DOWNLOAD Harman Kardon DPR 1005 (serv.man14) Service Manual ↓ Size: 8.82 MB | Pages: 127 in PDF or view online for FREE

Model
DPR 1005 (serv.man14)
Pages
127
Size
8.82 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dpr-1005-sm14.pdf
Date

Harman Kardon DPR 1005 (serv.man14) EMC - CB Certificate ▷ View online

 
WOORI Technology Inc.                        Page 104 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
Screen Effectiveness Test 
 
Port: Coaxial Antenna Terminal 
Wanted signal 
Frequency (MHz) 
Unwanted signal 
Frequency (MHz) 
Level 
dB 
Fm
a
 Fm
a
  ±0.001 
20 
 
 ** Fm
= 98.0MHz 
 
 
Procedure 
The screening effectiveness Se is given by the formula: 
 
       Se = Aa + Ac - A 
 
Aa
    is the setting of the variable attenuator expressed in dB; 
Ac
    is the insertion loss of the signal combiner and matching network expressed in dB; 
A
      is the insertion loss of the absorbing clamp expressed in dB. 
 
 
Protocol 
Frequency
Unwanted Result
EUT
Signal
 Frequency
98.001 MHz
45.6 dB
13.5 dB
17.5 dB
41.6 dB
Pass
97.999 MHz
44.3 dB
13.5 dB
17.5 dB
40.3 dB
Pass
Screening
Effectiveness
( Se )
Clamp
Loss
Variable
Attenuation
Combiner &
Matching
98.0 MHz
 ( Aa )
 
Loss 
( Ac )
( A )
 
 
 
 
WOORI Technology Inc.                                                Page 2 of 83 
                               DPR1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMI 
 
Contents of This Report
 
 
1. CLIENT 
INFORMATION 
 
1.1 Applicant   
 
 
1.2 Manufacturer 
 
 
1.3 Other Information 
 
 
 
 
2. EQUIPMNET 
UNDER 
TEST(EUT) 
 
2.1 Identification of EUT 
 
 
2.2 Variants Covered By This Report 
 
 
2.3 Modifications 
 
 
2.4 Additional Information Related to Testing 
 
 
2.5 Picture Documentation 
 
 
 
 
3. GENERAL 
TEST 
CONDITIONS 
 
3.1 Location 
 
 
3.2 Operating Environment 
 
 
3.3 Operating During Test 
 
 
3.4 Test Equipment 
 
 
3.5 Support Equipment 
 
 
 
 
4. 
EVALUATION OF PERFORMANCE 
 
4.1 Measurement Uncertainty 
 
 
4.2 Final Decision 
 
 
 
 
5. 
STANDARDS, DEVIATIONS AND RESULTS 
 
5.1 Applied Test Standards 
 
 
5.2 Deviations And Evaluations 
 
 
 
 
6. 
MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 
 
6.1 Test Procedure 
 
 
6.2 Measurement Uncertainty 
 
 
6.3 Test Parameters 
 
 
6.4 Test Data 
 
 
 
 
7. 
RADIO INTERFERENCE POWER 
12 
 
7.1 Test Procedure 
 
 
7.2 Measurement Uncertainty 
 
 
7.3 Test Parameters 
 
 
7.4 Test Data 
 
 
WOORI Technology Inc.                                                Page 3 of 83 
                               DPR1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMI 
 
 
 
 
 
 
8 RADIATED 
DISTURBANCE 
16 
 
8.1 Test Procedure 
 
 
8.2 Measurement Uncertainty 
 
 
8.3 Test Parameters 
 
 
8.4 Test Data 
 
 
 
 
9. ANTENNA 
TERMINAL 
DISTURBANCE 
VOLTAGE 
19 
 
9.1 Test Procedure 
 
 
9.2 Measurement Uncertainty 
 
 
9.3 Test Parameters 
 
 
9.4 Test Data 
 
 
 
 
10. FLUCTUATING 
HARMONICS 
22 
 
10.1 Test Procedure 
 
 
10.2 Test Parameters 
 
 
10.3 Fluctuating Harmonics, Graphic Presentation 
 
 
 
 
11. FLICKER 
23 
 
11.1 Test Procedure 
 
 
11.2 Test Parameters 
 
 
11.3 Flicker Propability (Pst), Graphic Presentation 
 
 
 
 
APPENDIXES 
 
APPENDIX A  Measurement Graphs of Mains Terminal Disturbance Voltage 
24 
APPENDIX B    Measurement Graphs of Radio Interference Power 
37 
APPENDIX C    Measurement Graphs of Fluctuating Harmonics 
64 
APPENDIX D    Measurement Graphs of Flicker 
67 
APPENDIX E  Photographs of Test 
69 
APPENDIX F    Photographs of EUT 
76 
APPENDIX G  Circuit Diagram 
87 
APPENDIX H  Schematic Diagrams 
88 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other DPR 1005 (serv.man14) service manuals if exist.