Reference No. : 54120503C                                                                                                                        Page 15
 
◀  Anam EMC Test Laboratory  ▶
 
 
Limit(㏈㎺) Result(㏈㎺) 
Test Lead 
Freq. 
(㎒) 
QP AV QP  AV 
AC Power Cord 
77.51 
46.7 
36.7 
Headphone 215.04 
51.8 41.8 37.7 * 
S-Video Video4 
82.19 46.9  36.9  33.0 31.7 
S-Video Monitor out 
98.81 47.5  37.5  33.6 31.2 
S-Video DVD IN 
82.07 46.9  36.9  29.8 26.9 
S-Video Video1 IN 
82.06 46.9  36.9  28.0 26.8 
S-Video video1 Out 
81.94 46.9  36.9  30.6 28.6 
S-Video video2 IN 
81.85 46.9  36.9  29.4 28.0 
S-Video2 video2 Out 
81.60 46.9  36.9  29.5 27.8 
S-Video video3 IN 
98.53 47.5  37.5  35.2 33.5 
Video 4 
81.68 46.9  36.9  31.9 29.6 
Coaxial video4 
81.63 46.9  36.9 
* * 
Coaxial in 1,2,3 
80.01 46.8  36.8 
* * 
Coaxial Out 
80.00 46.8  36.8 
* * 
Component video Mon  108.31 47.8  37.8 
* * 
Component video2 
89.72 47.2  37.2 
* * 
Component DVD 
86.01 47.0  37.0 
* * 
8.1Ch IN FR,FL,C 
81.33 46.9  36.9 
* * 
8.1Ch IN SR,SL,SW 
81.33 46.9  36.9 
* * 
8.1Ch IN SBR,SBL 
81.33 46.9  36.9 
* * 
Preout FR,FL,C 
79.99 46.8  36.8 
* * 
Preout SR,SL,SW 
80.01 46.8  36.8 
* * 
Preout SBR,SBL 
80.01 46.8  36.8 
* * 
Multi out 
60.00 46.1  36.1 
CD IN 
30.42 45.0  35.0 
Tape OUT 
60.00 46.1  36.1 
Tape IN 
60.00 46.1  36.1 
Video3 IN 
60.00 46.1  36.1 
Video2 Out 
60.00 46.1  36.1 
Video2 IN 
60.00 46.1  36.1 
Video1 Out 
60.00 46.1  36.1 
Video1 IN 
60.00 46.1  36.1 
DVD IN 
60.00 46.1  36.1 
Monitor Out 
30.00 45.0  35.0 
Multi IN 
95.00 47.4  37.4 
Remote IN 
60.00 46.1  36.1 
Reference No. : 54120503C                                                                                                                        Page 16
 
◀  Anam EMC Test Laboratory  ▶
 
Remote Out 
60.00 46.1  36.1 
Speaker FR 
60.00 46.1  36.1 
Speaker FL 
60.00 46.1  36.1 
Speaker S/B Multi R 
60.00 46.1  36.1 
Speaker S/B Multi L 
60.00 46.1  36.1 
Speaker Surround R 
60.00 46.1  36.1 
Speaker Surround L 
60.00 46.1  36.1 
Speaker Center 
60.00 46.1  36.1 
 
 
 
 
 
 
*: less than 25 ㏈㎺
 
 
Note:1) The spectrum was checked from 30 to 300 ㎒. 
 
     2) The cable (6.0m length) loss is included in a correction factor. 
 
     3) Detector function of the measuring instrument:  
 
 
QP: Quasi-peak, AV: Average 
 
     4) QP line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 43.9 
 
              AV line: Limit (㏈㎺) = Frequency (㎒)  ×0.037 + 33.9 
 
     5) *: Less than 25 ㏈㎺ 
 
For the measurement data, see Annex B (44 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54120503C                                                                                                                        Page 17
 
◀  Anam EMC Test Laboratory  ▶
 
 
9. HARMONICS 
  9.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 40% 
 
    9.2. Test set-up and procedure 
 
Harmonics of the fundamental current were measured up to 2 ㎑ using a 
 
universal power analyzer. The measurement was carried out under steady   
 
conditions and using averaging. 
 
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2 : 2000. 
 
The measurement was performed with the Test software (Version 3.07.04)   
for Windows 
The input signal and load conditions were set as given in clause 4.2.4 of   
IEC 60065. 
 
   9.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Universal power analyzer  Voltech 
PM 3300 
AK19/1137 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
9.4. Test result 
 
The equipment does comply with the requirements. 
For the measurement data, see Annex C (3 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54120503C                                                                                                                        Page 18
 
◀  Anam EMC Test Laboratory  ▶
 
 
10. VOLTAGE FLUCTUATIONS-FLICKER 
   10.1. Operating environment 
Temperature 
: 18℃ 
Relative humidity  : 40% 
 
      10.2. Test set-up and procedure 
 
The open circuit test voltage was the rated voltage of the EUT. 
 
The reference impedance was a conventional impedance being used to calculate 
or measure the disturbance caused by an appliance. 
 
The measurement was performed with the Test software (Version 3.07.04)   
for Windows 
 
The input signal and load conditions were set as given in clause 4.2.4 of   
IEC 60065. 
 
   10.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Reference impedance 
Voltech 
IEC Standard 555 
IB16/0725 
Universal power analyzer  Voltech 
PM 3300 
AK19/1137 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
10.4. Test result 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex D (2 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 21