 
 
 
Report No. JSH05110331-001 
Page 27 of 64 
7. Voltage Fluctuations-Flicker 
 
Test result 
PASS 
 
7.1 Block Diagram of Test Setup 
 
 
 
 
7.2 Test Setup and Test Procedure 
7.2.1 Definition 
 
Flicker:  
impression of unsteadiness of visual sensation induced by a lighting stimulus whose  
 
 
 
luminance or spectral distribution fluctuates with time. 
 
 
Pst:   
Short-term flicker indicator The flicker severity evaluated over a short period (in  
 
 
 
minutes); Pst=1 is the conventional  threshold of irritability  
 
Plt:   
long-term flicker indicator; the flicker severity evaluated over a long period (a few 
hous) 
 
 
 
Using successive Pst valuse. 
 
dc:   
the relative steady-state voltage change 
 
dmax: 
the maximum relative voltage change 
 
d(t):  
the value during a voltage change  
7.2.2  Photo For test Set-up 
Harmonic & flicker 
test system 
 
     EUT 
Page of 65
Display

Click on the first or last page to see other DVD 23 (serv.man12) service manuals if exist.