Reference No. : 54121302C                                                                                                                  Page 8/45
 
◀  Anam EMC Test Laboratory  ▶
 
 
6. DISTURBANCE RADIATION IN THE FREQUENCY RANGE 30MHz   
TO 1,000MHz
 
 
6.1. Operating environment 
Temperature 
: -6℃ 
Relative humidity  : 38% 
 
    6.2. Test set-up and procedure 
 
The measurement was performed on an open area test site with a reference   
 
ground plane and at a distance of 3m. The height of the measuring antenna was 
 
varied between 1 to 4m and the table was rotated a full revolution in order to 
obtain maximum value of the electric field intensity. The measurement was 
made in both the vertical and horizontal polarization, and the maximum value is   
presented in the report. 
The measurement was performed with a quasi-peak detector. 
Disturbance radiation due to the fundamental and harmonic frequencies of the 
local oscillator and the other source were measured on a selected number of FM 
sound broadcast channels. About the Disturbance radiation value from the other 
source, the sixteen maximum values were recorded. 
The test was measured with the main unit and the remote control unit. 
 
6.3. Measurement uncertainty 
 
Radiated disturbance electric field intensity, 30    ~    300 ㎒:  ±2.0 ㏈ 
 
Radiated disturbance electric field intensity, 300 ~ 1,000 ㎒:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
6.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Open area test site 
Measurement 
Receiver 
R & S 
ESCI 
100348 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Test Compact Disc 
Abex 
TCD-782 
N/A 
Bi-conical Ant. 
Schwarzbeck 
VHA9103 
9103 1135 
Log-periodic Ant. 
Schwarzbeck 
UHALP 9108-A  91081098 
Ant. Master 
EMCO 
1051-12 
90121554 
Turn table 
EMCO 
1080-1.211 
90121504 
 
 
Reference No. : 54121302C                                                                                                                  Page 9/45
 
◀  Anam EMC Test Laboratory  ▶
 
 
6.5. Test protocols 
 
Date: January 31, 2013 
Disturbance radiation due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit 
(㏈㎶/m) 
Disturbance value(㏈㎶/m) 
Horizon Vertical 
 1 
98.2 
60.0 
* * 
 2 
196.4 
52.0 
* * 
 3 
294.6 
52.0 
* * 
 4 
392.8 
56.0 
* * 
87.5 5 491.0 
56.0 * * 
 6 
589.2 
56.0 
* * 
 7 
687.4 
56.0 
* * 
 8 
785.6 
56.0 
* * 
 9 
883.8 
56.0 
* * 
 10 
982.0 
56.0 
* * 
 1 
108.7 
60.0 
* * 
 2 
217.4 
52.0 
* * 
 3 
326.1 
56.0 
* * 
98.0 4 434.8 
56.0 * * 
 5 
543.5 
56.0 
* * 
 6 
652.2 
56.0 
* * 
 7 
760.9 
56.0 
* * 
 8 
869.6 
56.0 
* * 
 9 
978.3 
56.0 
* * 
 1 
118.7 
60.0 
* * 
 2 
237.4 
52.0 
* * 
 3 
356.1 
56.0 
* * 
108.0 4 474.8 
56.0  * * 
 5 
593.5 
56.0 
* * 
 6 
712.2 
56.0 
* * 
 7 
830.9 
56.0 
* * 
 8 
949.6 
56.0 
* * 
 
 
Reference No. : 54121302C                                                                                                                  Page 10/45
 
◀  Anam EMC Test Laboratory  ▶
 
 
Disturbance radiation due to the other source.   
Channel Harmonic 
Measured 
freq. (㎒) 
Limit 
(㏈㎶/m) 
Disturbance value(㏈㎶/m) 
Horizon Vertical 
  
35.8 
40.0 
* 33.6 
Others  437.40 
47.0 39.2 * 
  
460.68 
47.0 40.4 40.7 
 30 
~    
 
 
 
1,000  ㎒ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*: less than25.0 ㏈㎶/m 
  Limit 
according 
to 
EN55013:2001+A2(2006)
 
 
         
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Reference No. : 54121302C                                                                                                                  Page 11/45
 
◀  Anam EMC Test Laboratory  ▶
 
 
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE   
  FREQUENCY RANGE 30MHz TO 1,000MHz
 
 
  7.1. Operating environment 
Temperature 
: 17℃ 
Relative humidity  : 41% 
 
    7.2. Test set-up and procedure 
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒. 
 
The level of the test signal, which was connected to the receiver through a 
combining network, was set to give 70 ㏈㎶  at the input of the EUT. 
The signal was an unmodulated carrier. 
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic 
frequencies was measured with the receiver tuned to a selected number of FM 
sound broadcast channels. Disturbance voltage due to all other sources was 
measured with the receiver tuned to the channel 98.3 ㎒ respectively. 
 
   7.3. Measurement uncertainty 
 
Antenna terminal disturbance voltage, Quasi-peak detection:  ±2.0 ㏈ 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
7.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Measurement 
                      Receiver 
R & S 
ESCI 
100348 
 
 
 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Combining network 
Municom 
MCL ZFSC-2-11 
942604 
Matching pad 
(50~75Ω) 
R & S 
RAM 358 
837254/004 
* R & S: Rohde & Schwarz 
 
 
 
 
 
 
 
 
Page of 45
Display