Harman Kardon AVR 5550 (serv.man11) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 40 -
Order
No.
200245265
7.1
Standby mode:
U
=
207,0
V, I
=
0,029
A, P
=
5,7
W
Pout =
W
U
=
230,0
V, I
=
0,032
A, P
=
6,9
W
Pout =
W
U
=
254,4
V, I
=
0,041
A, P
=
8,7
W
Pout =
W
Measured at maximum non-clipped output:
U
=
207,0
V, I
=
5,29
A, P
=
912
W
Pout =
2 x 80,6
W
(F)
1 x 79,4
W
(C)
2 x 80,0
W
(S)
2 x 80,0
W
(S/W)
U
=
230,0
V, I
=
5,56
A, P
=
1060
W
Pout =
2 x 80,6
W
(F)
1 x 79,4
W
(C)
2 x 80,0
W
(S)
2 x 80,0
W
(S/W)
U
=
254,4
V, I
=
5,60
A, P
=
1170
W
Pout =
2 x 80,6
W
(F)
1 x 79,4
W
(C)
2 x 80,0
W
(S)
2 x 80,0
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Measured at 1/8 of maximum non-clipped output:
U
=
207,0
V, I
=
2,48
A, P
=
393
W
Pout =
2 x 10,1
W
(F)
1 x 9,90
W
(C)
2 x 10,0
W
(S)
2 x 10,0
W
(S/W)
U
=
230,0
V, I
=
2,54
A, P
=
444
W
Pout =
2 x 10,1
W
(F)
1 x 9,90
W
(C)
2 x 10,0
W
(S)
2 x 10,0
W
(S/W)
U
=
254,4
V, I
=
2,57
A, P
=
493
W
Pout =
2 x 10,1
W
(F)
1 x 9,90
W
(C)
2 x 10,0
W
(S)
2 x 10,0
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 40 -
Order
No.
200245265
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
2,57
A, P
=
493
W
Pout =
2 x 10,1
W
(F)
1 x 9,90
W
(C)
2 x 10,0
W
(S)
2 x 10,0
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Marking of loudspeaker terminals
“
SPEAKERS (8
Ω)
:
SR, SL, FR, FL”
”SPEAKERS (8
Ω)
:
CTR, SBR/MILTI R, SBL/MILTI L”
U =
254,4
V
4 Ohm
8 Ohm
16 Ohm
Ohm
Left
right
left
right
left
right
left
right
Measured max. output voltage in Vp
F)
35,9
C) 35,6
S) 35,8
S/W) 35,8
S) 35,8
S/W) 35,8
F) 35,9
C) -
S) 35,8
S/W) 35,8
C) -
S) 35,8
S/W) 35,8
Measured max. output power in W
F)
80,6
C) 79,4
S) 80,0
S/W) 80,5
S) 80,0
S/W) 80,5
F) 80,6
C) -
S) 80,0
S/W) 80,5
C) -
S) 80,0
S/W) 80,5
Measured max. mains power in W
1170
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 40 -
Order
No.
200245265
HEATING
∆
t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
P
t1 =
22,7 °C
22,7 °C
t2 =
24,3 °C
24,4 °C
Test voltage
207 V
254,4 V
Winding
R1/
Ω
R2/
Ω
∆
t measured
∆
t allowed *)
Insulation
class
class
Main transf. pr. winding (207V)
1,535
1,902
59,9
85
Class E
Main transf. pr. winding (254,4V)
1,535
1,950
67,8
85
Class E
Sub transf. pr. winding (207V)
716
838
42,2
85
Class E
Sub transf. pr. winding (254,4V)
716
893
61,9
85
Class E
Other measured parts
∆
t measured
at 207V
∆
t measured
at 254,4V
∆
t allowed *)
Main transformer core
38,9
43,6
85
Sub transformer core
28,8
40,8
85
Diode, D201 body
63,3
64,2
-
PWB near D201
28,7
29,6
85
Diode, D501 body
47,7
48,7
-
PWB near D501
34,6
35,3
85
D501
heat-sink
51,4 51,7 -
Diode, D502 body
29,0
31,7
-
PWB near D502
24,0
24,2
85
Diode, D503 body
35,1
36,5
-
PWB near D503
22,3
25,9
85
Diode, D505 body
14,3
14,9
-
PWB near D505
18,3
19,2
85
E. Capacitor, C202 body
22,0
24,4
-
E. Capacitor, C504 body
28,3
30,6
-
Regulator, IC53 heat-sink
31,5
47,7
-
Power TR, Q435 body
58,4
66,9
-
Power TR, Q439 body
62,1
72,7
-
-
IEC 60065, 6th edition : 1998
-
- Page 10 of 40 -
Order
No.
200245265
HEATING (continued)
P
Other measured parts
∆
t measured
at 207V
∆
t measured
at 254,4V
∆
t allowed *)
Power TR, Q437 body
53,8
63,4
-
PWB near Q437
51,6
59,3
85
Fan 1, body (inner)
22,4
24,0
60
Fan 2, body (outer)
37,0
41,6
60
Main
heat-sink
42,6 47,3 -
Appliance inlet body
12,1
13,2
60
Top enclosure above main heat-sink
17,1
18,1
40
Top enclosure above main transformer
3,2
3,6
40
Switch
button
0,9 2,4 50
Comments
No other parts were observed to create any hazard due to temperature rise.
P
*) Temperature rise limits for Singapore is 10K less.
P
7.2
Softening temperature of insulating
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
°
C
No temperature measured during heating test and fault
cond. tests requires this test (7.2) to be performed.
cond. tests requires this test (7.2) to be performed.
N
Tested parts
Temperature
under normal
operating con-
ditions (°C)
Temperature
under fault
conditions
(°C)
Softening
temperature
(°C)
Click on the first or last page to see other AVR 5550 (serv.man11) service manuals if exist.