DOWNLOAD Harman Kardon AVR 170 (serv.man4) Service Manual ↓ Size: 3.17 MB | Pages: 61 in PDF or view online for FREE

Model
AVR 170 (serv.man4)
Pages
61
Size
3.17 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-170-sm4.pdf
Date

Harman Kardon AVR 170 (serv.man4) EMC - CB Certificate ▷ View online

 
Anam Electronics Co., Ltd.                                            Page 13 of 61 
                                  AVR 170/230
 
EMC Test Report 
Reference No.: NK-12-E-341 
EN 61000-3-2:2006+A1: 2009+A2: 2009: 
Electromagnetic compatibility(EMC)-Pt.3: Limits-S.2: Limits for harmonic-current emissions   
        (equipment input current and including 16A) 
Phenomena Basic 
Standards 
Result 
Steady State Harmonics 
EN 61000-3-2: 2006+A1: 2009+A2: 2009 
N/A 
Fluctuating Harmonics 
EN 61000-3-2: 2006+A1: 2009+A2: 2009 
Pass 
 
      ●EN 61000-3-3: 2008: 
    Electromagnetic compatibility(EMC)-Pt.3: Limits-S.3: Limits for voltage fluctuations and flicker   
        in low voltage supply systems for equipment with rated current up to and including 16A. 
Phenomena Basic 
Standards 
Result 
Flicker EN 
61000-3-3: 
2008 
Pass 
Voltage Fluctuations 
EN 61000-3-3: 2008 
N/A 
 
5.2 Deviations and Evaluations 
       
        ●No recorded deviations to the applied standards. 
        ●No general evaluations made. 
 
 
Anam Electronics Co., Ltd.                                            Page 14 of 61 
                                  AVR 170/230
 
EMC Test Report 
Reference No.: NK-12-E-341 
6. Conducted Disturbance at the Mains Port 
 
6.1 Test Procedure 
     
 
        The measurements were performed in a shielded enclosure. EUT was connected to an Artificial   
        Mains Network (AMN). EUT was placed on a wooden table 0.8 m above the grounded floor and at 
        least 0.4 m from the reference ground plane (wall), EUT was placed at least 0.8 m from, and   
        connected via a 1 m mains cable, to the AMN. 
        The measurements on the terminals for mains connection were conducted between neutral and ground,   
        and between phase and ground, in the frequency range 150 kHz to 30 MHz. 
        A peak detector scan was conducted over the defined frequency range on all phases. A comparison   
        of the results obtained from the different phases was then conducted to find the most emitting phase   
        for each frequency. This “Worst Case” scan with quasi-peak detector & average detector was presented   
detector. Instrumentation used during this session:     
Instruments Manufacturer 
Model 
Serial or Firmware   
(No./Ver.) 
Due to   
Calibration  
EMI Test Receiver 
Rohde & Schwarz 
ESCI 
101041 
2013.04 
Software Rohde 
Schwarz 
EMC32 
8.40.0 
TWO-LINE  
V-NETWORK 
Rohde & Schwarz 
ENV216 
101156 
2013.04 
Artificial Mains   
Network 
Rohde & Schwarz 
ESH2-Z5 
100273 
2013.04 
ISN TESEQ 
GMBH 
ISN 
T400 
24330 
2013.04 
 
6.2 Measurement Uncertainty 
 
Mismatch - 0.89, u
c
 = 0.69 dB 
U = 0.69 x 2 = 1.38 dB 
U = ku
c
 (CL is 95 %, k = 2)
 
 
 
 
6.3 Test Parameters 
 
Port: 
a.c. mains   Test 
Engineer: 
Ki wang, Kim 
Test Standard: 
EN 55022: 2006+A1: 2007 (Class B),   
 
EN 55013: 2001+A1: 2003+A2: 2006 
Frequency Range: 
Frequency Step: IF 
Bandwidth: Measurement 
Time: 
150 kHz – 30 MHz 
5 kHz 
9 kHz 
0.2 s 
 
 
 
 
 
 
 
 
 
 
 
Anam Electronics Co., Ltd.                                            Page 15 of 61 
                                  AVR 170/230
 
EMC Test Report 
Reference No.: NK-12-E-341 
 
6.4 Test Data   
 
 USB mode 
 
 
Anam Electronics Co., Ltd.                                            Page 16 of 61 
                                  AVR 170/230
 
EMC Test Report 
Reference No.: NK-12-E-341 
 
 
  Tested by: Ki wang, Kim 
Page of 61
Display