DOWNLOAD Harman Kardon DPR 2005 (serv.man2) Service Manual ↓ Size: 3.2 MB | Pages: 118 in PDF or view online for FREE

Model
DPR 2005 (serv.man2)
Pages
118
Size
3.2 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dpr-2005-sm2.pdf
Date

Harman Kardon DPR 2005 (serv.man2) EMC - CB Certificate ▷ View online

 
WOORI Technology Inc.                                                Page 13 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
10.3  Test Log 
 
Point Voltage 
Coupling 
Result 
(Pass/Fail)
 HCP 
±4kV Contact 
Discharge 
Pass 
 VCP 
±4kV Contact 
Discharge 
Pass 
 Screws 
±4kV Contact 
Discharge 
Pass 
  Top, Rear, Sides 
±4kV Contact 
Discharge 
Pass 
 RCA Jack 
±4kV Contact 
Discharge 
Pass 
 RS-232 
±4kV Contact 
Discharge 
Pass 
 Front, Knobs 
±8kV Air 
Discharge 
Pass 
 Power Cord Bushing 
±8kV Air 
Discharge 
Pass 
 Headphone, A-BUS 
±8kV Air 
Discharge 
Pass 
 Remote 
±8kV Air 
Discharge 
Pass 
 
 
Comment/Performance 
No operation errors were detected during or after the discharges 
 
Result 
Compliant 
 
WOORI Technology Inc.                                                Page 14 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
 
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (ENV 50204) 
 
11.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
 
The tests were performed at 3m distance in an anechoic chamber.
 
For floor-standing equipment, the EuT was standing on the floor, isolated from the ferrite core.
 
For tabletop equipment, the EuT was located on a wooden table 0.8m above the floor.
 
The EuT was exposed to the field from different angles, normally 0。, 90。,180。,270。 and 360。
 
and at both horizontal and vertical polarization (antenna height 1.5m).
 
A signal level of 3V/m, 50% PM modulated with a 200Hz was applied in the frequency range
 
895 - 905MHz.
 
 
Instrumentation used during this session: 
 
Instruments 
Manufacturer
Model 
Serial Number 
Due to Calibration
Signal Generator
 
R & S
 
SMY01
 
1062.5502.11
 
2004. 12 
Power Amplifier
 
Noiseken
 
NA25MF1G2010C
 
A00518
 
2005. 02 
Power Sensor
 
HP
 
8482A
 
U537293323
 
2005. 02 
Power Meter
 
HP
 
E4419B
 
GB39511164
 
2005. 04 
Biconical log Antenna
 
ARA
 
LPB-2520/A
 
1180
 
2005. 02 
Wideband field probe
 
Chase
 
EMC-20
 
2244190.2
 
2005. 03 
 
11.2 Test Parameters 
 Port: 
Enclosure 
 
Test Engineer: 
J. Y. Yu 
 Basic Standard:  EN 61000-4-3:1995 
 
Performance Criteria: 
 Dwell Time : 
3 Sec 
 
Frequency Step : 
1% 
Modulation : 
50% Duty PM @ 200 Hz 
Frequency Range : 
895-905 MHz 
 Test Level 
3 Vrms 
 
 
 
 
 
 
 
 
 
WOORI Technology Inc.                                                Page 15 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
11.3  Test Log 
 
Frequency Range 
( MHz ) 
Position 
(Angle) 
Polarity 
(H or V)
Field Strength
( Vrms ) 
Modulation 
Result  
(Pass/Fail)
895 - 905
 
Front
 
Η
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Rear
 
Η
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Right
 
Η
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Left
 
Η
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Front
 
V
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Rear
 
V
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Right
 
V
 
3
 
50% PM (200 Hz)
 
Pass 
895 - 905
 
Left
 
V
 
3
 
50% PM (200 Hz)
 
Pass 
 
 
Comment/Performance 
No operation errors were detected during or after the discharges 
 
Result 
Compliant 
 
WOORI Technology Inc.                                                Page 16 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
12. Fast Transients/Burst (EN 61000-4-4) 
 
12.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
A ground reference plane was located on the floor, and connected to earth via a low impedance connection. 
The EFT/Burst generator's reference ground was connected to the reference plane. In case of a floor 
a floor standing equipment, EUT was placed on the reference plane on 10cm of insulating support. 
In case of table-top equipment, EUT was placed on a wooden table 0.8m above the reference plane. 
Burst were fired at ±1kV to each single line at the AC and DC mains, and ±0.5kV was applied to signal 
cables using a capacitive coupling clamp. 
 
Instrumentation used during this session: 
Instruments 
Manufacturer
Model 
Serial Number  Due to Calibration
 EFT/Burst Simulator 
Noiseken 
FNS-AXⅡ850
0199B01147 
2005. 02 
 Clamp 
Noiseken 
FNS-AXⅡ850
N/A 
2005. 02 
 
12.2 Test Parameters 
    Port :
 
AC Mains
 
 
Test Engineer: 
J. Y. Yu 
  Basic Standard :
 
EN 61000-4-4:1995
 
 
Performance Criteria: 
  Duration :
 
120 Sec
 
±8kV 
 
 
    Test Data :
 
Tr/Th   5/50ms   Fburst   5 kHz    Trep   300mS 
 
12.3  Test Log 
 
Line Voltage 
Coupling 
Inject Time 
( Sec ) 
Result  
(Pass/Fail) 
L1 
0.5, 1 kV 
Direct 
120 
Pass 
L2 
0.5, 1 kV 
Direct 
120 
Pass 
L1+ L2 
0.5, 1 kV 
Direct 
120 
Pass 
 
Comment/Performance 
No operation errors were detected during or after the discharges 
 
Result 
Compliant 
Page of 118
Display