WOORI Technology Inc.                                                Page 24 of 92 
                               AVR7300 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 318.EMI 
 
10. Fluctuating Harmonics (EN 61000-3-2) 
 
10.1 Test Procedure 
         
        EUT was connected to the Power Analyzer system. Measurements were conducted on all active phases, 
for harmonics 1-40th of the mains frequency (50 or 60Hz). A pure AC mains was supplied to the 
system from two power supply units. The units supply an AC mains, free of harmonics or distortion of 
any kind. An overview of the harmonic emission is presented as numerics and as graphics. 
     Instrumentation used during this session: 
 
Instruments Manufacturer 
Due 
To 
Calibration 
Profline 2100 System 
Schaffner 
2004. 09 
 
10.2 Test Parameters
 
 
Port: 
AC Mains 
Test Engineer: 
J. Y. Yu 
Basic Standard: 
EN 61000-3-2:2000 
 
 
 
10.3 Fluctuating Harmonics, Graphic Presentation 
 
        Measurement results can be found in the 
Appendix C
 
       
Result 
       
Compliant  
 
10.4 Remarks 
 
Speaker Output Conditions 
 
Power 
Consumption
Speaker Channel
L
31.32
V
11.11
V
8  ohm
Front
R
31.56
V
11.20
V
8  ohm
Speaker Channel
L
31.49
V
11.17
V
8  ohm
Rear
R
31.02
V
11.01
V
8  ohm
Speaker Center
31.43
V
11.13
V
8  ohm
Speaker Channel
L
30.04
V
10.66
V
8  ohm
Rear Back
R
30.32
V
10.76
V
8  ohm
Speaker 
Pmax. 
Channel
1,460 W
1/8 Pmax. 
610 W
Impedance
 
 
 
 
 
WOORI Technology Inc.                                                Page 25 of 92 
                               AVR7300 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 318.EMI 
 
11. Flicker (EN 61000-3-3) 
 
11.1 Test Procedure
 
 
        EUT was connected to the Power Analyzer system. Measurements were conducted to obtain the desired       
flicker parameters. The measuring time depends on which parameters are to be measured: 
          ◆  2 hours for Long Time Flicker assessment (Plt) 
          ◆  10 minutes for Short Time Flicker assessment (Pst) 
          ◆  1-10 minutes for Dmax, Dc and Dt assessment (depending on EUT switch-rate) 
        A pure AC mains was supplied to the system from two power supply units. The units supply an AC mains, 
free of harmonics, fluctuations or distortion of any kind. A defined impedance was located      between 
the supply unit and the EUT. 
        A measurement table and a graphic presentation of the “Worst Case” propability function of Short 
Time 
    Flicker during this session(if measured) are presented in the report. 
        Instrumentation used during this session: 
 
Instruments Manufacturer 
Due 
To 
Calibration 
Profline 2100 System 
Schaffner 
2004. 09 
 
11.2 Test Parameters
 
         
Port: 
AC Mains 
 
 
Basic Standard: 
EN 61000-3-3:1995+A1: 2001 
Test Engineer: 
J. Y. Yu 
Measured:   
Dmax              Dc 
Dt                Pst 
Plt 
 
11.3 Flicker Propability(Pst), Graphic Presentation 
 
        Measurement results can be found in the 
Appendix D.
 
 
       
Result 
        Compliant
 
 
WOORI Technology Inc.                                                Page 26 of 92 
                               AVR7300 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 318.EMI 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Appendix
 A 
 
Measurement Graphs of 
Mains Terminal Disturbance Voltage 
 
 
 
 
 
 
 
 
 
 
WOORI Technology Inc.                                                Page 27 of 92 
                               AVR7300 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 318.EMI 
1-1. Tuner FM 98.0 MHz 
7 CH Stereo Mode (
L1
)
 
 
 
 
 
 
 
 
 
 
Ground
 
 
Page of 93