Harman Kardon AVR 151 (serv.man3) EMC - CB Certificate ▷ View online
Reference No. : 54121302C Page 3/45
◀ Anam EMC Test Laboratory ