DOWNLOAD Harman Kardon AVR 151 (serv.man4) Service Manual ↓ Size: 1.65 MB | Pages: 32 in PDF or view online for FREE

Model
AVR 151 (serv.man4)
Pages
32
Size
1.65 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-151-sm4.pdf
Date

Harman Kardon AVR 151 (serv.man4) EMC - CB Certificate ▷ View online

Reference No.: 54121302D
Page 2/32
CONTENTS
Page
1. Client information
3
2. Equipment under test (EUT)
3
2.1 Identification of the EUT
2.2 Additional information about the EUT
3. Test specifications
4
3.1 Standards
3.2 Additions,deviations and exclusions from standards
3.3 Purpose of the test
4. Test summary
4
5. Input immunity  to RF voltages(in differential mode):S1
5
5.1 Test criteria  and test procedure
5.2 Measurement uncertainty
5.3 Test result
6. Immunity to RF voltages:S2a
6
6.1 Test criteria  and test procedure
6.2 Measurement uncertainty
6.3 Test result
7. Immunity to RF voltages (in common mode):S2b
7
7.1 Test criteria and test procedure
7.2 Measurement uncertainty
7.3 Test result
8. Immunity to ambient electromagnetic fields:S3
8
8.1 Test criteria and test procedure
8.2 Measurement uncertainty
8.3 Test result
9. Screening effectiveness:S4
9
9.1 Test criteria and test procedure
9.2 Measurement uncertainty
9.3 Test result
10. Test instrumentation
10
Annex-Measurement Data;
Annex A
: Input immunity to RF voltages(in differential mode)
11
Annex B
: Immunity to RF voltage 17
Annex C
: Immunity to RF voltage(in common mode)
28
Annex D
: Immunity to ambient electromagnetic fields
30
Annex E
: Screening effectiveness
32
 Anam EMC Test Laboratory ▶
Reference No.: 54121302D
Page 3/32
1. CLIENT INFORMATION
The EUT has been test by request of:
* Company
: Harman International Industries, Incorporated 
  8500 Balboa Blvd., Northridge, CA 91329, USA
* Contact Person
: Mr. Tim Huang (Sr Compliance  Engineer)
  Mr. Aaron Butters
* Tel.
: +86 755 8634 3778 / +1 818 895 3312
2. EQUIPMENT UNDER TEST(EUT)
2.1 Identification of the EUT
*Equipment 
: AV Receiver
*Model No.
: AVR151/230
*Brand Name 
:  Harman/Kardon
*Serial No.
: AN0146-0000010
*Manufacturer
: Harman International Industries, Incorporated 
  8500 Balboa Blvd., Northridge, CA 91329, USA
*Power Rating
AC 220-240V, 50/60Hz, 210W
*External signal
SPEAKER L, R, SL, SR, C
  In/Out terminal
AUDIO : ANALOG 1, 2, SUBWOOFER OUT
VIDEO : VIDEO 1,2, MONITOR OUT
HDMI : 1,2,3,4, MONITOR OUT
Optical 1, COAXIAL, IR IN, TRIGGER OUT
PHONES, USB
*Tuner Section
: FM 87.5㎒ ~ 108㎒ (50㎑ Steps)
: AM 522㎑ ~ 1,620㎑ (9㎑ Steps)
2.2 Additional information about the EUT
The EUT consists of the following subsystems/modules/parts; none
The tests have been performed on the EUT provided with the following
 modifications; none
 Anam EMC Test Laboratory ▶
Reference No.: 54121302D
Page 4/32
3. TEST SPECIFICATIONS
3.1 Standards
EN55020(2007)&+A11(2011)
Sound and television broadcast receivers and associated equipment
  - Immunity characteristics - Limits and methods of measurement
3.2 Additions,deviations and exclusions from standards
No additions,deviations or exclusions have been made from standard.
3.3 Purpose of the test
Purpose of test: To determine whether the equipment under test fulfils the
EMC immunity requirements of the standard stated in section 3.1
4. TEST SUMMARY
The results in this report apply only to sample tested:
Passed
the test
  Note
(S1)Input immunity to RF voltages
Yes
(S2a)Immunity to RF voltages
Yes
(S2b)Immunity to RF voltages(in common mode)
Yes
(S3)Immunity to ambient electromagnetic fields
Yes
(S4)Screening effectiveness 
Yes
         Note : * N.A. = Not Applicable
The equipment does comply with the requirements
Measurement data see annex A,B,C,D and E.
 Anam EMC Test Laboratory ▶
Reference No.: 54121302D
Page 5/32
5. Input immunity to RF voltages (in differential mode)(S1)
5.1 Test criteria and test procedure
Operating environment;
Temperature         
: 17 ℃
Relative Humidity  
: 42 %
The criterion concerning acceptable  sound interference is a wanted to 
unwanted audio signal ratio of ≥40dB at a wanted signal level of 50mW.
The EUT was placed by 0.1m above a metallic ground plane of dimensions 
2 x 1 m. The measuring set-up was shown in figure 3 EN55020(2007).
The principle of operation was similar to the measuring set-up of figure 3 in
EN55020(2007).
The low pass filter was added to prevent the influence of the measuring results
by harmonics of the unwanted signal generators.
The speaker outputs of the EUT were applied to an 8Ω purely resistive load
(Ro) and then to the AF inputs of the test system.
The power supply of the EUT was connected to a standard voltage source
(without special filters).
The measurements were performed with test software TS9980 
5.2 Measurement uncertainty
Antenna input immunity ± 2.0dB
5.3 Test result of input immunity to RF voltages.
The equipment does comply with the requirements.
For the measurement data, see annex A
 Anam EMC Test Laboratory ▶
Page of 32
Display

Harman Kardon AVR 151 (serv.man4) EMC - CB Certificate ▷ Download

  • DOWNLOAD Harman Kardon AVR 151 (serv.man4) Service Manual ↓ Size: 1.65 MB | Pages: 32 in PDF or view online for FREE
  • Here you can View online or download the EMC - CB Certificate for the Harman Kardon AVR 151 (serv.man4) in PDF for free, which will help you to disassemble, recover, fix and repair Harman Kardon AVR 151 (serv.man4) Audio. Information contained in Harman Kardon AVR 151 (serv.man4) EMC - CB Certificate (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.