DOWNLOAD Harman Kardon DPR 2005 (serv.man3) Service Manual ↓ Size: 2.44 MB | Pages: 85 in PDF or view online for FREE

Model
DPR 2005 (serv.man3)
Pages
85
Size
2.44 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dpr-2005-sm3.pdf
Date

Harman Kardon DPR 2005 (serv.man3) EMC - CB Certificate ▷ View online

 
WOORI Technology Inc.                                                Page 7 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
 
3.6 Interface Cable 
         
Connection of EUT 
Cable Data 
RCA Jack 
RCA Cable, Shield 1.5m 
Speakers Non 
Shield 
1.0m 
S-Video Shield 
1.5m 
Headphone Shield 
2.0m 
A-BUS Non 
Shield 
2.0m 
Remote Shield 
1.5m 
RS-232C Shield 
2.0m 
 
 
 
 
4. Evaluation of Performance 
 
4.1 Measurement Uncertainty 
 
    Measurement uncertainty is calibrated in accordance with : 
        ●EMCIT document 93/30 
        ●NAMAS Information Sheet NIS81,Ed.1 May 1994 
(The treatment of uncertainties in EMC measurement). 
        The measurement uncertainty is not considered when deciding PASS or FAIL against the limit lines. 
        This means that “shared risk” (according to NAMAS publication NIS81 4.2) is used as option   
        Criterion. The argument for using this method, is that it is commonly accepted that the EMC limits   
        have already taken common good laboratory practice. 
 
4.2 Final Decision 
       
      The equipment under test complies to all requirements of the applied test standards.     
     
 
WOORI Technology Inc.                                                Page 8 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
5. Standards, Deviations And Results 
 
5.1 Applied Test Standards 
         
      The following standards have been applied: 
    ●EN 55013:2001
        Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and 
    Associated equipment 
Phenomena Basic 
Standards 
Result 
Mains terminal continuous disturbance voltage   
EN 55013: 2001 
Pass
 
Radio Interference Power 
EN 55013: 2001 
Pass 
Radiated Disturbance 
EN 55013: 2001 
Pass 
Antenna Terminal Disturbance Voltage 
EN 55013: 2001 
Pass 
 
EN 61000-3-2 :2000 : 
      Disturbances in supply systems caused by household appliances and similar electrical equipment 
  Phenomena Basic 
Standards 
Result 
Steady State Harmonics 
EN 61000-3-2:2000 
N/A 
Fluctuating Harmonics 
EN 61000-3-2:2000 
Pass 
 
EN 61000-3-3:1995+A1: 2001 
      Disturbances in supply systems caused by household appliances and similar electrical equipment 
Phenomena Basic 
Standards 
Result 
Flicker 
EN 61000-3-3:1995+A1: 2001 
Pass 
Voltage Fluctuations 
EN 61000-3-3:1995+A1: 2001 
N/A 
 
5.2 Deviations And Evaluations 
 
        ●No recorded deviations to the applied standards. 
        ●No general evaluations made. 
 
WOORI Technology Inc.                                                Page 9 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
6. Mains Terminal Continuous Disturbance Voltage   
 
6.1 Test Procedure 
     
 
    The measurements were performed in a shielded enclosure. EUT was connected to an Artificial Mains 
Network (AMN). EUT was placed on a wooden table 0.8m above the grounded floor and at least 0.4m from 
the reference ground plane(wall), EUT was placed at least 0.8m from, and connected via a 1m mains cable, 
to the AMN.   
The output power of the amplifier was set to 1/8 of rated power at 8ohms load. 
        The measurements on the terminals for mains connection were conducted between neutral and ground, and 
between phase and ground, in the frequency range 150kHz to 30MHz. 
        A peak detector scan was conducted over the defined frequency range on all phases. A comparison of the 
results obtained from the different phases was then conducted to find the most emitting phase for each 
frequency.    This “Worst Case” scan with peak detector is presented detector. 
        Instrumentation used during this session: 
 
