Harman Kardon AVR 335 EMC - CB Certificate ▷ View online
Reference No. : 54120503C Page 15
◀ Anam EMC Test Laboratory ▶
Limit(㏈㎺) Result(㏈㎺)
Test Lead
Freq.
(㎒)
QP AV QP AV
AC Power Cord
77.51
46.7
36.7
*
*
Headphone 215.04
51.8 41.8 37.7 *
S-Video Video4
82.19 46.9 36.9 33.0 31.7
S-Video Monitor out
98.81 47.5 37.5 33.6 31.2
S-Video DVD IN
82.07 46.9 36.9 29.8 26.9
S-Video Video1 IN
82.06 46.9 36.9 28.0 26.8
S-Video video1 Out
81.94 46.9 36.9 30.6 28.6
S-Video video2 IN
81.85 46.9 36.9 29.4 28.0
S-Video2 video2 Out
81.60 46.9 36.9 29.5 27.8
S-Video video3 IN
98.53 47.5 37.5 35.2 33.5
Video 4
81.68 46.9 36.9 31.9 29.6
Coaxial video4
81.63 46.9 36.9
* *
Coaxial in 1,2,3
80.01 46.8 36.8
* *
Coaxial Out
80.00 46.8 36.8
* *
Component video Mon 108.31 47.8 37.8
* *
Component video2
89.72 47.2 37.2
* *
Component DVD
86.01 47.0 37.0
* *
8.1Ch IN FR,FL,C
81.33 46.9 36.9
* *
8.1Ch IN SR,SL,SW
81.33 46.9 36.9
* *
8.1Ch IN SBR,SBL
81.33 46.9 36.9
* *
Preout FR,FL,C
79.99 46.8 36.8
* *
Preout SR,SL,SW
80.01 46.8 36.8
* *
Preout SBR,SBL
80.01 46.8 36.8
* *
Multi out
60.00 46.1 36.1
*
*
CD IN
30.42 45.0 35.0
*
*
Tape OUT
60.00 46.1 36.1
*
*
Tape IN
60.00 46.1 36.1
*
*
Video3 IN
60.00 46.1 36.1
*
*
Video2 Out
60.00 46.1 36.1
*
*
Video2 IN
60.00 46.1 36.1
*
*
Video1 Out
60.00 46.1 36.1
*
*
Video1 IN
60.00 46.1 36.1
*
*
DVD IN
60.00 46.1 36.1
*
*
Monitor Out
30.00 45.0 35.0
*
*
Multi IN
95.00 47.4 37.4
*
*
Remote IN
60.00 46.1 36.1
*
*
Reference No. : 54120503C Page 16
◀ Anam EMC Test Laboratory ▶
Remote Out
60.00 46.1 36.1
*
*
Speaker FR
60.00 46.1 36.1
*
*
Speaker FL
60.00 46.1 36.1
*
*
Speaker S/B Multi R
60.00 46.1 36.1
*
*
Speaker S/B Multi L
60.00 46.1 36.1
*
*
Speaker Surround R
60.00 46.1 36.1
*
*
Speaker Surround L
60.00 46.1 36.1
*
*
Speaker Center
60.00 46.1 36.1
*
*
*: less than 25 ㏈㎺
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex B (44 Copies).
Reference No. : 54120503C Page 17
◀ Anam EMC Test Laboratory ▶
9. HARMONICS
9.1. Operating environment
Temperature
: 18℃
Relative humidity : 40%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2 : 2000.
The measurement was performed with the Test software (Version 3.07.04)
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
Signal Generator
Anritsu
MG3632A
MT79870
Universal power analyzer Voltech
PM 3300
AK19/1137
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).
Reference No. : 54120503C Page 18
◀ Anam EMC Test Laboratory ▶
10. VOLTAGE FLUCTUATIONS-FLICKER
10.1. Operating environment
Temperature
: 18℃
Relative humidity : 40%
10.2. Test set-up and procedure
The open circuit test voltage was the rated voltage of the EUT.
The reference impedance was a conventional impedance being used to calculate
or measure the disturbance caused by an appliance.
or measure the disturbance caused by an appliance.
The measurement was performed with the Test software (Version 3.07.04)
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
10.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
Signal Generator
Anritsu
MG3632A
MT79870
Reference impedance
Voltech
IEC Standard 555
IB16/0725
Universal power analyzer Voltech
PM 3300
AK19/1137
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
10.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex D (2 Copies).
Click on the first or last page to see other AVR 335 service manuals if exist.