Harman Kardon AVR 170 (serv.man4) EMC - CB Certificate ▷ View online
Anam Electronics Co., Ltd. Page 13 of 61
AVR 170/230
EMC Test Report
Reference No.: NK-12-E-341
●EN 61000-3-2:2006+A1: 2009+A2: 2009:
Electromagnetic compatibility(EMC)-Pt.3: Limits-S.2: Limits for harmonic-current emissions
(equipment input current and including 16A)
Phenomena Basic
Standards
Result
Steady State Harmonics
EN 61000-3-2: 2006+A1: 2009+A2: 2009
N/A
Fluctuating Harmonics
EN 61000-3-2: 2006+A1: 2009+A2: 2009
Pass
●EN 61000-3-3: 2008:
Electromagnetic compatibility(EMC)-Pt.3: Limits-S.3: Limits for voltage fluctuations and flicker
in low voltage supply systems for equipment with rated current up to and including 16A.
Phenomena Basic
Standards
Result
Flicker EN
61000-3-3:
2008
Pass
Voltage Fluctuations
EN 61000-3-3: 2008
N/A
5.2 Deviations and Evaluations
●No recorded deviations to the applied standards.
●No general evaluations made.
Anam Electronics Co., Ltd. Page 14 of 61
AVR 170/230
EMC Test Report
Reference No.: NK-12-E-341
6. Conducted Disturbance at the Mains Port
6.1 Test Procedure
The measurements were performed in a shielded enclosure. EUT was connected to an Artificial
Mains Network (AMN). EUT was placed on a wooden table 0.8 m above the grounded floor and at
least 0.4 m from the reference ground plane (wall), EUT was placed at least 0.8 m from, and
connected via a 1 m mains cable, to the AMN.
The measurements on the terminals for mains connection were conducted between neutral and ground,
and between phase and ground, in the frequency range 150 kHz to 30 MHz.
A peak detector scan was conducted over the defined frequency range on all phases. A comparison
of the results obtained from the different phases was then conducted to find the most emitting phase
for each frequency. This “Worst Case” scan with quasi-peak detector & average detector was presented
detector. Instrumentation used during this session:
Instruments Manufacturer
Model
Serial or Firmware
(No./Ver.)
(No./Ver.)
Due to
Calibration
Calibration
EMI Test Receiver
Rohde & Schwarz
ESCI
101041
2013.04
Software Rohde
&
Schwarz
EMC32
8.40.0
-
TWO-LINE
V-NETWORK
V-NETWORK
Rohde & Schwarz
ENV216
101156
2013.04
Artificial Mains
Network
Network
Rohde & Schwarz
ESH2-Z5
100273
2013.04
ISN TESEQ
GMBH
ISN
T400
24330
2013.04
6.2 Measurement Uncertainty
Mismatch - 0.89, u
c
= 0.69 dB
U = 0.69 x 2 = 1.38 dB
U = ku
U = ku
c
(CL is 95 %, k = 2)
6.3 Test Parameters
Port:
a.c. mains Test
Engineer:
Ki wang, Kim
Test Standard:
EN 55022: 2006+A1: 2007 (Class B),
EN 55013: 2001+A1: 2003+A2: 2006
Frequency Range:
Frequency Step: IF
Bandwidth: Measurement
Time:
150 kHz – 30 MHz
5 kHz
9 kHz
0.2 s
Anam Electronics Co., Ltd. Page 15 of 61
AVR 170/230
EMC Test Report
Reference No.: NK-12-E-341
6.4 Test Data
① USB mode
Anam Electronics Co., Ltd. Page 16 of 61
AVR 170/230
EMC Test Report
Reference No.: NK-12-E-341
Tested by: Ki wang, Kim
Click on the first or last page to see other AVR 170 (serv.man4) service manuals if exist.