Harman Kardon AVR 330 (serv.man13) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 33 of 38 -
Order
No.
11152
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
For
CENELEC
Countries
CENELEC
Countries
Mains plug
with cord
with cord
Kenic Electric Mfg.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt. Phino
Electrical
Wire & Cable
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kuk Je Tong shin
KKJ-1004A
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Volex (Asia) Pte.
Ltd.
Ltd.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt. Korea
KDK KKP-419C
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kenic Electric Mfg.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
For U.K.
Mains plug
with cord
with cord
PHINO Electronics
Co., Ltd
Co., Ltd
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
(5A fused)
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
(5A fused)
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Winbo Industries
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
(5A fused)
6A/250V
BS1363
BS6500
BS6500
BSI
alt. Luen
Tai
(IP’S)
Elect.
Kenic Electric Mfg.
9518
H05VVH2-F
H05VVH2-F
13A/250V
(5A fused)
6A/250V
BS1363
BS6500
BS6500
BSI
Main
transformer
Bobbin
material
Thermal fuse
transformer
Bobbin
material
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Various
Therm-O-Disc.
Telecom Co., Ltd.
Various
Therm-O-Disc.
KLT5W011ZE/
CLT5W011ZE
PETP or
CLT5W011ZE
PETP or
equiv
.
G4A51167C
230V, Class E
94V-0
94V-0
10A/250V, 167
°
C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL
VDE
UL
VDE
Sub
transformer
Bobbin
material
Thermal fuse
transformer
Bobbin
material
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Various
Uchihashi Estec Co.
Telecom Co., Ltd.
Various
Uchihashi Estec Co.
KLT5J033ZE /
CLT5J033ZE
PETP or
CLT5J033ZE
PETP or
equiv.
423
230V, Class E
94V-0
94V-0
0.5A/250V 130
°
C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL
VDE
UL
VDE
SW01
Mains switch
POSTEC Electric.
SDL1P-B
5A/80A 250V
IEC60065
IEC61058-1
VDE
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 38 -
Order
No.
11152
LIST OF CRITICAL COMPONENTS (continued)
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
RY94
Mains relay
Original Electrome.
SDT-S-112DMR
8A/120A 250V
IEC60065
IEC61058-1
IEC61058-1
SEMKO
F901, F902
Outlet fuse
alt.
alt.
alt.
alt.
alt.
alt.
Littelfuse B.V.
Littelfuse Triad.
Bel Fuse.
Save Fusetech.
Littelfuse Triad.
Bel Fuse.
Save Fusetech.
0663
LT-5
MRT
SR-5
LT-5
MRT
SR-5
T2.5A 250V
IEC60127
VDE
SEMKO
VDE
VDE
SEMKO
VDE
VDE
F903, F904
Sec. fuse
alt.
alt.
S
amjoo Fuse Co. Ltd.
Littelfuse Inc.
S51
218
218
008
SB 8A 250V
UL198G
UL
UL
UL
F905, F906
Mains fuse
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Samjoo Fuse Co.
Littelfuse Ltd.
Littelfuse B.V.
Suzhou
Littelfuse Ltd.
Littelfuse B.V.
Suzhou
Littelfuse OVS
Littelfuse Triad Inc.
50T
218
218
06.3
218
06.3
618
50T
50T
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
SEMKO
VDE
VDE
VDE
SEMKO
F907 Mains
fuse
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Samjoo Fuse Co.
Littelfuse Ltd.
Littelfuse B.V.
Suzhou
Littelfuse Ltd.
Littelfuse B.V.
Suzhou
Littelfuse OVS
Littelfuse Triad Inc.
50T
218
218
004
218
004
618
50T
50T
T4A L 250V
IEC60127
VDE
VDE
VDE
VDE
SEMKO
VDE
VDE
VDE
SEMKO
C124 X-capacitor
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
PCX2 335M
KNB1530
RE104
WBU1942
KNB1530
RE104
WBU1942
0.10uF 275V
X2
X2
IEC60384-
14, 2
14, 2
nd
ed.
FIMKO
FIMKO
VDE
FIMKO
FIMKO
VDE
FIMKO
C853
(switch across)
C904
(relay across)
X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC
60384-
14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
OL91 Mains
Socket-outlet
Dae Ryung
Electronics.
Electronics.
A3-04-D006 2.5A/250V IEC60884-1
NEMKO
DC
Brush-
less Fan
SUNONWEALTH
Electric Machine.
