Harman Kardon AVR 240 (serv.man12) EMC - CB Certificate ▷ View online
- Page 2 of 7 -
Order No. 46232
SUMMARY OF TESTING:
The apparatus complies with the requirements in IEC 60065:1998 and EN 60065:1998 with the following remarks.
This appendix test report, 46232 is covering the added variant model, AVR 240/230.
The model, AVR 240/230 is identical to earlier certified model AVR 235/230, except for equipped transformer type.
New transformer type, KLT5W011YE / CLT5W011YE and KLT5J033YE / CLT5J033YE for model AVR 240/130
have different thermel fuse type with previous one (see list of critical components), but equal to the previous models
in safety point of view, no additional tests is necessary.
have different thermel fuse type with previous one (see list of critical components), but equal to the previous models
in safety point of view, no additional tests is necessary.
This appendix test report 46232, must always be presented together with the main test report 11152 and appendixes
12250, 14081 and 34137.
12250, 14081 and 34137.
Clause Information/Remarks
Comments
- Page 3 of 7 -
Order No. 46232
5
MARKING AND INSTRUCTIONS
P
Copy of the markings (continued) :
Comprehensible and easily
discernible
discernible
On front and rear side of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
P
Class II symbol
N
Rated supply voltage and symbol
AC-symbol (
~
) and
230V
P
Rated mains frequency
50Hz
P
Rated current or power
consumption
consumption
350W
P
- Page 4 of 7 -
Order No. 46232
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
For
CENELEC
Countries
CENELEC
Countries
Mains plug
with cord
with cord
Kenic Electric Mfg.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt. Phino
Electrical
Wire & Cable
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kuk Je Tong shin
KKJ-1004A
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Volex (Asia) Pte.
Ltd.
Ltd.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt. Korea
KDK KKP-419C
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
alt.
Kenic Electric Mfg.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1
VDE
For U.K.
Mains plug
with cord
with cord
PHINO Electronics
Co., Ltd
Co., Ltd
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Volex (Asia) Pte Ltd.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
Winbo Industries
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. L
uen Tai (IP’S)
Elect
.
Kenic Electric Mfg.
9518
H05VVH2-F
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
Main
transformer
Bobbin
material
Thermal fuse
transformer
Bobbin
material
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Various
Therm-O-Disc.
Telecom Co., Ltd.
Various
Therm-O-Disc.
KLT5W011ZE/
CLT5W011ZE
PETP or
CLT5W011ZE
PETP or
equiv
.
G4A51167C
230V, Class E
94V-0
94V-0
10A/250V, 167
°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL
VDE
UL
VDE
*) Main
transformer
Bobbin
material
T
Bobbin
material
T
hermal fuse
Seoul Electronics
& Telecom Co.
Wintech Polymer
Therm-O-Disc.
& Telecom Co.
Wintech Polymer
Therm-O-Disc.
KLT5W011YE/
CLT5W011YE
CN9030
E4A51167C
CLT5W011YE
CN9030
E4A51167C
230V, Class E
PET
, V-0, 155
°
C
10A/250V, 167
°C
IEC60065
clause
14.3
UL94
IEC60691
1.)
UL,
(
UL,
(
E213445)
VDE
*) Added components for model, AVR 240/230 (bold)
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
Click on the first or last page to see other AVR 240 (serv.man12) service manuals if exist.