DOWNLOAD Harman Kardon AVR 158 (serv.man5) Service Manual ↓ Size: 4.13 MB | Pages: 111 in PDF or view online for FREE

Model
AVR 158 (serv.man5)
Pages
111
Size
4.13 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-158-sm5.pdf
Date

Harman Kardon AVR 158 (serv.man5) EMC - CB Certificate ▷ View online

Reference No.: 54121101B
Page 2/43
CONTENTS
Page
1. Client information
3
2. Equipment under test (EUT)
3
2.1 Identification of the EUT
2.2 Additional information about the EUT
3. Test specifications
4
3.1 Standards
3.2 Additions,deviations and exclusions from standards
3.3 Purpose of the test
4. Test summary
4
5. Input immunity  to RF voltages(in differential mode):S1
5
5.1 Test criteria  and test procedure
5.2 Measurement uncertainty
5.3 Test result
6. Immunity to RF voltages:S2a
6
6.1 Test criteria  and test procedure
6.2 Measurement uncertainty
6.3 Test result
7. Immunity to RF voltages (in common mode):S2b
7
7.1 Test criteria and test procedure
7.2 Measurement uncertainty
7.3 Test result
8. Immunity to ambient electromagnetic fields:S3
8
8.1 Test criteria and test procedure
8.2 Measurement uncertainty
8.3 Test result
9. Screening effectiveness:S4
9
9.1 Test criteria and test procedure
9.2 Measurement uncertainty
9.3 Test result
10. Test instrumentation
10
Annex-Measurement Data;
Annex A
: Input immunity to RF voltages(in differential mode)
11
Annex B
: Immunity to RF voltage 24
Annex C
: Immunity to RF voltage(in common mode)
35
Annex D
: Immunity to ambient electromagnetic fields
39
Annex E
: Screening effectiveness
42
 Anam EMC Test Laboratory ▶
Reference No.: 54121101B
Page 3/43
1. CLIENT INFORMATION
The EUT has been test by request of:
* Company
: Harman Consumer Group
  8500 Balboa Blvd., Northridge, CA 91329, USA
* Contact Person
: Mr. Tim Huang (Sr Compliance  Engineer)
  Mr  Aaron Butters
  Mr. Aaron Butters
* Tel.
: +86 755 8634 3778 / +1 818 895 3312
2. EQUIPMENT UNDER TEST(EUT)
2.1 Identification of the EUT
*Equipment 
: AV Receiver
*Equipment 
: AV Receiver
*Model No.
: AVR158/230, AVR156/230(Alt)
*Brand Name 
: Harman/Kardon
*Serial No.
: N/A
*Manufacturer
: DongGuan LiaoBu Anam Electronics
 (China)
  Xin Cheng Management Area, Liaobu Town, 
  Dongguan City  Guang Dong Province  China
  Dongguan City, Guang Dong Province, China
  Fax: 86-769-3216338  Tel: 86-769-3326888
*Power Rating
AC 230V, 50Hz,
*External signal
SPEAKER L/R/SL/SR/C
  In/Out terminal
PHONES
AUDIO(AUX1, CD, TAPE IN/OUT, VIDEO 1
               VIDEO 2 IN/OUT  DVD  AUX 2)
               VIDEO 2 IN/OUT, DVD, AUX 2)
COAXAIL, OPTICAL 1,2
COMPONENT VIDEO
COMPOSITE(VIDEO 1, 2 IN/OUT, DVD, MONITOR OUT)
HDMI 1,2,3, OUT
USB(Only service update)
*Tuner Section
: FM 87.5㎒ ~ 108㎒ (50㎑ Steps)
: AM 522㎑ ~ 1,620㎑ (9㎑ Steps)
2.2 Additional information about the EUT
The EUT consists of the following subsystems/modules/parts; none
The tests have been performed on the EUT provided with the following
 modifications; none
Reference No.: 54121101B
Page 4/43
3. TEST SPECIFICATIONS
3.1 Standards
EN55020(2007)
Sound and television broadcast receivers and associated equipment
  - Immunity characteristics - Limits and methods of measurement
3.2 Additions,deviations and exclusions from standards
No additions,deviations or exclusions have been made from standard.
3.3 Purpose of the test
Purpose of test: To determine whether the equipment under test fulfils the
EMC immunity requirements of the standard stated in section 3.1
4. TEST SUMMARY
The results in this report apply only to sample tested:
Passed
the test
  Note
(S1)Input immunity to RF voltages
Yes
(S2a)Immunity to RF voltages
Yes
(S2b)Immunity to RF voltages(in common mode)
Yes
(S3)Immunity to ambient electromagnetic fields
Yes
(S4)Screening effectiveness 
Yes
         Note : * N.A. = Not Applicable
The equipment does comply with the requirements
Measurement data see annex A,B,C,D and E.
 Anam EMC Test Laboratory ▶
Reference No.: 54121101B
Page 5/43
5. Input immunity to RF voltages (in differential mode)(S1)
5.1 Test criteria and test procedure
Operating environment;
Temperature         
: 18 ℃
Relative Humidity  
: 29 %
The criterion concerning acceptable  sound interference is a wanted to 
unwanted audio signal ratio of ≥40dB at a wanted signal level of 50mW.
The EUT was placed by 0.1m above a metallic ground plane of dimensions 
2 x 1 m. The measuring set-up was shown in figure 3 EN55020(2002).
The principle of operation was similar to the measuring set-up of figure 3 in
EN55020(2002).
The low pass filter was added to prevent the influence of the measuring results
by harmonics of the unwanted signal generators.
The speaker outputs of the EUT were applied to an 8Ω purely resistive load
(Ro) and then to the AF inputs of the test system.
The power supply of the EUT was connected to a standard voltage source
(without special filters).
The measurements were performed with test software TS9980 Ver.2.9.
5.2 Measurement uncertainty
Antenna input immunity ± 2.0dB
5.3 Test result of input immunity to RF voltages.
The equipment does comply with the requirements.
For the measurement data, see annex A
 Anam EMC Test Laboratory ▶
Page of 111