8. Immunity to ambient electromagnetic fields (S3)
8.1 Test criteria  and test procedure
Operating environment;
Temperature         
: 15 ℃
Relative Humidity  
: 45 %
The EUT was placed on a non-metallic support by 0.1m above the lower 
conductor in the center of the stripline.
The wanted signal was fed to all input terminals respectively .The unwanted 
signal is fed to a matching network of the stripline.
The ground connection of the mains filter(M) was directly connected to the
jacky.
All unused input/output connections on the EUT were terminated and 
shielded with the proper resistance.
The power supply to the mains of the EUT was attached to the mains filter(M).
Ferrite rings for this test was required on all test cables inside the shielded 
room.
The measurement are performed with TS9980 Version 2.9.
8.2 Measurement uncertainty
Radiated fields  : ± 2dB
8.3 Test result immunity from radiated fields.
The equipment does comply with the requirements.
For the measurement data, see annex D.
 Anam EMC Test Laboratory ▶
Reference No.: 54120703B
Page 9
9. Screening effectiveness(S4)
9.1 Test criteria and test procedure for VHF band II receiver.
Operating environment;
Temperature         
: 15 ℃
Relative Humidity  
: 40 %
The equipment under test was placed on a non-metallic table of height 0.8m.
At the side of the antenna input terminal of the equipment under test, a 
non-metallic table of length 4m was placed at the same height to provide
for movement of the measuring device, an absorbing clamp. 
An RF signal generator is placed on a third table.
The equipment under test is connected to the generator, but not connected to 
the mains supply.
The signal from the generator is at the test frequency and unmodulated.
9.2 Measurement uncertainty
Screen effective : ± 2dB
9.3 Test results screen effective
The equipment does comply with the requirements.
For the measurement data, see annex E.
 Anam EMC Test Laboratory ▶
Reference No.: 54120703B
Page10
10. Test instrumentation
 
Signal Generator(SMG)
R & S
835793/023
Signal Generator(SMG)
R & S
835793/024
Signal Generator(SMX)
R & S
837283/004
TV Patter Generator(SGPF)
R & S
835773/001
Sound Tone(41.25MHz)(SBUF-E2)
R & S
837859/001
TV Test Transmitter(SBUF)
R & S
861456/025
RF Step attenuator(139dB)(DPSP)
R & S
836731/003
Millivolt Meter(URV5)
R & S
837256/001
Harmonic filter(ATS-OW)
R & S
316977/003
Bandpass filter(0.5-3kHz)(BP)
Erika Fiedler
6229
Isolation Transformer(TS-TT.3)
Volrio Star
94/109738
Millivolt Meter(URV-3)
R & S
836364/007
AC Millivolt meter(LMV-189AR)
Leader Electronicx
1427669
RF Power AMP(1347F/325LA)
ENI
Audio Analyzer(UPA)
R & S
836798/010
RC Net Work(8,300ohm/RCo)
Erika Fiedler
Mains Filter(MSF)
Erika Fiedler
Coupling Unit(A,M,L,SR)
Erika Fiedler
Matching Net Work(MN)
Erika Fiedler
Mains Filter(M)
Erika Fiedler
Loudspeaker Filter(BS)
Erika Fiedler
RC Net Work(RCi,RCo)
Erika Fiedler
Signal Generator(MG3632A)
Anritsu Corp.
MT39628
 Anam EMC Test Laboratory ▶
Equipment and Type
Manufacturer
Serial NO.
Page of 127