Electric Machine.
KD1206PTS3 DC12V,
0.8A
16 CFM
IEC60950 TUV
PCB
base
material
Various
Various
Min 94V-1
UL 796
UL
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 35 of 38 -
Order
No.
11152
FAULT CONDITION TESTS
P
Ambient temperature
25,5 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D104
S-c
254,4
A - C
30 min
F907
1,85 A
Normal operating.
Input current stabilised at 1,78A.
R106
Input current stabilised at 1,78A.
R106
opened. No hazard.
C122
S-c
254,4
-
4 hr
F907
2,18 A
FL display off immediately.
Input current stabilised at 1,94A.
R101 damaged.
Main transformer primary winding
heated-up to 130K and stabilised.
Dielectric strength test O.K.
No hazard.
Input current stabilised at 1,94A.
R101 damaged.
Main transformer primary winding
heated-up to 130K and stabilised.
Dielectric strength test O.K.
No hazard.
Q104
S-c
254,4
C - E
1 hr
F907
1,84 A
Normal operating.
Input current stabilised at 1,80A.
No component damaged.
No hazard.
Input current stabilised at 1,80A.
No component damaged.
No hazard.
Q104
S-c
254,4
B - C
4 hr
F907
2,15 A
FL display off immediately.
Input current stabilised at 1,97A.
R101, Q104, D101, D102 damaged.
Main transformer primary winding
heated-up to 123K and stabilised.
Dielectric strength test O.K.
No hazard.
Input current stabilised at 1,97A.
R101, Q104, D101, D102 damaged.
Main transformer primary winding
heated-up to 123K and stabilised.
Dielectric strength test O.K.
No hazard.
C119
S-c
254,4
-
3 hr
F907
2,00 A
FL display off immediately.
Input current stabilised at 1,96A.
Q104 damaged.
Main transformer primary winding
heated-up to 116K and stabilised.
Dielectric strength test O.K.
No hazard.
Input current stabilised at 1,96A.
Q104 damaged.
Main transformer primary winding
heated-up to 116K and stabilised.
Dielectric strength test O.K.
No hazard.
C117
S-c
254,4
-
20 min
F907
1,79 A
Normal operating.
Input current stabilised at 1,79A.
No component damaged.
No hazard.
Input current stabilised at 1,79A.
No component damaged.
No hazard.
D991
S-c
207
AC - +
10 min
F907
F903
F904
F903
F904
- Normal
operating.
Input current stabilised at 1,64A.
F904 opened. No hazard.
F904 opened. No hazard.
D991
S-c
254,4
AC - +
10 min
F907
F903
F904
F903
F904
- Normal
operating.
Input current stabilised at 1,76A.
F904 opened. No hazard.
F904 opened. No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 36 of 38 -
Order
No.
11152
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
C902 S-c
207 -
10
min
F907
F903
F904
F903
F904
-
Front, SB/MULTI channels signal
output off immediately.
Input current stabilised at 0,85 A.
F903, F904 opened.
No hazard.
output off immediately.
Input current stabilised at 0,85 A.
F903, F904 opened.
No hazard.
C902 S-c
254,4 -
10
min
F907
F903
F904
F903
F904
-
Front, SB/MULTI channels signal
output off immediately.
Input current stabilised at 0,89 A.
F903, F904 opened.
No hazard.
output off immediately.
Input current stabilised at 0,89 A.
F903, F904 opened.
No hazard.
D992
S-c
207
AC - +
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,70A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
S-c
254,4
AC - +
10 min
F907
F905
F906
F905
F906
- Normal
operating.
Input current stabilised at 1,78A.
F906 opened.
No hazard.
F906 opened.
No hazard.
C915 S-c
254,4 -
10
min
F907
F905
F906
F905
F906
-
Center, Surround channels signal
output off immediately.
Input current stabilised at 1,21A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 1,21A.
F905, F906 opened.
No hazard.
Q803
S-c
207
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Q803
S-c
254,4
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Q803
S-c
254,4
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C807 S-c
254,4 -
20
min
F907
F905
F906
F905
F906
2,16 A
Surround L channel signal output
distorted immediately.
Input current stabilised at 1,61A.
R821 opened.
No hazard.
distorted immediately.
Input current stabilised at 1,61A.
R821 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 330 (serv.man13) service manuals if exist.