Reference No. : 54120704C                                                                                                                        Page 12
 
◀  Anam EMC Test Laboratory  ▶
 
 
7.5. Test protocols 
 
Date: June 15, 2007 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
98.2 
54.0 
38.3 
 2 
196.4 
50.0 
32.8 
 3 
294.6 
50.0 
 4 
392.8 
52.0 
87.5 5 491.0 
52.0 * 
 6 
589.2 
52.0 
36.4 
 7 
687.4 
52.0 
50.1 
 8 
785.6 
52.0 
 9 
883.8 
52.0 
 10 
982.0 
52.0 * 
 1 
100.8 
54.0 
38.5 
 2 
201.6 
50.0 
32.8 
 3 
302.4 
52.0 
 4 
403.2 
52.0 
90.1 5 504.0 
52.0 * 
 6 
604.8 
52.0 
33.5 
 7 
705.6 
52.0 
37.9 
 8 
806.4 
52.0 
 9 
907.2 
52.0 
 1 
108.7 
54.0 
39.1 
 2 
217.4 
50.0 
33.4 
 3 
326.1 
52.0 
30.1 
98.0 4 434.8 
52.0 * 
 5 
543.5 
52.0 
30.7 
 6 
652.2 
52.0 
29.3 
 7 
760.9 
52.0 
36.1 
 8 
869.6 
52.0 
 9 
978.3 
52.0 
 
 
Reference No. : 54120704C                                                                                                                        Page 13
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
110.8 
54.0 
39.3 
 2 
221.6 
50.0 
32.5 
 3 
332.4 
50.0 
31.0 
 4 
443.2 
52.0 
100.1 5 554.0 
52.0 33.4 
 6 
664.8 
52.0 
29.6 
 7 
775.6 
52.0 
35.8 
 8 
886.4 
52.0 
 9 
997.2 
52.0 
 1 
116.8 
54.0 
39.8 
 2 
233.6 
50.0 
32.83 
 3 
350.4 
52.0 
32.1 
 4 
467.2 
52.0 
106.1 5 584.0 
52.0 39.2 
 6 
700.8 
52.0 
31.6 
 7 
817.6 
52.0 
37.3 
 8 
934.4 
52.0 
 1 
118.7 
54.0 
40.0 
 2 
237.4 
50.0 
33.0 
 3 
356.1 
52.0 
31.9 
108.0 4 474.8 
52.0  * 
 5 
593.5 
52.0 
38.2 
 6 
712.2 
52.0 
31.3 
 7 
830.9 
52.0 
38.6 
 8 
949.6 
52.0 
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
98.0   / 46.0 * 
 
*: less than 30 ㏈㎶  
 
                                            Limit according to EN55013:2001 
Reference No. : 54120704C                                                                                                                        Page 14
 
◀  Anam EMC Test Laboratory  ▶
 
 
8. DISTURBANCE POWER 
8.1. Operating environment 
Temperature 
: 26℃ 
Relative humidity  : 55% 
 
      8.2. Test set-up and procedure 
 
The EUT was placed on a non-metallic table of 0.8m height. At the side of the 
 
EUT a non-metallic table of 6m length was placed to provide for movement of 
 
the absorbing clamp. The absorbing clamp was applied successively to all leads 
 
whose length was 25 ㎝  or longer, unscreened or screened. For the read, the 
 
maximum measured value at each frequency which was obtained when the 
 
absorbing clamp is moved along the lead was registered. No metallic object, 
 
including a possible other unit of the EUT or any person, was closer to the lead 
 
or unit than 0.8m. All screened and unscreened cables were measured with an 
absorbing clamp, according to EN 55013, 5.6. 
 
   8.3. Measurement uncertainty 
 
Radio interference power:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
   8.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Spectrum monitor 
R & S 
EZM 
862064/004 
R & S 
ESVP 
861743/024 
Measurement 
receiver 
R & S 
ESCI 
100348 
Absorbing clamp 
R & S 
MDS 21 
860846/006 
Oscillator Kenwood 
AG-203A 
3090241 
 
* R & S: Rohde & Schwarz 
 
8.5. Test protocols 
 
Date: June 12, 2007 
 
The equipment does comply with the requirements. 
 
Operating condition: The EUT continuously operated with audio frequency 
of 1,000 ㎐  being supplied from the Oscillator. 
An absorbing clamp was placed around all leads.   
At each mode, the maximum value at each testing frequency and each output 
lead was registered and attached as follows. 
 
Reference No. : 54120704C                                                                                                                        Page 15
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
Limit(㏈㎺) Result(㏈㎺) 
Test Lead 
Freq. 
(㎒) 
QP AV QP  AV 
CD IN 
58.36 
46.0 
36.0 
TAPE OUT 
122.88
48.4 38.4 25.2  24.3 
TAPE IN 
122.88
48.4 38.4 24.1  24.1 
VID3 IN 
58.36 
46.0 36.0  * 
VID2 IN 
58.36 
46.0 36.0  * 
VID1 OUTt 
58.36 
46.0 36.0  * 
VID1 IN 
58.36 
46.0 36.0  * 
DVD IN 
58.36 
46.0 36.0  * 
6CH FL/FR 
58.36 
46.0 36.0 27.6  27.5 
6CH SL/SR 
58.36 
46.0 36.0 27.6  26.5 
6CH C/SW 
58.36 
46.0 36.0 28.4  27.8 
8CH SBL/SBR 
58.36 
46.0 36.0 31.2  30.5 
Video Monitor Out 
58.36 
46.0 36.0  * 
Component Video In1 
122.88
48.4 38.4  * 
Component Video In2 
122.88
48.4 38.4  * 
Component Video In3 
122.88
48.4 38.4   
 
      “    Monitor Out 
122.88
48.4 38.4  * 
Coaxial Out 
122.88
48.4 38.4  * 
Coaxial 1 
122.88
48.4 38.4  * 
Coaxial 2 
122.88
48.4 38.4  * 
PRE-OUT FL/FR 
122.88
48.4 38.4 25.1  23.2 
PRE-OUT SL/SR 
122.88
48.4 38.4 25.3  24.2 
PRE-OUT C/SUB 
122.88
48.4 38.4 25.2  24.3 
PRE-OUT SBL/SBR 
122.88
48.4 38.4 25.2  23.6 
MULTI IN 
122.88
48.4 38.4 27.3  25.7 
REMOTE IN 
122.88
48.4 38.4 26.2  25.1 
REMOTE OUT 
122.88
48.4 38.4 25.4  23.6 
S-Video VID3 IN 
58.36 
46.0 36.0  * 
S-Video VID2 IN 
58.36 
46.0 36.0  * 
S-Video VID1 OUT 
58.36 
46.0 36.0  * 
S-Video VID1 IN 
58.36 
46.0 36.0  * 
S-Video DVD IN 
58.36 
46.0 36.0  * 
S-Video Monitor out 
58.36 
46.0 36.0  * 
HDMI OUT 
122.88
48.4 38.4  * 
HDMI IN1 
122.88
48.4 38.4  * 
Page of 127