Harman Kardon AVR 161 (serv.man6) EMC - CB Certificate ▷ View online
Reference No. : 54121302E Page 21/45
◀ Anam EMC Test Laboratory ▶
12.3 Antenna Terminal Disturbance Voltage Test Set-up
12.4 Disturbance Power Set-up
Reference No. : 54121302E Page 22/45
◀ Anam EMC Test Laboratory ▶
Annex A: Mains terminal disturbance voltage
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
2 AV
CLRWR
SGL
1 PK
CLRWR
28.Jan 13 15:57
RBW
9 kHz
MT
1 s
PREAMP OFF
Att 25 dB
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
62.50 dBµV
150.000000000 kHz
A4_AV
A4_QP
AVR161/230_Ground line1(1KHz sine wave input FM 87.5MHz)
Date: 28.JAN.2013 15:57:30
Reference No. : 54121302E Page 23/45
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
2 AV
CLRWR
SGL
1 PK
CLRWR
RBW
9 kHz
MT
10 ms
PREAMP OFF
Att 25 dB
28.Jan 13 15:59
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
60.93 dBµV
150.000000000 kHz
A4_AV
A4_QP
AVR161/230_Ground line2(1KHz sine wave input FM 87.5MHz)
Date: 28.JAN.2013 15:59:54
Reference No. : 54121302E Page 24/45
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
2 AV
CLRWR
SGL
1 PK
CLRWR
RBW
9 kHz
MT
10 ms
PREAMP OFF
Att 25 dB
28.Jan 13 15:50
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
59.21 dBµV
150.000000000 kHz
A4_AV
A4_QP
AVR161/230_Nonground line1(1KHz sine wave input FM 87.5MHz)
Date: 28.JAN.2013 15:50:53
Click on the first or last page to see other AVR 161 (serv.man6) service manuals if exist.