- Page 19 of 32 - 
 
 
www.nemko.com
 
Report No.  73226 
 
TRF No:  IEC/EN 60065F 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Approved mains plug and  
socket-outlet provided,  
see list of critical components. 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
Only phone/RCA, Mini jack, 
Optical, Antenna, HDMI, 
RS232 and S-video terminals 
used.  Banana plug type  
speaker terminal also used, 
but they areaccepted due to 
below note. 
 
Note:   
Banana plug type speaker  
terminals are blocked in their  
axial holes to prevent use of plugs 
that can make permanent contact 
with a mains socket outlet. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
No sockets indicated with the 
symbol 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets
The equipment under test is 
not an adaptor. 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II apparatus
 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 
 
Protective earth conductors correctly coloured 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
 
Protective earth terminal resistant to corrosion 
 
 
Earth resistance  test: < 0,1 Ω at 25 A ................... :
 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
Apparatus is not for permanent 
connection. 
15.3.2 
Reliable connection of non-detachable cords: 
 
 
 
- Page 20 of 32 - 
 
 
www.nemko.com
 
Report No.  73226 
 
TRF No:  IEC/EN 60065F 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Not soldered to conductors of a printed circuit 
board 
Not soldered. 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
Wires are clamped two times 
to the contact terminal and  
provided with a two-pole  
connector. 
 
Wire secured by additional means to the conductor
Adequately anchored.  
Tested with 5 N. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
No screws and nuts clamping.  
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
No soldered conductors. 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Clamped insulators and  
conductors.
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
Terminals have adequate 
connection capacity. 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
No contact pressure 
transmitted through insulating. 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
The termination of the 
contacts are in adequate 
proximity to each other. 
 
Terminals located and shielded: test with 8 mm 
strand 
Clamped contacts within 
connector 
15.4 
Devices forming a part of the mains plug 
 N 
15.4.1 
No undue strain on mains socket-outlets 
The apparatus is not a device 
forming a part of the mains 
plug. 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
 
 
- Page 21 of 32 - 
 
 
www.nemko.com
 
Report No.  73226 
 
TRF No:  IEC/EN 60065F 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 
 
 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................ :
Sheathed PVC cord 
complying with IEC 60227 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Class II apparatus 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
The cord is 0,75mm², within the 
current rating. 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of  
equipment used in combination and carrying  
hazardous live voltages, have adequate dielectric 
strength 
No interconnecting cables 
comprising hazardous live 
conductors. 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
Cord complying with 16.1.
 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
Cords have adequate cross-
sectional areas to avoid 
temperature rise under normal 
and fault conditions. 
16.5 
Adequate strain relief on external flexible cords 
Cord clip wedged in the  
enclosure. 
 
Not possible to push cord back into equipment 
Checked by inspection. 
 
Strain relief device unlikely to damage flexible cord
No sharp edges. 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
Class II apparatus. 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
No sharp edges. 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
The apparatus is not a 
transportable musical 
instrument and amplifier. 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
The apparatus is not a 
transportable musical 
instrument and amplifier. 
 
 
- Page 22 of 32 - 
 
 
www.nemko.com
 
Report No.  73226 
 
TRF No:  IEC/EN 60065F 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
17 ELECTRICAL 
CONNECTIONS 
AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
Screws fixing chassis to the 
main enclosure tested. 
 
- screws into metal: 5 times 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
 
- screws into non-metallic material: 10 times 
 
17.2 
Correct introduction into female threads in non-
metallic material 
No female threads in non-
metallic materials. 
17.3 
Cover fixing screws: captive 
Captivity not necessary. 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
Tested with screw with 10 times 
diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
Loosening is sufficiently  
prevented. 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals. 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No cover fixing devices other  
than screws. 
17.8 
Fixing devices for detachable legs or stands 
provided 
No detachable provided. 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Connections complies, 
checked by inspection 