Harman Kardon BDS 280 (serv.man4) EMC - CB Certificate ▷ View online
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 13 of 401
3. POWER LINE CONDUCTED EMISSION TEST
3.1. Test Equipments
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal. Cal. Interval
1. Test Receiver Rohde & Schwarz
ESHS10
838693/001
Oct.31, 12
1 Year
2.
L.I.S.N.#1
Rohde & Schwarz ESH2-Z5
834066/011
Oct.31, 12
1 Year
3.
L.I.S.N.#3
Kyoritsu
KNW-242C
8-1920-1
May.08, 13
1 Year
4. Terminator Hubersuhner
50
Ω
No. 1
May.08, 13
1 Year
5. Terminator Hubersuhner
50
Ω
No. 2
May.08, 13
1 Year
6.
RF Cable
Fujikura
3D-2W
No.1
May.08, 13
1Year
7. Coaxial Switch
Anritsu
MP59B
M50564
May.08, 13
1 Year
8. Pulse Limiter Rohde & Schwarz ESH3-Z2
100341
May.08, 13
1 Year
9.
Signal Generator
HP
8648A
3636A02081 May.08, 13
1 Year
3.2. Block Diagram of Test Setup
3.3. Test Standard
EN55022: 2010+AC: 2011(Class B) and EN 55013: 2001+A1: 2003+A2:2006
3.4. Power Line Conducted Emission Limit
Limits dB(
μV)
Frequency
MHz
Quasi-peak Level
Average Level
0.15 ~
0.50
66 ~ 56*
56 ~ 46*
0.50 ~
5.00
56
46
5.00 ~ 30.00
60
50
Notes: 1. *Decreasing linearly with logarithm of frequency.
2. The lower limit shall apply at the transition frequencies.
3.5. EUT Configuration on Test
The following equipments are installed on conducted emission test to meet EN55013 and
EN55022 requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
EN55022 requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
3.5.1. BLU-RAY DISC SYSTEM
Model Number
: BDS580
Serial Number
: N/A
3.5.2. Support Equipment : As Tested Supporting System Detail, in Section 2.2.
EUT
Peripheral
LISN #1
LISN #3
PC System
80cm
Receiver
:50
Ω Terminator
0.8m
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 14 of 401
3.6. Operating Condition of EUT
3.6.1. Setup the EUT and simulators as shown in Section 3.2.
3.6.2. Turn on the power of all equipments.
3.6.3. Let the EUT work in test modes (HDMI IN / OPTICAL IN / AUX IN / COAXIAL
3.6.2. Turn on the power of all equipments.
3.6.3. Let the EUT work in test modes (HDMI IN / OPTICAL IN / AUX IN / COAXIAL
IN / FM 98MHz / iPod (USB) Play / BD Play/ BD Live / Wi-Fi Mode) and test it.
3.7. Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1).The other peripheral devices power cord connected to the power mains
through a line impedance stabilization network (L.I.S.N.#3). This provided a 50ohm
coupling impedance for the tested equipments. Both sides of AC line are checked to find
out the maximum conducted emission levels according to the EN55013 and EN55022
regulations during conducted emission test.
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 3.8.
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1).The other peripheral devices power cord connected to the power mains
through a line impedance stabilization network (L.I.S.N.#3). This provided a 50ohm
coupling impedance for the tested equipments. Both sides of AC line are checked to find
out the maximum conducted emission levels according to the EN55013 and EN55022
regulations during conducted emission test.
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 3.8.
3.8. Power Line Conducted Emission Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
The EUT with the following test modes were tested and selected (mode 1 ~14) to read Q.P
values, all the test results are listed in next pages.
The EUT with the following test modes were tested and selected (mode 1 ~14) to read Q.P
values, all the test results are listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model No. : BDS580
Test Date: Jun.05~06, 2013 Temperature: 26.1℃ Humidity: 65%
The details of test modes are as follows:
Test Date: Jun.05~06, 2013 Temperature: 26.1℃ Humidity: 65%
The details of test modes are as follows:
Reference Test Data No.
No. Test
Mode
Line
Neutral
1. BD
Play
#1
#2
2. FM
98MHz(UNGND)
#3
#4
3.※
FM 98MHz(GND)
#5
#6
4.
AUX In 1
#9
#10
5.
AUX In 2
#8
#7
6.
HDMI In 1
#16
#15
7.
HDMI In 2
#13
#14
8.
HDMI In 3
#12
#11
9.
Optical In 1
#17
#18
10.
Optical In 2
#20
#19
11. Coaxial
In
#21
#22
12.
iPod (USB) Play
#24
#23
13. Wi-Fi
Mode
#25
#26
14. BD
Live
#28
#27
(※ Worst test mode)
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 15 of 401
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E13288 page 16 of 401
Click on the first or last page to see other BDS 280 (serv.man4) service manuals if exist.