Harman Kardon AVR 360 (serv.man3) EMC - CB Certificate ▷ View online
Reference No. : 54120906G Page 28/56
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
18.May 09 14:05
RBW
9 kHz
MT
100 ms
PREAMP OFF
Att 10 dB
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
A4_AV
A4_QP
AVR360/230_Nonground line2(1KHz sine wave input at Analog 2)
Date: 18.MAY.2009 14:05:27
Reference No. : 54120906G Page 29/56
◀ Anam EMC Test Laboratory ▶
Annex B: Disturbance power
ANAM EMC Testing Lab.
30 MHz
300 MHz
1 PK
CLRWR
2 AV
CLRWR
SGL
TDS
6DB
dBµV
dBµV
21.May 09 17:15
RBW
120 kHz
MT
10 ms
PREAMP OFF
Att 10 dB AUTO
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
32.98 dBµV
159.760000000 MHz
A7_AV
A7_QP
AVR360/230_PHONES
Date: 21.MAY.2009 17:15:51
Reference No. : 54120906G Page 30/56
◀ Anam EMC Test Laboratory ▶
ANAM EMC Testing Lab.
30 MHz
300 MHz
1 PK
CLRWR
2 AV
CLRWR
SGL
TDS
6DB
dBµV
dBµV
21.May 09 17:17
RBW
120 kHz
MT
10 ms
PREAMP OFF
Att 10 dB AUTO
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
32.78 dBµV
135.160000000 MHz
A7_AV
A7_QP
AVR360/230_USB
Date: 21.MAY.2009 17:18:00
Reference No. : 54120906G Page 31/56
◀ Anam EMC Test Laboratory ▶
ANAM EMC Testing Lab.
30 MHz
300 MHz
1 PK
CLRWR
2 AV
CLRWR
SGL
TDS
6DB
dBµV
dBµV
RBW
120 kHz
MT
10 ms
PREAMP OFF
Att 10 dB AUTO
21.May 09 17:23
80 MHz
120 MHz
160 MHz
200 MHz
240 MHz
280 MHz
0
10
20
30
40
50
60
70
80
1
Marker 1 [T1 ]
28.36 dBµV
135.160000000 MHz
A7_AV
A7_QP
AVR360/230_FRONT COAXIAL
Date: 21.MAY.2009 17:23:19
Click on the first or last page to see other AVR 360 (serv.man3) service manuals if exist.