DOWNLOAD Harman Kardon AVR 35 (serv.man2) Service Manual ↓ Size: 14.6 MB | Pages: 80 in PDF or view online for FREE

Model
AVR 35 (serv.man2)
Pages
80
Size
14.6 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
avr-35-sm2.pdf
Date

Harman Kardon AVR 35 (serv.man2) Service Manual ▷ View online

TEST EQUIPMENT REQUIRED
1) AM/FM Signal generator
2) Digital Multimeter
3) Distortion lever meter
BUTTON
ST. POWER
T. MON
CD
DVD
VID 1
VID 2
VID 3
SLEEP
TUNING
TUNING
PRESET SCAN
PRESET
PRESET
TUN. MODE(RDS)
DIGITAL
PRO LOGIC
3 STEREO
HALL 1
HALL 2
THEATER
TEST TONE
SURR. OFF
SPEAKER
CHANNEL
DIG. SELECT
DELAY
MUTE
VOLUME UP
VOLUME DOWN
SET
AM/FM
SEGMENT(Large)
POWER
TAPE MONITOR
CD
DVD
VIDEO 1
VIDEO 2
VIDEO 3
SLEEP
TUNING DOWN
TUNING UP
PRESET SCAN
PRESET DOWN
PRESET UP
NO RDS
DOLBY AC-3
PRO LOGIC
3 STEREO
HALL 1
HALL 2
THEATER
TEST TONE
SURR OFF
FRNT SPEAKER
FRONT L LEV
COAXIAL
S DELAY TIME
MUTE
VOLUME UP
VOLUME DOWN
SET
COMM DOWN
COMM UP
TUNER
SEGMENT(Small)
TUNED, MONO, STEREO, AUTO, MEMORY, PRESET, 88
RDS, PTY, CT, RT
DIGTAL, AC-3, NIGHT
PRO LOGIC, PCM
3-STEREO
HALL 1
HALL 2
THEATER
MUTE
ANALOG, OPT, COAX
ALIGNMENT PROCEDURES
1. FM MONO. Distortion adjustment
step
1
2
Input Signal Source
Connection
Signal generator
output to FM
antenna
terminal.(750hm)
Signal
Frequency
98MHz
Source Signal Output Level and
Modulation
1000uV/m (60dBu)
MONO 1kHz/
Dev. 75kHz
Reception
Frequency
98MHz
(P5)
Adjustment
Point
T804
T805
Adjustment
Value
0mV 0.5mV
(R831)
Distortion
level
at
TAPE-OUT
Minimum
3. FM STEREO Separation Adjustment
step
1
2
Input Signal Source
Connection
Signal generator
output to FM
antenna
terminal.(750hm)
Signal
Frequency
98MHz
Source Signal Output Level and
Modulation
same specification as
distortion adjustment.
Input only L channel
FM STEREO
same specification as
distortion adjustment.
Input only R channel
FM STEREO
Reception
Frequency
98MHz
(P5)
98MHz
(P5)
Adjustment
Point
VR803
VR803
Adjustment
Value
Output level
at TAPE-OUT
channel R
Minimum
Output level
at TAPE-OUT
channel L
Minimum
2. FM MUTING LEVEL ADJUSTMENT
Turn variable resistor VR801 and stop at position "TUNED" is not shown (not indicated), then again turn the variable resistor VR801 to the
opposite revolution and stop at a position "TUNED" is shown.
step
1
2
Input Signal Source
Connection
Signal generator
output to FM
antenna
terminal.(750hm)
Signal
Frequency
98MHz
Source Signal Output Level and
Modulation
10uV/m (20dBu)
MONO 1kHz/
Dev. 75kHz
Reception
Frequency
98MHz
(P5)
AUTO
SCAN
Adjustment
Point
VR801
Only confirm
Adjustment
Value
"TUNED"
indicate on VFD
"TUNED"
indicate on VFD
- 9 -
1. All Clear
2. VFD segment illumination & text
This service program can clear all memorized operations and functions.
When the POWER ON, press the "AM/FM" button while pressing the "PRO LOGIC"button.
After this, Preset memory will be set to these frequencies.
This service procedure will illuminate all segments by the following steps
(1) Press the Power ON buttn(Push Knob) while you are holding the TEST TONE (dts) button.
(2) Then "TEST MODE" character will be shown on VFD Display.
(3) This set do not have Auto VFD segement check function. So For your checking the VFD
states according to each function, Please press any function button which you want to test.
(4) for example : Tape monitor & CD
