Harman Kardon AVR 247 (serv.man3) EMC - CB Certificate ▷ View online
Reference No. : 54120707D Page 10
◀ Anam EMC Test Laboratory ▶
9. Screening effectiveness(S4)
9.1 Test criteria and test procedure for VHF band II receiver.
Operating environment;
Temperature : 15 ℃
Relative Humidity : 50 %
Relative Humidity : 50 %
The equipment under test was placed on a non-metallic table of height 0.8m.
At the side of the antenna input terminal of the equipment under test, a
non-metallic table of length 4m was placed at the same height to provide
for movement of the measuring device, an absorbing clamp.
An RF signal generator is placed on a third table.
At the side of the antenna input terminal of the equipment under test, a
non-metallic table of length 4m was placed at the same height to provide
for movement of the measuring device, an absorbing clamp.
An RF signal generator is placed on a third table.
The equipment under test is connected to the generator, but not connected to
the mains supply.
The signal from the generator is at the test frequency and unmodulated.
the mains supply.
The signal from the generator is at the test frequency and unmodulated.
9.2 Measurement uncertainty
Screen effective : ± 2dB
9.3 Test results screen effective
The equipment does comply with the requirements.
For the measurement data, see annex E.
Reference No. : 54120707D Page 11
◀ Anam EMC Test Laboratory ▶
10. Test instrumentation
Equipment and Type
Manufacturer
Serial NO.
Signal Generator(SMG)
R & S
835793/023
Signal Generator(SMG)
R & S
835793/024
Signal Generator(SMX)
R & S
837283/004
TV Patter Generator(SGPF)
R & S
835773/001
Sound Tone(41.25MHz)(SBUF-E2)
R & S
837859/001
TV Test Transmitter(SBUF)
R & S
861456/025
RF Step attenuator(139dB)(DPSP)
R & S
836731/003
Millivolt Meter(URV5)
R & S
837256/001
Harmonic filter(ATS-OW)
R & S
316977/003
Bandpass filter(0.5-3kHz)(BP)
Erika Fiedler
6229
Isolation Transformer(TS-TT.3)
Volrio Star
94/109738
Millivolt Meter(URV-3)
R & S
836364/007
AC Millivolt meter(LMV-189AR)
Leader Electronicx
1427669
RF Power AMP(1347F/325LA)
ENI
Audio Analyzer(UPA)
R & S
836798/010
RC Net Work(8,300ohm/RCo)
Erika Fiedler
Mains Filter(MSF)
Erika Fiedler
Coupling Unit(A,M,L,SR)
Erika Fiedler
Matching Net Work(MN)
Erika Fiedler
Mains Filter(M)
Erika Fiedler
Loudspeaker Filter(BS)
Erika Fiedler
RC Net Work(RCi,RCo)
Erika Fiedler
Signal Generator(MG3632A)
Anritsu Corp.
MT39628
Reference No. : 54120707D Page 12
◀ Anam EMC Test Laboratory ▶
11. Photograph of Equipnent
11.1 TS9980 EMS Test System
Reference No. : 54120707D Page 13
◀ Anam EMC Test Laboratory ▶
12. Photograph of The Test Set-up
12.1 S1 : Immunity to input interference Set-up
12.2 S2a : Immunity to RFI voltages Set-up
Click on the first or last page to see other AVR 247 (serv.man3) service manuals if exist.