Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 5 of 39 -
Order
No.
200245266
Standardized approval marks
1
SCOPE
According to the standard
2
DEFINITIONS
According to the standard
3
GENERAL REQUIREMENTS
According to the standard
Safety class of the apparatus
Class II
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to the standard
4.1.4 -
4.2.12.
4.2.12.
Normal operating
conditions/position/adjustments
conditions/position/adjustments
With all users controls set to obtain maximum power from
the mains and at 1/8 of max. audio output power.
Positioned according to users manual
the mains and at 1/8 of max. audio output power.
Positioned according to users manual
5
MARKING AND INSTRUCTIONS
P
Copy of the markings :
SEE ATTACHED PHOTOS
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
P
Rated supply voltage and symbol
AC-symbol (
~
)
230V
P
Rated mains frequency
50Hz
P
Rated current or power consumption
930W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet
”AC OUTLETS, 230V~50Hz”
”SWITCHED, 50W MAX”
”UNSWITCHED, 100W MAX”
”AC OUTLETS, 230V~50Hz”
”SWITCHED, 50W MAX”
”UNSWITCHED, 100W MAX”
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Adequate instructions supplied.
P
-
IEC 60065, 6th edition : 1998
-
- Page 6 of 39 -
Order
No.
200245266
Hazardous live terminals,
instructions for wiring
instructions for wiring
No live terminal.
N
Instructions for replacing lithium
battery
battery
No lithium battery
N
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No explanation required (indication in the form of
illumination)
illumination)
N
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF from
the mains, info required
connected equipment
If not completely switched OFF from
the mains, info required
The apparatus is not for permanent connection
N
6 HAZARDOUS
RADIATION
No radiation
N
6.1
High voltage (kV).
N
Focus voltage (kV)
N
Amount of radiation
N
6.2
Non-ionizing radiation (laser
radiation)
radiation)
N
6.2.1
Opening of any cover by hand
N
Mechanical interlocking device
N
Accessible emission normal
operation / classification
operation / classification
N
Labelling
N
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
N
Warning label requirement
N
7
HEATING UNDER NORMAL
OPERATING CONDITIONS
OPERATING CONDITIONS
P
Power consumption in the
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
In OFF/Stand-by position, the power consumption is less
than 15W.
than 15W.
P
Surge current needed in clause 14.6
when testing mains switches or
functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
when testing mains switches or
functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
Ref. clause 14.6.
P
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 39 -
Order
No.
200245266
7.1
Standby mode:
U
=
207,0
V, I
=
0,029
A, P
=
5,7
W
Pout =
W
U
=
230,0
V, I
=
0,032
A, P
=
6,9
W
Pout =
W
U
=
254,4
V, I
=
0,042
A, P
=
8,7
W
Pout =
W
Measured at maximum non-clipped output:
U
=
207,0
V, I
=
4,53
A, P
=
800
W
Pout =
2 x 67,6
W
(F)
1 x 66,8
W
(C)
2 x 66,4
W
(S)
2 x 66,1
W
(S/W)
U
=
230,0
V, I
=
4,75
A, P
=
931
W
Pout =
2 x 67,6
W
(F)
1 x 66,8
W
(C)
2 x 66,4
W
(S)
2 x 66,1
W
(S/W)
U
=
254,4
V, I
=
4,80
A, P
=
1027
W
Pout =
2 x 67,6
W
(F)
1 x 66,8
W
(C)
2 x 66,4
W
(S)
2 x 66,1
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Measured at 1/8 of maximum non-clipped output:
U
=
207,0
V, I
=
2,16
A, P
=
349
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
U
=
230,0
V, I
=
2,21
A, P
=
392
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
U
=
254,4
V, I
=
2,25
A, P
=
439
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 39 -
Order
No.
200245266
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
2,25
A, P
=
439
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Marking of loudspeaker terminals
“
SPEAKERS (8
Ω)
:
SR, SL, FR, FL”
”SPEAKERS (8
Ω)
:
CTR, SBR/MILTI R, SBL/MILTI L”
U =
254,4
V
4 Ohm
8 Ohm
16 Ohm
Ohm
Left
right
left
right
left
right
left
right
Measured max. output voltage in Vp
F)
32,9
C) 32,7
S) 32,6
S/W) 32,5
S) 32,6
S/W) 32,5
F) 32,9
C) -
S) 32,6
S/W) 32,5
C) -
S) 32,6
S/W) 32,5
Measured max. output power in W
F)
67,6
C) 66,8
S) 66,4
S/W) 66,1
S) 66,4
S/W) 66,1
F) 67,6
C) -
S) 66,4
S/W) 66,1
C) -
S) 66,4
S/W) 66,1
Measured max. mains power in W
1027
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P