Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 2 of 39 -
Order
No.
200245266
Additional test according to:
Common Modifications, Special National Conditions and
National Deviations
National Deviations
CENELEC EN 60065:1998. Common Modifications,
Special National Conditions and National Deviations.
(See Appendix CENELEC EN 60065:1998)
Special National Conditions and National Deviations.
(See Appendix CENELEC EN 60065:1998)
Other requirements
General remarks:
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to a table appended to the report.
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
Possible test case verdicts:
P = Pass, F = Fail, N = Not applicable. Placed in the column to the right (Verdict)
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to a table appended to the report.
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
Possible test case verdicts:
P = Pass, F = Fail, N = Not applicable. Placed in the column to the right (Verdict)
ADDITIONAL INFORMATION
DESCRIPTION OF EQUIPMENT UNDER TEST:
A/V Surround Receiver, Front/Center/Surround/Sub Woofer amplifier circuits, Tuner circuit, RCA
terminals, Antenna terminal, Optical terminals, S-video terminals, Mini jacks, A-BUS terminal, RS-
232 terminal and speaker terminals provided (see also photos).
terminals, Antenna terminal, Optical terminals, S-video terminals, Mini jacks, A-BUS terminal, RS-
232 terminal and speaker terminals provided (see also photos).
Manually operated mechanical switch (MOMS) provided in primary side. Standby/On mode
controlled by remote controller and/or manual operating
controlled by remote controller and/or manual operating
NAME AND ADDRESS OF OTHER PRODUCTION-SITES (FACTORIES):
No other production sites
INFORMATION ABOUT OTHER STANDARDS / DOCUMENTS CONSIDERED:
No other standards
TESTED ACCORDING TO NATIONAL REQUIREMENTS FOR THE FOLLOWING COUNTRIES:
CENELEC Countries and Singapore* :
*) Singapore Deviations for 6
*) Singapore Deviations for 6
th
edition are not announced yet, but additional testing for tropical
climate is performed.
LIST OF APPENDIXES / ENCLOSURES TO THE TEST REPORT:
CENELEC EN 60065:1998
Photos
-
IEC 60065, 6th edition : 1998
-
- Page 3 of 39 -
Order
No.
200245266
SUMMARY OF TESTING:
The apparatus complies with the requirements in IEC 60065:1998 and EN 60065:1998
Clause Information/Remarks
Comments
7.1
Heating
Additional testing for tropical climate is performed for
Singapore
Singapore
10.2
Humidity treatment
Additional testing for tropical climate is performed for
Singapore
Singapore
14.5.2
Fuse-links
F501, F502, F503, F504, F505 and F506 are US
approved type fuses that differ dimension with
IEC60127, and positioned in secondary side of the
apparatus.
The mentioned above fuses shall be replaced by
only with same rating and type of fuses as original
fuses, when replacing it.
approved type fuses that differ dimension with
IEC60127, and positioned in secondary side of the
apparatus.
The mentioned above fuses shall be replaced by
only with same rating and type of fuses as original
fuses, when replacing it.
15 and 16
Plug / External flexible cord
The equipment shall be provided with an approved
mains plug and cord complying with the national
regulations of the countries in which the appliance is
to be sold.
mains plug and cord complying with the national
regulations of the countries in which the appliance is
to be sold.
-
IEC 60065, 6th edition : 1998
-
- Page 4 of 39 -
Order
No.
200245266
TEST REPORT INFORMATION
It should be taken into account that this test report does not replace the text in the test specification.
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the
actual specification mentioned.
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the
actual specification mentioned.
IEC 60065, 6th edition:1998
The meaning of certain marks and abbreviations (Voltages and currents are r.m.s. values unless otherwise specified)
OK = no remarks
pr
= primary
? = unclear, borderline case
sec
= secondary
∆
t = temperature rise
pr-sec
= primary-secondary
tpr = thermal paper
pr-ss
= primary-static screen
h, m, s = hour, minute, second
pr-ic
= primary-iron core
U, I, P = voltage, current, power
pr-tra
= primary-transformer encl.
û,î = peak value
F
= fuse
n
= rated
PWB
= printed wiring board
= issue considered
LSL
= loudspeaker load
-
IEC 60065, 6th edition : 1998
-
- Page 5 of 39 -
Order
No.
200245266
Standardized approval marks
1
SCOPE
According to the standard
2
DEFINITIONS
According to the standard
3
GENERAL REQUIREMENTS
According to the standard
Safety class of the apparatus
Class II
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to the standard
4.1.4 -
4.2.12.
4.2.12.
Normal operating
conditions/position/adjustments
conditions/position/adjustments
With all users controls set to obtain maximum power from
the mains and at 1/8 of max. audio output power.
Positioned according to users manual
the mains and at 1/8 of max. audio output power.
Positioned according to users manual
5
MARKING AND INSTRUCTIONS
P
Copy of the markings :
SEE ATTACHED PHOTOS
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
P
Rated supply voltage and symbol
AC-symbol (
~
)
230V
P
Rated mains frequency
50Hz
P
Rated current or power consumption
930W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet
”AC OUTLETS, 230V~50Hz”
”SWITCHED, 50W MAX”
”UNSWITCHED, 100W MAX”
”AC OUTLETS, 230V~50Hz”
”SWITCHED, 50W MAX”
”UNSWITCHED, 100W MAX”
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
5.4
Instructions for use
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Adequate instructions supplied.
P