Harman Kardon AVR 355 (serv.man5) EMC - CB Certificate ▷ View online
- Page 4 of 9 -
www.nemko.com
Report No.
108568
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
P
No hazard from softening solder
No softening of solder
P
Flames extinguish within 10 seconds
No flames
P
Soldered terminations not used as protective
mechanism
mechanism
No protective mechanism
P
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No exceeding the limits of
Table 3.
Table 3.
P
a) Temperature rise of printed circuit boards
(PCB) to 20.1.3, exceeding the limits of table 3 by
not more than 100 K for an area not greater than
2 cm²
(PCB) to 20.1.3, exceeding the limits of table 3 by
not more than 100 K for an area not greater than
2 cm²
N/A
b) Temperature rise of printed circuit boards
(PCB) to 20.1.3 up to 300 K for an area not greater
than 2 cm² for a maximum of 5 min
(PCB) to 20.1.3 up to 300 K for an area not greater
than 2 cm² for a maximum of 5 min
N/A
14 COMPONENTS
14.5 Protective
devices
P
Protective devices used within their ratings
Approved fuses and
thermal links.
thermal links.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across
the device when opened
requirement of clause 13 for the voltage across
the device when opened
Adequate external clearance
and creepage distance.
and creepage distance.
P
14.5.1.1
a) Thermal cut-outs separately approved
None.
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
- Page 5 of 9 -
www.nemko.com
Report No.
108568
14.5.1.2
a) Thermal links separately approved
Thermal links in main and
sub transformer are
separately approved
component. See list of
critical components.
sub transformer are
separately approved
component. See list of
critical components.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable by sildering
re-settable by sildering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved
components according to
IEC 60127.
See list of critical components
components according to
IEC 60127.
See list of critical components
P
14.5.2.2
Correct marking of fuse-links adjacent to holder :
The following marking
applied;
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T3.15A L 250V
applied;
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T3.15A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ......... :
No possible to connect
fuses in parallel.
fuses in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .. :
replacing fuse-links without the use of a tool .. :
No replacement of fuses
possible by hand.
possible by hand.
P
- Page 6 of 9 -
www.nemko.com
Report No.
108568
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
253V or 198V
—
Ambient temperature (
o
C) ................................... :
23 - 26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Limit dT (K)
*), D707 (AC to -), S-c;
Normal operated, Input current stabilised at 2.54A,
F111 opened, No hazard (Tested time: 30 min).
Normal operated, Input current stabilised at 2.54A,
F111 opened, No hazard (Tested time: 30 min).
N/A N/A
**), D707 (AC to -), S-c;
Normal operated, Input current stabilised at 2.31A.
F111 opened, No hazard (Tested time: 30 min).
Normal operated, Input current stabilised at 2.31A.
F111 opened, No hazard (Tested time: 30 min).
N/A N/A
*), D707 (AC to +), S-c;
Normal operated, Input current stabilised at 2.53A,
F110 opened, No hazard (Tested time: 10 min).
Normal operated, Input current stabilised at 2.53A,
F110 opened, No hazard (Tested time: 10 min).
N/A N/A
**), D707 (AC to +), S-c;
Normal operated, Input current stabilised at 2.32A,
F110 opened, No hazard (Tested time: 10 min).
Normal operated, Input current stabilised at 2.32A,
F110 opened, No hazard (Tested time: 10 min).
N/A N/A
*), C129, S-c;
Normal operated, Input current stabilised at 2,46A,
F110 and F111 opened, No hazard (Tested time: 20 min).
Normal operated, Input current stabilised at 2,46A,
F110 and F111 opened, No hazard (Tested time: 20 min).
N/A N/A
**), C129, S-c;
Normal operated, Input current stabilised at 2,26A,
F110 and F111 opened, No hazard (Tested time: 20 min).
Normal operated, Input current stabilised at 2,26A,
F110 and F111 opened, No hazard (Tested time: 20 min).
N/A N/A
*)
Tested
voltage
253V
**)
Tested
voltage
198V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
- Page 7 of 9 -
www.nemko.com
Report No.
108568
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
1
)
Main
transformer
Bobbin Mtl.
Thermal fuse
transformer
Bobbin Mtl.
Thermal fuse
Seoul Electronics
& Telecom Co.Ltd.
Wintech Plolymer
Therm-O-Disc.
& Telecom Co.Ltd.
Wintech Plolymer
Therm-O-Disc.
KLT5W033ZE
CLT5W033ZE
CN9030
E4A51167C
CLT5W033ZE
CN9030
E4A51167C
Class B
PET, V-0, 155°C
10A/250V, 167°C
PET, V-0, 155°C
10A/250V, 167°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL, E213445
VDE
UL, E213445
VDE
Sub
transformer
Bobbin Mtl.
Bobbin Cap. Mtl
Thermal fuse
transformer
Bobbin Mtl.
Bobbin Cap. Mtl
Thermal fuse
Seoul Electronics
& Telecom Co.Ltd.
LG Chemical Ltd.
LG Chemical Ltd.
Uchihashi Estec
& Telecom Co.Ltd.
LG Chemical Ltd.
LG Chemical Ltd.
Uchihashi Estec
KLT5J039ZE
CLT5J039ZE
GP2306F(#)
GP1006F(#)
44X
CLT5J039ZE
GP2306F(#)
GP1006F(#)
44X
Class E
PBT, V-0, 140°C
PBT, V-0, 130°C
0,5A/250V, 133°C
PBT, V-0, 140°C
PBT, V-0, 130°C
0,5A/250V, 133°C
IEC60065
clause 14.3
UL94
UL94
IEC60691
clause 14.3
UL94
UL94
IEC60691
1.)
UL, E67171
UL, E67171
VDE
UL, E67171
UL, E67171
VDE
Appliance inlet
Rich Bay Co., Ltd. R-301(21)
10A/250V
IEC60320
VDE
Socket-outlet
(OL91)
(OL91)
Dae Ryung Elect.
Dongbo Industri.
Dongbo Industri.
A3-02-D006
A302D006
A302D006
2.5A/250V ~
2.5A/250V ~
2.5A/250V ~
IEC60884-1
IEC60884-1
IEC60884-1
NEMKO
NEMKO
NEMKO
Mains switch
(BN90)
(BN90)
Jackson Elect.
JS-606
6A 250V
IEC60065
IEC61058-1
FIMKO
Mains relay
(RY94)
(RY94)
Tyco Electronics
SDT-S-112DMR
8A/120A 250V
IEC60065
IEC 61058-1
IEC 61058-1
SEMKO
Mains fuse
(F901)
alt.
alt.
(F901)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
06.3
5T
TSD
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Sec. Fuse *)
(F110, F111)
alt.
alt.
(F110, F111)
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
0663
MRT
SR-5
TR5 382
MRT
SR-5
TR5 382
T3.15A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Outlet fuse
(F902)
alt.
alt.
(F902)
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
0663
MRT
SR-5
TR5 382
MRT
SR-5
TR5 382
T2.5A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Relay across
the cap (C904)
alt.
alt.
alt.
the cap (C904)
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC60384-14,
2
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
*) Electrical rating changed fuses from T2.5A/250V to T3.15A/250V (bold)
1
) an asterisk indicates a mark which assures the agreed level of surveillance
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
Click on the first or last page to see other AVR 355 (serv.man5) service manuals if exist.