Harman Kardon AVR 505 (serv.man13) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 37 -
Order
No.
11151
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
Q661
S-c
254,4
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down after 6 min.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C566 S-c
254,4 -
20
min
F907
F905
F906
F905
F906
1,05 A
Surround L channel signal output
off immediately.
Input current stabilised at 1,04A.
No component damaged.
No hazard.
off immediately.
Input current stabilised at 1,04A.
No component damaged.
No hazard.
D962
S-c
254,4
A - C
15 min
-
1,27 A
Sub transformer primary winding
heated-up to 116K thermal fuse
opened after 15 min.
Dielectric strength test O.K.
No hazard.
heated-up to 116K thermal fuse
opened after 15 min.
Dielectric strength test O.K.
No hazard.
C906
S-c
254,4
-
16 min
-
< 0,03 A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 120K thermal fuse
opened after 16 min.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 120K thermal fuse
opened after 16 min.
Dielectric strength test O.K.
No hazard.
C907
S-c
254,4
-
1 hr
-
< 0,02 A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 79K and stabilised.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 79K and stabilised.
Dielectric strength test O.K.
No hazard.
Speaker
Terminal
Terminal
S-c 254,4
Surround
(
(
L - ch.)
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Top cover
opening
opening
Blocked
254,4
-
10 min
F907
1,20 A
Unit shut down after 9 min.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Pmax
operating
Maximum
non-
clipped
output
signal
non-
clipped
output
signal
254,4 -
33
min F907,
F903,
F904,
F905,
F906
F904,
F905,
F906
2,62 A
The components are heated up to:
- Main transf. pr. winding : 136K
- Main transformer core
- Main transf. pr. winding : 136K
- Main transformer core
: 91K
- D992 body
: 69K
- PWB near D991
: 83K
- PWB near Q661
: 50K
and main transformer’s thermal fuse
opened after 33 min.
Dielectric strength test OK.
No hazard.
opened after 33 min.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 1 of 3 -
Order
No.
11151
APPENDIX
CENELEC EN 60065:1998
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL
DEVIATIONS AND OTHER INFORMATION
DEVIATIONS AND OTHER INFORMATION
P
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
DE
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden.
P = Pass, F = Fail, N = Not applicable.
P = Pass, F = Fail, N = Not applicable.
1.1.1 C
Replace text in Note 1 by : This
standard can be used as a guide for
the testing of battery operated
apparatus.
standard can be used as a guide for
the testing of battery operated
apparatus.
N
2.6.1 S
(DK) Class I apparatus provided
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
Class II apparatus
N
3.1 C
Delete the note. Add the following
indent : exposure to excessive
sound pressures from headphones
or earphones.
indent : exposure to excessive
sound pressures from headphones
or earphones.
5 D
(DE) Marking in case of intrinsically
ionizing radiation, cathode-ray tubes
ionizing radiation, cathode-ray tubes
N
5 D
(IT) Marking and instruction
requirements
- power consumption (W) for TV
receivers
requirements
- power consumption (W) for TV
receivers
N
6.1 D
(DE) Limits for ionizing radiation, TV
receivers (max. 1
receivers (max. 1
µ
Sv/h)
N
15.1.1 C
Delete notes 1 and 2.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
15.1.1 S
(DK) Mains plug according to Heavy
Current Regulations, Section 107-2-
D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
Current Regulations, Section 107-2-
D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
P
15.1.1 S
(IE) Mains plug, flexible cord,
according to statutory Instrument
525: 1997
according to statutory Instrument
525: 1997
P
15.1.1 S
(NO) Mains socket outlets CI.II
P
15.1.1 S
(GB) Mains plug, flexible cord,
according to statutory Instrument
1768: 1994
according to statutory Instrument
1768: 1994
P
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 2 of 3 -
Order
No.
11151
15.2 C
Delete note 2
16.1 C
Delete note 1
16.2 C
Delete the note
20 C
Delete note 2
APPENDIX
ANNEX B (normative)
No TNV circuit
N
Annex B C
Delete note 2
B.5.4.1 S
(NO) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
B.5.4.1 S
(SE) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
B.5.4.1 e) C
Delete notes 1 and 2
B.8.1 C
Delete notes 1, 2 and 3
B.8.1 S
(DK) Method b) is permitted only for
PERMANENTLY CONNECTED
APPARATUS
PERMANENTLY CONNECTED
APPARATUS
B.8.1 S
(NO) Method b) is not permitted
B.8.2 C
Delete the note
B.14.12 C
Delete notes 1 and 2
B.14.12 S
(DK) The following note is added:
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or TERMINALS
which are considered to be
ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or TERMINALS
which are considered to be
ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 3 of 3 -
Order
No.
11151
B.14.12 S
(NO) The following note is added:
NOTE in Norway, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
NOTE in Norway, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
B.14.12 S
(SE) The following note is added:
NOTE in Sweden, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag."
NOTE in Sweden, for Class I apparatus
intended to be connected to the MAINS
by means of a plug, surge suppressors
may only be connected between TNV
circuits and ACCESSIBLE parts if the
apparatus has a marking stating that it
must be connected to an earthed
MAINS socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag."
APPENDIX
ANNEX G (normative)
Annex G C
Delete the note
APPENDIX
ANNEX P (informative)
Annex P C
Add the following notes for the
standards indicated :
standards indicated :
IEC 60130 :
NOTE: IEC 60130-9:1989 + A1:1993
are harmonized as EN 60130-9 (not
modified).
IEC 60169 :
NOTE: Parts 23, 24 and 25 are
harmonized as Ens (not modified).
IEC 60173 :
NOTE: Harmonized as HD 27 S1:1983
(not modified).
IEC 60260 :
NOTE: Harmonized as HD 98 S1:1977
(not modified).
IEC 60335-2-56 :
NOTE: Harmonized as EN 60335-2-56:
1997 (not modified).
IEC 61040 :
NOTE: Harmonized as EN 61040: 1992
(not modified).
IEC 60695 :
NOTE: Harmonized as EN 60695
series (not modified).
NOTE: IEC 60130-9:1989 + A1:1993
are harmonized as EN 60130-9 (not
modified).
IEC 60169 :
NOTE: Parts 23, 24 and 25 are
harmonized as Ens (not modified).
IEC 60173 :
NOTE: Harmonized as HD 27 S1:1983
(not modified).
IEC 60260 :
NOTE: Harmonized as HD 98 S1:1977
(not modified).
IEC 60335-2-56 :
NOTE: Harmonized as EN 60335-2-56:
1997 (not modified).
IEC 61040 :
NOTE: Harmonized as EN 61040: 1992
(not modified).
IEC 60695 :
NOTE: Harmonized as EN 60695
series (not modified).