1) Press the POWER ON button(push knob) while you are holding the TEST TONE (dts) button.
2) Then "TEST MODE" character will be shown on VFD Display.
3) Press the t.MON button on Front, then you are able to see " TAPE MONITOR" Character on VFD Display.
4) Press the CD button on FRont, then you are able to see "CD" Character on VFD Display.
FM
AM
VERSION
120
230,230RDS
VERSION
120
230,230RDS
P1
87.5
87.50
P9
520
522
P2
88.0
88.00
P10
600
594
P3
90.0
90.00
P11
610
999
P4
95.0
95.00
P12
1000
1395
P5
98.0
98.00
P13
1400
1611
P6
99.0
99.00
P14
1500
P7
106.0
106.00
P15
1710
P8
108.0
108.00
2
step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output Level and
Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
1395kHz
(230,230RDS)
1400kHz(120)
CT801
5. AM-Tracking Adustment (MW)
Signal Generator
output to transmission
loop antenna
( standard required loop)
:
5mV/m(74dBu)
400Hz
MOD.30%
594kHz
(230,230RDS)
600kHz(120)
594kHz
(230,230RDS)
600kHz(120)
T801
Output level(L or R)
at
TAPE-OUT
Minimum
Output level(L or R)
at
TAPE-OUT
Minimum
2
step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output Level and
Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
7. AM auto stop Adjustment
Signal Generator
output to transmission
loop antenna
(standard required loop)
1000uV/m(60dBu)
400Hz
MOD.30%
AUTO SCAN
"TUNED"
indicate on
VFD
999kHz
(230,230RDS)
1000kHz
(120)
999kHz
(230,230RDS)
1000kHz(120)
Only
Contirm
VR802
"TUNED"
indicate on
VFD
8. Main Amp ldling current Adjustment
4) CAUTION
(1) whenever power or driver transistors are changed, after repair you must re-adjust the idle current for repair, have to re-adjust that idle
current again.
(2) Discharge each large elec. Capacitor C481, and C482(8200u) on main amp board, and C691, C692(6800uF/50V) on surround amp board.
1) Alignment condition
(1) Adjust each of the variable resistors below in both the main and surround boards to the center position :
MAIN AMP BOARD : VR401, VR402, VR501
SURROUND AMP BOARD : VR601, VR602
2) Warming up system
After he above adjustment, turn the power ON and let the receiver warm up for 5 minutes to achieve a stable temperature for the driver and
power transistors.
3) Measurement condition
Adjust each variable resistor listed below clockwise for each channel, and adjust refer the following table for the details.
6. AM IF Adjustment
step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output Level and
Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
T803
Output level(L or R)
at
TAPE-OUT
Maximum
Signal Generator
output to transmission
loop antenna
( standard required loop)
:
5mV/m(74dBu)
400Hz
MOD.30%
999kHz
(230,230RDS)
1000kHz
(120)
999kHz
(230,230RDS)
1000kHz(120)
Output level(L or R)
at
TAPE-OUT
Maximum
1
step
Input Signal Source
Connection
Signal
Frequency
Source Signal Output Level and
Modulation
Reception
Frequency
Adjustment
Point
Adjustment
Value
1
522kHz
(230,230RDS)
520kHz(120)
5mV/m(74dBu)
400Hz
MOD.30%
Signal Generator
output to transmission
loop antenna
(:standard required loop)
522kHz
(230,230RDS)
520kHz
(120)
(P9)
T802
1.1V 1.2V
4. AM OSC Adujstment
15mV 3mV
15mV 3mV
15mV 3mV
15mV 3mV
15mV 3mV
FRONT-L
FRONT-R
CENTER
SURR-L
SURR-R
VR401
VR402
VR501
VR601
VR602
R471
R472
R536
R671
R672
CHANNEL
ADJUSTING LOCATION
MEASURE LOC.
VOL. DROP
Page of 80