DOWNLOAD Harman Kardon AVR 460 (serv.man3) Service Manual ↓ Size: 435.96 KB | Pages: 17 in PDF or view online for FREE

Model
AVR 460 (serv.man3)
Pages
17
Size
435.96 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-460-sm3.pdf
Date

Harman Kardon AVR 460 (serv.man3) EMC - CB Certificate ▷ View online

Ref. No.:
 
LR500120906P
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 5 of 17 
 
 
3. 
Test Summary
 
 
3.1 Summary of tests 
Parameter 
Applied Standard 
Status
I.  Emission
 
Disturbance Voltage at the mains terminals 
EN55013:2001+A1:2003+A2:2006 
NA 
Disturbance Voltage of ANT. terminal 
EN55013:2001+A1:2003+A2:2006 
NA 
Wanted Signal & Disturbance Voltage at RF Output Terminal 
EN55013:2001+A1:2003+A2:2006 
NA 
Disturbance power   
EN55013:2001+A1:2003+A2:2006 
NA 
Radiated disturbances 
EN55013:2001+A1:2003+A2:2006 
NA 
Harmonic Current emission 
EN61000-3-2:2006 
NA 
Voltage fluctuations and flicker   
EN61000-3-3:1995+A1:2001+A2:2005 
NA 
II. Immunity 
RF Voltages(in differential mode):S1 
EN55020:2007 
NA 
RF Voltages (in common mode):S2b 
EN55020:2007 
NA 
RF Voltages( input interference):S2a 
EN55020:2007 
NA 
Ambient Electromagnetic Fields:S3 
EN55020:2007 
NA 
Screening Effectiveness: S4 
EN55020:2007 
NA 
Electrostatic discharge 
EN 61000-4-2:1995+A1:1998+A2:2001 
RF e.m. Field Keyed carrier(900MHz) 
EN 61000-4-3:2006+A1:2008 
Electrical fast transients 
EN 61000-4-4:2004 
 
 
 
Note 1: C=Complies   NC=Not Complies   NT=Not Tested   NA=Not Applicable 
Note 2: The data in this test report are traceable to the national or international standards. 
 
 
Ref. No.:
 
LR500120906P
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 6 of 17 
 
 
3.2 IMMUNITY 
   
3.2.1 Electrostatic Discharge   
Definition: 
    The test assesses the ability of the EUT to operate as intended in the event of an electrostatic discharge. 
We were performed the test according to LTA procedure QP-014. 
 
Test method 
:  EN 61000-4-2 
Discharge Impedance 
:  330
Ω ±10% / 150pF ±10% 
Type of Discharge (air discharge) 
:  
± 2kV, ± 4kV, ± 8KV 
Type of Discharge (contact discharge) 
:  
± 2kV, ± 4KV 
Number of discharges at each point 
:    10 of each polarity 
Discharge Repetition on Rate 
:    1 / sec 
Test mode 
:  PLAY mode 
Performance Criteria 
:    B (Refer to the appendix 1) 
Result 
 Complies
 
 
Measurement Data: 
- Uncertainty(ESD)    = +/- 5% (with a 95% confidence level, k=2) 
“It has been demonstrated that the ESD generator meets the specified requirements in the standard with at least 95% 
confidence.”  
- refer to the Next page 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TEST EQUIPMENT USED:    12, 45
 
Ref. No.:
 
LR500120906P
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 7 of 17 
 
1. Indirect Discharge 
No. 
Position 
Kind of Discharge 
Results 
Remarks 
 
HCP Contact 
Complies 
No 
reaction 
recognized 
 
VCP Contact 
Complies 
No 
reaction 
recognized 
2. Direct Discharge 
No. 
Position 
Kind of 
Discharge 
Results 
Remarks 
1 ENCLOSURE  Contact 
Complies  No 
reaction 
recognized 
SCREW 
Contact Complies 
No 
reaction 
recognized 
3 PHONES  Contact 
Complies No reaction recognized 
4 USB 
Air 
Complies 
No 
reaction 
recognized 
5 VIDEO  Contact 
Complies No reaction recognized 
AUDOI (R/L) 
Contact 
Complies 
No reaction recognized 
7 RADIO 
ANTENNAS  Contact Complies No 
reaction 
recognized 
RADIO (AM / GND) 
Air 
Complies 
No reaction recognized 
9 COMPONENT 
VIDEO  Contact  Complies No 
reaction 
recognized 
10 
2 ONE 2 REMOTE 
Contact 
Complies 
No reaction recognized 
11 HDMI  Contact 
Complies No 
reaction 
recognized 
12 
THE BRIDGE III 
Contact 
Complies No 
reaction 
recognized 
13 COMPONENT 
OUT  Contact Complies No 
reaction 
recognized 
14 ANALOG 
AUDIO  Contact Complies 
No 
reaction 
recognized 
15 
6/8 CHANNEL INPUT 
Contact 
Complies 
No reaction recognized 
16 DIGITAL 
AUDIO  Contact Complies No 
reaction 
recognized 
17 PRE-OUT  Contact 
Complies  No reaction recognized 
18 SPEAKERS 
(8.2) 
Air  Complies No 
reaction 
recognized 
19 
AC OUTLET 
Air 
Complies 
No reaction recognized 
20 
ON/OFF SWITCH 
Air 
Complies 
No reaction recognized 
21 
FRONT BUTTON 
Air 
Complies 
No reaction recognized 
22 
DIGITAL AUDIO 
(OPTICAL) 
Air Complies 
No 
reaction 
recognized 
 
 
 
 
 
 
 
 
TEST EQUIPMENT USED:    12, 45
 
Ref. No.:
 
LR500120906P
 
 Copyright 
c
 2009, LTA
 CO., LTD
 
Page 8 of 17 
 
 
3.2.2 RF e.m. field keyed carrier 
     
Definition: 
    The test assesses the ability of the EUT to operate as intended in the presence of a radio frequency electromagnetic 
field disturbance. 
We were performed the test according to LTA procedure QP-014. 
 
Test method 
:  EN 61000-4-3 
Frequency range 
:    900㎒  ±5㎒ 
Test level 
:    3 V/m (measured unmodulated) 
Duty cycle 
:    1/8 
Rep. frequency 
:    217Hz 
Test mode 
:  PLAY mode 
Performance Criteria 
:    A (Refer to the appendix 1) 
Result 
:  
Complies
 
 
Measurement Data:   
- Uncertainty = +/- 1.6dB (with a 95% confidence level, k=2.28) 
“It has been demonstrated that the RS generator meets the specified requirements in the standard with at least 95% 
confidence.” 
 
Result 
Port 
Test mode 
Horizontal 
Vertical 
Remark 
Enclosure PLAY 
mode Complies 
Complies 
No reaction recognized 
 
 
 
 
 
 
 
 
 
 
 
 
 
TEST EQUIPMENT USED:    22, 30, 31, 32, 33, 34, 35
 
 
Page of 17
Display