DOWNLOAD Harman Kardon BDS 277 (serv.man2) Service Manual ↓ Size: 13.97 MB | Pages: 127 in PDF or view online for FREE

Model
BDS 277 (serv.man2)
Pages
127
Size
13.97 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
bds-277-sm2.pdf
Date

Harman Kardon BDS 277 (serv.man2) EMC - CB Certificate ▷ View online

R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377      page 13 of 323 
 
2.5. Measurement Uncertainty(95% confidence levels, k=2) 
Test Item 
Uncertainty 
Uncertainty for Conduction emission test
in No. 1 Conduction 
3.2 dB(150kHz to 30MHz) 
3.6dB (30~200MHz, Polarize: H) 
3.8dB (30~200MHz, Polarize: V) 
3.8dB (200M~1GHz, Polarize: H) 
Uncertainty for Radiation Emission test 
in 10m chamber (Distance: 10m) 
3.8dB (200M~1GHz, Polarize: V) 
3.6 dB (30~200MHz, Polarize: H) 
3.8dB (30~200MHz, Polarize: V) 
4.2dB (200M~1GHz, Polarize: H) 
Uncertainty for Radiation Emission test 
in 3m chamber 
3.8dB (200M~1GHz, Polarize: V) 
3.1dB (Distance: 3m Polarize: V) 
Uncertainty for Radiation Emission test in 
3m chamber (1GHz-18GHz) 
3.7 dB (Distance: 3m Polarize: H) 
2.4dB (Distance: 3m Polarize: V) 
Uncertainty for SVSWR in 10m Chamber
2.4 dB (Distance: 3m Polarize: H) 
Uncertainty for Flicker test 
0.06% 
Uncertainty for Harmonic test 
1.8% 
1.36dB (Using CDN test) 
Uncertainty for C/S Test 
3.20 (Using EM clamp test) 
1.64 dB (80MHz~200MHz) 
Uncertainty for R/S Test 
1.66 dB(200MHz~1000MHz) 
EN 55020 S3 
0.54 dB 
0.6℃ 
Uncertainty for test site temperature and 
humidity 
3% 
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377      page 14 of 323 
 
 
3.  POWER LINE CONDUCTED EMISSION TEST 
3.1. Test Equipments 
Item  Equipment 
Manufacturer 
Model No.  Serial No. 
Last Cal. 
Cal. Interval
1.  Test Receiver Rohde & Schwarz
ESHS10 
838693/001  Oct.31, 11 
1 Year 
2. 
L.I.S.N.#1 
Rohde & Schwarz ESH2-Z5 
834066/011  Oct.31, 11 
1 Year 
3. 
L.I.S.N.#3 
Kyoritsu 
KNW-242C
8-1920-1 
May.08, 12 
1 Year 
4. Terminator  Hubersuhner 
50
Ω 
No. 1 
May.08, 12 
1 Year 
5. Terminator  Hubersuhner 
50
Ω 
No. 2 
May.08, 12 
1 Year 
6. 
RF Cable 
Fujikura 
3D-2W 
No.1 
May.08, 12 
1Year 
7.  Coaxial Switch
Anritsu 
MP59B 
M50564 
May.08, 12 
1 Year 
8. 
Pulse Limiter Rohde & Schwarz ESH3-Z2 
100341 
May.08, 12 
1 Year 
9. 
Oscilloscope
Tektronix 
TDS3052B
B026036 
May.20, 12 
1 Year 
3.2. Block Diagram of Test Setup 
 
3.3. Test Standard 
EN55022: 2010 (Class B) and EN 55013: 2001+A1: 2003+A2:2006 
3.4. Power Line Conducted Emission Limit 
Limits dB(
μV) 
 Frequency 
MHz 
Quasi-peak Level 
Average Level 
0.15  ~
0.50 
66 ~ 56* 
56 ~ 46* 
0.50 ~
5.00 
56 
46 
5.00 ~ 30.00 
60 
50 
Notes: 1. *Decreasing linearly with logarithm of frequency. 
 2. The lower limit shall apply at the transition frequencies. 
EUT
Peripheral 
LISN#1
LISN#3
PC System 
80cm
Receiver
:50
Ω Terminator 
0.8m
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377      page 15 of 323 
 
3.5. EUT Configuration on Test 
The following equipments are installed on conducted emission test to meet EN55013 and 
EN55022 requirement and operating in a manner which tends to maximize its emission 
characteristics in a normal application. 
3.5.1.BLU-RAY DISC SYSTEM 
Model Number   
   :   BDS575 
Serial Number 
   :   N/A 
3.5.2.Support Equipment      :  As Tested Supporting System Detail, in Section 2.2. 
3.6. Operating Condition of EUT 
3.6.1.Setup the EUT and simulators as shown in Section 3.2. 
3.6.2.Turn on the power of all equipments. 
3.6.3. Let the EUT worked in test mode (BD Play/USB Play/BD Live/FM Mode/Coaxial In/ 
AUX In / Component Video IN/ Optical In / HDMI In) and test it. 
3.7. Test Procedure 
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT 
Power connected to the power mains through a line impedance stabilization network 
(L.I.S.N. #1).The other peripheral devices power cord connected to the power mains 
through a line impedance stabilization network (L.I.S.N.#3). This provided a 50ohm 
coupling impedance for the tested equipments. Both sides of AC line are checked to find 
out the maximum conducted emission levels according to the EN55013 and EN55022 
regulations during conducted emission test. 
 
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz. 
 
The frequency range from 150kHz to 30MHz is checked. The test result are reported on 
Section 3.8.   
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377      page 16 of 323 
 
3.8. Power Line Conducted Emission Test Results 
PASS. (All emissions not reported below are too low against the prescribed limits.) 
 
The EUT with the following test modes were tested and selected (mode 1~10) to read Q.P 
values, all the test results are listed in next pages. 
 
EUT: BLU-RAY DISC SYSTEM      Model No. : BDS575 
 
Test Date: Jun.29, 2012      Temperature: 25.5℃                Humidity: 55% 
The details of test modes are as follows: 
 
Reference Test Data No. 
No. Test 
Mode 
 Line 
Neutral 
1.  
BD Play  
#7 #6 
2. 
USB Play 
#5 
#4 
3.   
 BD Live 
#2 
#3 
4. Coaxial 
In 
#12 
#13 
5. Optical 
In 
#15 
#14 
6. 
Component Video In 
#16 
#17 
7. AUX 
In 
#9 
#8 
8.  
HDMI In 
#11 
#10 
9. FM 
98MHz(UNGND)
#18 
#19 
10. FM 
98MHz(GND) 
#21 
#20 
  (※ Worst test mode) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other BDS 277 (serv.man2) service manuals if exist.