Reference No. : 54120707D                                                                                                                        Page 10
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
9. Screening effectiveness(S4) 
 
9.1 Test criteria and test procedure for VHF band II receiver. 
 
Operating environment; 
          Temperature                  : 15  ℃   
          Relative Humidity        : 50 % 
 
 
The equipment under test was placed on a non-metallic table of height 0.8m. 
At the side of the antenna input terminal of the equipment under test, a   
non-metallic table of length 4m was placed at the same height to provide 
for movement of the measuring device, an absorbing clamp.   
An RF signal generator is placed on a third table. 
 
The equipment under test is connected to the generator, but not connected to   
the mains supply. 
The signal from the generator is at the test frequency and unmodulated. 
 
 
9.2 Measurement uncertainty 
 
Screen effective : ± 2dB 
 
 
9.3 Test results screen effective 
 
The equipment does comply with the requirements. 
 
For the measurement data, see annex E. 
 
 
 
 
 
 
 
Reference No. : 54120707D                                                                                                                        Page 11
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
10. Test instrumentation 
 
Equipment and Type 
Manufacturer 
Serial NO. 
Signal Generator(SMG) 
R & S 
 
835793/023 
Signal Generator(SMG) 
R & S 
 
835793/024 
Signal Generator(SMX) 
R & S 
 
837283/004 
TV Patter Generator(SGPF) 
R & S 
 
835773/001 
Sound Tone(41.25MHz)(SBUF-E2) 
R & S 
 
837859/001 
TV Test Transmitter(SBUF) 
R & S 
 
861456/025 
RF Step attenuator(139dB)(DPSP) 
R & S 
 
836731/003 
Millivolt Meter(URV5) 
R & S 
 
837256/001 
Harmonic filter(ATS-OW) 
R & S 
 
316977/003 
Bandpass filter(0.5-3kHz)(BP) 
Erika Fiedler 
6229 
Isolation Transformer(TS-TT.3) 
Volrio Star 
94/109738 
Millivolt Meter(URV-3) 
R & S 
 
836364/007 
AC Millivolt meter(LMV-189AR) 
Leader Electronicx 
1427669 
RF Power AMP(1347F/325LA) 
ENI 
   
 
Audio Analyzer(UPA) 
R & S 
 
836798/010 
RC Net Work(8,300ohm/RCo) 
Erika Fiedler 
 
 
Mains Filter(MSF) 
Erika Fiedler 
 
 
Coupling Unit(A,M,L,SR) 
Erika Fiedler 
 
 
Matching Net Work(MN) 
Erika Fiedler 
 
 
Mains Filter(M) 
Erika Fiedler 
 
 
Loudspeaker Filter(BS) 
Erika Fiedler 
 
 
RC Net Work(RCi,RCo) 
Erika Fiedler 
 
 
Signal Generator(MG3632A) 
Anritsu Corp. 
MT39628 
 
Reference No. : 54120707D                                                                                                                        Page 12
 
◀  Anam EMC Test Laboratory  ▶
 
11. Photograph of Equipnent
 
      11.1 TS9980 EMS Test System   
             
 
 
   
Reference No. : 54120707D                                                                                                                        Page 13
 
◀  Anam EMC Test Laboratory  ▶
 
 
12. Photograph of The Test Set-up 
 
      12.1 S1 : Immunity to input interference Set-up 
           
 
 
12.2 S2a : Immunity to RFI voltages Set-up 
 
Page of 127
Display