Harman Kardon AVR 160 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120906E Page 8/60
◀ Anam EMC Test Laboratory ▶
6. DISTURBANCE RADIATION IN THE FREQUENCY RANGE 30MHz
TO 1,000MHz
6.1. Operating environment
Temperature
: 26℃
Relative humidity : 47%
6.2. Test set-up and procedure
The measurement was performed on an open area test site with a reference
ground plane and at a distance of 3m. The height of the measuring antenna was
varied between 1 to 4m and the table was rotated a full revolution in order to
obtain maximum value of the electric field intensity. The measurement was
made in both the vertical and horizontal polarization, and the maximum value is
presented in the report.
The measurement was performed with a quasi-peak detector.
Disturbance radiation due to the fundamental and harmonic frequencies of the
local oscillator and the other source were measured on a selected number of FM
sound broadcast channels. About the Disturbance radiation value from the other
source, the sixteen maximum values were recorded.
The test was measured with the main unit and the remote control unit.
obtain maximum value of the electric field intensity. The measurement was
made in both the vertical and horizontal polarization, and the maximum value is
presented in the report.
The measurement was performed with a quasi-peak detector.
Disturbance radiation due to the fundamental and harmonic frequencies of the
local oscillator and the other source were measured on a selected number of FM
sound broadcast channels. About the Disturbance radiation value from the other
source, the sixteen maximum values were recorded.
The test was measured with the main unit and the remote control unit.
6.3. Measurement uncertainty
Radiated disturbance electric field intensity, 30 ~ 300 ㎒: ±2.0 ㏈
Radiated disturbance electric field intensity, 300 ~ 1,000 ㎒: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
6.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Test site
Open area test site
-
Measurement
Receiver
R & S
ESCI
100348
Signal Generator
Anritsu
MG3632A
MT79870
Test DVD
TDV-540
N/A
Bi-conical Ant.
Schwarzbeck
VHA9103
9103 1135
Log-periodic Ant.
Schwarzbeck
UHALP 9108-A 91081098
Ant. Master
EMCO
1051-12
90121554
Turn table
EMCO
1080-1.211
90121504
Reference No. : 54120906E Page 9/60
◀ Anam EMC Test Laboratory ▶
6.5. Test protocols
Date: June 08, 2009
Disturbance radiation due to the local oscillator.
Disturbance radiation due to the local oscillator.
Disturbance value(㏈㎶/m)
Channel Harmonic Measured
freq. (㎒)
Limit
(㏈㎶/m)
Horizon Vertical
1
98.2
60.0
* *
2
196.4
52.0
* *
3
294.6
52.0
* *
4
392.8
56.0
* *
87.5 5 491.0
56.0 * *
6
589.2
56.0
* *
7
687.4
56.0
* *
8
785.6
56.0
* *
9
883.8
56.0
* *
10
982.0
56.0
* *
1
108.7
60.0
* *
2
217.4
52.0
* *
3
326.1
56.0
* *
98.0 4 434.8
56.0 * *
5
543.5
56.0
* *
6
652.2
56.0
* *
7
760.9
56.0
* *
8
869.6
56.0
* *
9
978.3
56.0
* *
1
118.7
60.0
* *
2
237.4
52.0
* *
3
356.1
56.0
* *
108.0 4 474.8
56.0 * *
5
593.5
56.0
* *
6
712.2
56.0
* *
7
830.9
56.0
* *
8
949.6
56.0
* *
Reference No. : 54120906E Page 10/60
◀ Anam EMC Test Laboratory ▶
Disturbance radiation due to the other source.
Disturbance value(㏈㎶/m)
Channel Harmonic Measured
freq. (㎒)
Limit
(㏈㎶/m)
Horizon Vertical
159.75
40.0
35.6 *
Others 172.03
40.0 36.6 *
221.19
40.0
32.8
*
30
~
1,000 ㎒
*: less than25.0 ㏈㎶/m
Limit
according
to
EN55013:2001+A2(2006)
Reference No. : 54120906E Page 11/60
◀ Anam EMC Test Laboratory ▶
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE
FREQUENCY RANGE 30MHz TO 1,000MHz
7.1. Operating environment
Temperature
: 26℃
Relative humidity : 52%
7.2. Test set-up and procedure
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒.
The level of the test signal, which was connected to the receiver through a
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
7.3. Measurement uncertainty
Antenna terminal disturbance voltage, Quasi-peak detection: ±2.0 ㏈
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
7.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
R & S
ESCI
100348
Measurement
Receiver
Receiver
Signal Generator
Anritsu
MG3632A
MT79870
Combining network
Municom
MCL ZFSC-2-11
N
N
942604
Matching pad
(50~75Ω)
(50~75Ω)
R & S
RAM 358
837254/004
* R & S: Rohde & Schwarz
Click on the first or last page to see other AVR 160 (serv.man2) service manuals if exist.