Harman Kardon DPR 2005 (serv.man2) EMC - CB Certificate ▷ View online

 
WOORI Technology Inc.                                                Page 5 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
2. Equipment Under Test ( EUT) 
 
2.1 Identification of EUT
 
       
Category:
 
AV Receiver 
Model Name:
 
DPR2005 
Brand Name:
 
Harman Kardon 
External Signal in/out: 
Audio INOUT (24), 8CH Direct IN (8), Pre-OUT (8), 
 
Digital Coaxial IN/OUT (4), Component Video IN/OUT (3), 
 
S-Video IN/OUT (9), Composite Video IN/OUT (9), 
 
Remote IN/OUT (2), Multi Room (1), RS-232 (1), A-BUS (1), 
 
Antenna FM/AM (2), Speaker (7), Headphone (1) 
Serial Number:
 
N/A
 
Voltage:
 
AC 230V, 50Hz
 
Power:
 
1100 W (Max.), 200W (1/8W) 
Remarks:
 
 
 
2.2 Variants Covered By This Report
 
     
 
ID No. 
Model Name 
Technical Deviations From Reference Model 
N/A N/A 
 
 
2.3 Modifications
 
●No modifications. 
   
2.4 Additional Information Related To Testing 
●No comment 
   
2.5 Picture Documentation 
      ●Pictures can be found in 
Appendix F.
 
 
WOORI Technology Inc.                                                Page 6 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
3. TEST SPECIFICATIONS 
 
3.1 Standards 
   EN55 020(2002) : Electromagnetic immunity of broadcast receivers and associated equipment. 
 
3.2 Additions, deviations and exclusions from standards 
      No additions, deviations or exclusions have been made from standard. 
 
3.3 Purpose of the test 
      Purpose of test: To determine whether the equipment under test fulfils the EMC immunity   
      requirements of the standard stated in section 3.1 
 
3.4 Test site location 
    ANAM Electronics Co., Ltd. 
   Nemko korea Co., Ltd. 
   3.4.1 Location 
     645, Sungkok-dong, Ansan-City, Kyungki-Do, 425-110, Korea 
 
        This test site has been accredited to EMC TBM (EN 55013, EN55020) test site by Nemko. 
    The AUT. No. is : 357 
 
4. TEST SUMMARY 
      The results in this report apply only to sample tested : 
Test 
Passed the test 
Note 
    Input immunity to RF voltages (S1) 
 
Yes  
    Immunity to RF voltages (S2a)
 
Yes  
    Immunity to RF voltages(in common mode) (S2b)
 
Yes  
    Immunity to ambient electromagnetic fields (S3)
 
Yes  
  Screening effectiveness (S4)
 
Yes  
 
Test 
Passed the test 
 Electrostatic Discharge (EN 61000-4-2) 
 
Yes 
  Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test 
 
(EN 61000-4-3) 
 
Yes
 
 Electrical Fast Transients/Burst (EN 61000-4-4) 
 
Yes 
 
The equipment does comply with the requirements 
 
Measurement data see Annex A, B, C, D and E. 
 
 
WOORI Technology Inc.                                                Page 7 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
5. Input immunity to RF voltages (in Differential mode) (S1) 
 
5.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature 
20  ℃ 
 
Relative Humidity 
40 % 
 
      The criterion concerning acceptable sound interference is a wanted to unwanted   
   audio signal ratio of ≥40 dB at a wanted signal level of 50 mW. 
 
      The EUT was placed 0.1m above a metallic ground plane of dimensions 2 x 1 m. 
      The measuring set-up was shown in Figure 1 EN55020 (2002). 
      The principle of operation was similar to the measuring set-up of Figure 1 EN55020 (2002). 
       
      The low pass filter was added to prevent influence of the measuring results by 
      harmonics of the unwanted signal generators. 
 
      The lineout of the EUT were applied to an 22k ohm purely resistive road (Ro
      and then to the AF inputs of the test system. 
      The power supply of the EUT was connected to a standard voltage source 
   (without special filters). 
   The measurements were performed with test software TS9980 Ver.2.9. 
 
5.2 Measurement uncertainty 
 
    Antenna input immunity +/- 2.0dB 
 
5.3 Test result of input immunity to RF voltages. 
 
        The equipment does comply with the requirements. 
 
    For the measurement data, see Annex A 
 
 
WOORI Technology Inc.                                                Page 8 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
6. Immunity to RF voltages (S2a) 
 
6.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature 
20  ℃ 
 
Relative Humidity 
40 % 
 
      The EUT was placed 0.1m above a metallic ground plane of dimensions 2 x 1m. 
      The wanted signal was fed to all input terminals respectively and the unwanted   
      signal was fed to mains input, audio output and input terminals respectively. 
 
      The criterion concerning acceptable sound interference is a wanted to unwanted   
   audio signal ratio of ≥40 dB at a wanted signal level of 50 mW. 
 
      The audio output power was measured with a 0.5 - 3 kHz band-pass filter. 
      The audio analyzer was applied without a weighting filter. 
      The ground connection of the input matching network (Rci), output matching network 
      (Rco), and mains filter (MSF) were directly connected to the metal table. 
   The mains filter (MSF) was connected to ground while the other matching networks 
      are only connected to ground when they are being used as injection ports. 
 
   The measurements were performed with test software TS9980 Ver.2.9. 
 
6.2 Measurement uncertainty 
 
        Immunity to conducted currents : +/- 2dB 
 
6.3 Test result immunity to conducted voltage. 
 
        The equipment does comply with the requirements. 
 
    For the measurement data, see Annex B 
 