IEC 60065, 6th edition : 1998
 - 
- Page 39 of 40 - 
 
 
   
 Order 
No. 
200245265
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. No  Fault 
Test V 
Position 
Test 
time 
Fuse No
Primary 
current 
Mains power/temperatures/results 
D101 
S-c 
254,4 
A - C 
1 hr   
50 min 
2,60 A 
FL display off immediately. 
Input current stabilised at 2,60A. 
Sub transformer primary winding 
heated up to 67K and stabilised. 
No hazard.   
C102 
S-c 
254,4 
20 min 
2,60 A 
FL display off immediately. 
Input current stabilised at 2,60A. 
R114 opened. 
No hazard. 
C102 
S-c 
207 
3 hr 
2,50 A 
FL display off immediately. 
Input current stabilised at 2,60A. 
Sub transformer primary winding 
heated up to 119K and stabilised. 
R114 damaged. 
Dielectric strength test OK. 
No hazard. 
Speaker 
Terminal 
S-c 254,4 
Front 
(R-ch.) 
10 min 
F101 
Protection circuit operated 
immediately (Relay, SK11 off). 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard.   
Top cover 
opening 
Blocked 
254,4 
3 hr 
F101 
2,57 A 
Normal operating. 
Components are heated up to: 
- Main transf. pr. winding  : 69K 
- Main transf. core   
: 46K 
- Sub transf. pr. winding  : 65K 
- Sub transf. core   
: 45K 
- D201 body   
 
: 67K 
- PWB near D201 
: 37K 
- Q437 body   
 
: 71K 
and stabilised. 
Dielectric strength test OK.   
No hazard.   
Fan 2 
(outer) 
Locked 254,4  - 
hr 
20 min 
F101 
2,57 A 
Components are heated up to: 
- Main transf. pr. winding  : 50K 
- Main transf. core   
: 32K 
- Sub transf. pr. winding  : 62K 
- Sub transf. core   
: 39K 
- D201 body   
 
: 56K 
- PWB near D201 
: 28K 
- Q437 body   
 
: 65K 
and protection circuit operated after 
1 hr 20 min. 
(Relay, SK11 off).
 
Dielectric strength test OK.   
No hazard.   
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 40 of 40 - 
 
 
   
 Order 
No. 
200245265
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. No  Fault 
Test V 
Position 
Test 
time 
Fuse No
Primary 
current 
Mains power/temperatures/results 
Pmax 
operat. 
Maximu
m non -
clipped 
output 
signal 
254,4 
25 min 
F101 
5,60 A 
Components are heated up to: 
- Main transf. pr. winding  : 120K 
- Main transf. core   
: 40K 
- Sub transf. pr. winding    : 53K 
- Sub transf. core   
: 32K 
- D201 body   
: 116K 
- PWB near D201 
: 47K 
- Q437 body   
: 64K 
- PWB near Q437 
: 62K 
and main transformer’s thermal 
fuse opened after 25 min. 
Dielectric strength test OK.   
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998    -
 
- Page 1 of 3 - 
 
 
   
 Order 
No. 
200245265
 
 
 
APPENDIX   
CENELEC EN 60065:1998 
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL 
DEVIATIONS AND OTHER INFORMATION     
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
 DE 
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden. 
P = Pass, F = Fail, = Not applicable.   
1.1.1 C 
Replace text in Note 1 by : This 
standard can be used as a guide for 
the testing of battery operated 
apparatus.  
 
2.6.1 S 
(DK)    Class I apparatus provided with 
a plug not establishing earthing 
continuity when inserted in Danish 
socket-outlets, see 15.1.1. 
 
Class II apparatus 
3.1 C 
Delete the note. Add the following 
indent : exposure to excessive sound 
pressures from headphones or 
earphones.  
 
 
D 
(DE) Marking in case of intrinsically 
ionizing radiation, cathode-ray tubes 
 
D 
(IT) Marking and instruction 
requirements  
- power consumption (W) for TV 
receivers  
 
6.1 D 
(DE) Limits for ionizing radiation, TV 
receivers (max. 1
µ
Sv/h) 
 
15.1.1 C 
Delete notes 1 and 2. 
Add to note 4: Attention is drawn to 
the fact that a standard is under 
preparation (presently prEN 50074) 
for socket-outlets which allow 
connection of Class II appliances only. 
 
15.1.1 S 
(DK) Mains plug according to Heavy 
Current Regulations, Section 107-2-
D1 
(DK) Mains socket outlets Cl.I 
(DK) Mains socket outlets Cl.II 
The power cord is not provided with the equipment. 
Ref. Summary of Testing. 
15.1.1 S 
(IE) Mains plug, flexible cord, 
according to statutory Instrument 525: 
1997 
The power cord is not provided with the equipment.   
Ref. Summary of Testing. 
15.1.1 S 
(NO) Mains socket outlets CI.II 
 
15.1.1 S 
(GB) Mains plug, flexible cord, 
according to statutory Instrument 
1768: 1994 
The power cord is not provided with the equipment.   
Ref. Summary of Testing. 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998    -
 
- Page 2 of 3 - 
 
 
   
 Order 
No. 
200245265
 
 
 
 
15.2 C 
Delete note 2
 
 
 
16.1 C 
Delete note 1
 
 
 
16.2 C 
Delete the note 
 
 
 
20 C 
Delete note 2
 
 
 
 
APPENDIX 
ANNEX B (normative) 
 
 
Annex B C 
Delete note 2 
 
 
B.5.4.1  S 
(NO) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
 
Applicable text is: 
"Apparatet må kun tilkoples jordet 
stikkontakt" or   
"Jordet stikkontakt skal benyttes når 
apparatet tilkoples datanett" 
Swedish text can also be accepted. 
 
B.5.4.1  S 
(SE) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag när den ansluts till ett nätverk"   
 
B.5.4.1 e) C 
Delete notes 1 and 2 
 
 
B.8.1 C 
Delete notes 1, 2 and 3 
 
 
B.8.1 S 
(DK) Method b) is permitted only for 
PERMANENTLY CONNECTED 
APPARATUS 
 
B.8.1 S 
(NO) Method b) is not permitted 
 
B.8.2 C 
Delete the note 
 
 
B.14.12 C 
Delete notes 1 and 2 
 
 
B.14.12 S 
(DK) The following note is added: 
NOTE in Denmark the use of surge 
suppressors between the 
TELECOMMUNICATION NETWORK 
and conductive ACCESSIBLE parts or 
TERMINALS which are considered to 
be ACCESSIBLE, is allowed only for 
PERMANENTLY CONNECTED 
APPARATUS. 
 
Page of 51
Display

Click on the first or last page to see other AVR 5550 (serv.man11) service manuals if exist.