Reference No.: 54121302H
Page 6/34
6. Immunity to RF voltages(S2a)
6.1 Test criteria and test procedure
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 42 %
The EUT was placed 0.1m above a metallic ground plane of dimensions 2 x1m.
The wanted signal was fed to all input terminals respectively and the 
unwanted signal was fed to mains input, audio output and input terminals 
respectively.
The criterion concerning acceptable sound interference is a wanted to 
unwanted audio signal ratio of ≥40dB at a wanted signal level of 50mW.
The audio output power was measured with a 0.5 - 3kHz band-pass filter.
The audio analyzer was applied without a weighting filter.
The ground connection of the input matching network(Rci), output matching 
network(Rco), and mains filter(MSF) were directly connected to the metal table.
The mains filter(MSF) was connected to ground while the other matching 
networks are only connected to ground when they are being used as injection 
ports.
The measurement are performed with TS9980 
6.2 Measurement uncertainty
Immunity to conducted voltage : ± 2dB.
6.3 Test result immunity to conducted voltage.
The equipment does comply with the requirements.
For the measurement data, see annex B.
 Anam EMC Test Laboratory ▶
Reference No.: 54121302H
Page 7/34
7. Immunity to RF voltages (in common mode)(S2b)
7.1 Test criteria  and test procedure
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 42 %
During the test of immunity to RF voltages(in common mode), the EUT was 
placed 0.1m above a metallic ground plane of dimensions 2 x 1m.
The criterion concerning acceptable sound interference is a wanted to 
unwanted audio signal ratio of ≥40dB at a wanted signal level of 50mW
The requirements for receivers,multifuction equipment and video tape 
equipment concerning the immunity to RF voltages in common mode are 
restricted to the antenna terminals and to the frequency range from 26㎒ to
30㎒. The cables linking the coupling units to the EUT was short .
A bandpass filter was connected to the test system and was used for the EUT 
AF outputs.
All unused inputs/outputs of the coupling units was terminated with the 
proper resistance.
The power cable of the EUT was uniformly bundled together and as short
as possible.
The measurement are performed with TS9980 
7.2 Measurement uncertainty
Immunity to conducted currents : ± 2dB
7.3 Test result immunity to conducted currents.
The equipment does comply with the requirements.
For the measurement data,  see annex C.
 Anam EMC Test Laboratory ▶
Reference No.: 54121302H
Page 8/34
8. Immunity to ambient electromagnetic fields (S3)
8.1 Test criteria  and test procedure
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 42 %
The EUT was placed on a non-metallic support by 0.1m above the lower 
conductor in the center of the stripline.
The wanted signal was fed to all input terminals respectively .The unwanted 
signal is fed to a matching network of the stripline.
The ground connection of the mains filter(M) was directly connected to the
jacky.
All unused input/output connections on the EUT were terminated and 
shielded with the proper resistance.
The power supply to the mains of the EUT was attached to the mains filter(M).
Ferrite rings for this test was required on all test cables inside the shielded 
room.
The measurement are performed with TS9980 
8.2 Measurement uncertainty
Radiated fields  : ± 2dB
8.3 Test result immunity from radiated fields.
The equipment does comply with the requirements.
For the measurement data, see annex D.
 Anam EMC Test Laboratory ▶
Reference No.: 54121302H
Page 9/34
9. Screening effectiveness(S4)
9.1 Test criteria and test procedure for VHF band II receiver.
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 42 %
The equipment under test was placed on a non-metallic table of height 0.8m.
At the side of the antenna input terminal of the equipment under test, a 
non-metallic table of length 4m was placed at the same height to provide
for movement of the measuring device, an absorbing clamp. 
An RF signal generator is placed on a third table.
The equipment under test is connected to the generator, but not connected to 
the mains supply.
The signal from the generator is at the test frequency and unmodulated.
9.2 Measurement uncertainty
Screen effective : ± 2dB
9.3 Test results screen effective
The equipment does comply with the requirements.
For the measurement data, see annex E.