Harman Kardon AVR 151 (serv.man3) EMC - CB Certificate ▷ View online
Reference No. : 54121302C Page 9/45
◀ Anam EMC Test Laboratory ▶
6.5. Test protocols
Date: January 31, 2013
Disturbance radiation due to the local oscillator.
Disturbance radiation due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit
(㏈㎶/m)
Disturbance value(㏈㎶/m)
Horizon Vertical
1
98.2
60.0
* *
2
196.4
52.0
* *
3
294.6
52.0
* *
4
392.8
56.0
* *
87.5 5 491.0
56.0 * *
6
589.2
56.0
* *
7
687.4
56.0
* *
8
785.6
56.0
* *
9
883.8
56.0
* *
10
982.0
56.0
* *
1
108.7
60.0
* *
2
217.4
52.0
* *
3
326.1
56.0
* *
98.0 4 434.8
56.0 * *
5
543.5
56.0
* *
6
652.2
56.0
* *
7
760.9
56.0
* *
8
869.6
56.0
* *
9
978.3
56.0
* *
1
118.7
60.0
* *
2
237.4
52.0
* *
3
356.1
56.0
* *
108.0 4 474.8
56.0 * *
5
593.5
56.0
* *
6
712.2
56.0
* *
7
830.9
56.0
* *
8
949.6
56.0
* *
Reference No. : 54121302C Page 10/45
◀ Anam EMC Test Laboratory ▶
Disturbance radiation due to the other source.
Channel Harmonic
Measured
freq. (㎒)
Limit
(㏈㎶/m)
Disturbance value(㏈㎶/m)
Horizon Vertical
35.8
40.0
* 33.6
Others 437.40
47.0 39.2 *
460.68
47.0 40.4 40.7
30
~
1,000 ㎒
*: less than25.0 ㏈㎶/m
Limit
according
to
EN55013:2001+A2(2006)
Reference No. : 54121302C Page 11/45
◀ Anam EMC Test Laboratory ▶
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE
FREQUENCY RANGE 30MHz TO 1,000MHz
7.1. Operating environment
Temperature
: 17℃
Relative humidity : 41%
7.2. Test set-up and procedure
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒.
The level of the test signal, which was connected to the receiver through a
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
7.3. Measurement uncertainty
Antenna terminal disturbance voltage, Quasi-peak detection: ±2.0 ㏈
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
7.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Measurement
Receiver
Receiver
R & S
ESCI
100348
Signal Generator
Anritsu
MG3632A
MT79870
Combining network
Municom
MCL ZFSC-2-11
N
N
942604
Matching pad
(50~75Ω)
(50~75Ω)
R & S
RAM 358
837254/004
* R & S: Rohde & Schwarz
Reference No. : 54121302C Page 12/45
◀ Anam EMC Test Laboratory ▶
7.5. Test protocols
Date: January 28, 2013
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
98.2
54.0
*
2
196.4
50.0
*
3
294.6
50.0
*
4
392.8
52.0
*
87.5 5 491.0
52.0 *
6
589.2
52.0
*
7
687.4
52.0
*
8
785.6
52.0
*
9
883.8
52.0
*
10
982.0
52.0
*
1
108.7
54.0
*
2
217.4
50.0
*
3
326.1
52.0
*
98.0 4 434.8
52.0 *
5
543.5
52.0
*
6
652.2
52.0
*
7
760.9
52.0
*
8
869.6
52.0
*
9
978.3
52.0
*
1
118.7
54.0
*
2
237.4
50.0
*
3
356.1
52.0
*
108.0 4 474.8
52.0 *
5
593.5
52.0
*
6
712.2
52.0
*
7
830.9
52.0
*
8
949.6
52.0
*