Instruments Manufacturer 
Model 
Serial number
Due To Calibration 
Test Receiver   
R&S 
ESCS30 833364/020 2004. 
09 
Artificial Mains Network 
R&S 
ESH3-Z5 
833874/006 
2004. 10 
 
6.2 Measurement Uncertainty 
 
    Mains terminal disturbance voltage measurement         : ±3.0dB 
 
6.3 Test Parameters 
 
Port: 
AC Mains
 
Test Engineer: 
J. Y. Yu 
Basic Standard: 
EN55013: 2001 
 
Frequency Range: 
150kHz – 30MHz 
Frequency Step: 
5kHz 
IF Bandwidth: 
9kHz 
Measurement Time: 
0.2 Sec 
 
6.4 Test Data 
 
    1-1)  Tuner FM 98.0 MHz  7-CH Stereo Mode  (Ground) 
   
Frequency
(MHz)
Q-Peak
Average
Q-Peak
Average
Q-Peak
Average
0.46
32.7
32.3
N
56.7
46.7
24.0
14.4
0.77
33.7
31.7
L1
56.0
46.0
22.3
14.3
3.74
38.3
37.8
N
56.0
46.0
17.7
8.2
4.27
35.1
34.6
N
56.0
46.0
20.9
11.4
9.21
41.9
35.4
N
60.0
50.0
18.1
14.6
17.98
41.8
32.1
L1
60.0
50.0
18.2
17.9
Line
Limit (dB)
Reading Value (dB)
Margin (dB)
 
 
WOORI Technology Inc.                                                Page 10 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
 
1-2)    Tuner FM 98.0 MHz    7-CH Stereo Mode (Non Ground) 
   
Frequency
(MHz)
Q-Peak
Average
Q-Peak
Average
Q-Peak
Average
0.38
30.3
29.4
L1
58.2
48.2
27.9
18.8
1.64
35.9
33.0
L1
56.0
46.0
20.1
13.0
2.11
39.2
36.6
N
56.0
46.0
16.8
9.4
4.26
30.9
30.5
L1
56.0
46.0
25.1
15.5
17.43
44.4
33.0
L1
60.0
50.0
15.6
17.0
18.09
42.9
33.0
L1
60.0
50.0
17.1
17.0
Line
Limit (dB)
Reading Value (dB)
Margin (dB)
 
 
2-1)  DVD  7-CH Stereo Mode  (Audio 1 kHz Signal IN)  (Ground) 
 
Frequency
(MHz)
Q-Peak
Average
Q-Peak
Average
Q-Peak
Average
0.38
37.4
36.2
N
58.2
48.2
20.8
12.0
3.07
38.5
31.2
L1
56.0
46.0
17.5
14.8
3.64
39.0
36.9
L1
56.0
46.0
17.0
9.1
4.16
36.8
35.1
L1
56.0
46.0
19.2
10.9
14.46
38.3
36.5
L1
60.0
50.0
21.7
13.5
15.41
37.0
35.8
L1
60.0
50.0
23.0
14.2
Line
Reading Value (dB)
Limit (dB)
Margin (dB)
 
 
2-2)  DVD  7-CH Stereo Mode  (Audio 1 kHz Signal IN)  (Non Ground) 
 
Frequency
(MHz)
Q-Peak
Average
Q-Peak
Average
Q-Peak
Average
0.38
38.8
37.6
N
58.2
48.2
19.4
10.6
1.57
36.9
36.9
L1
56.0
46.0
19.1
9.1
2.18
40.5
36.6
L1
56.0
46.0
15.5
9.4
2.57
41.6
38.3
L1
56.0
46.0
14.4
7.7
4.15
34.2
29.9
L1
60.0
50.0
25.8
20.1
14.45
39.2
37.4
L1
60.0
50.0
20.8
12.6
Line
Reading Value (dB)
Limit (dB)
Margin (dB)
 
 
*) Measurement graphs can be found in the 
Appendix A.
 
 
 
Comment 
        If no frequencies are specified in the tables, no measurement for quasi-peak or average was necessary. 
 
       
Result 
 Compliant 
Page of 85
Display

Click on the first or last page to see other DPR 2005 (serv.man3) service manuals if exist.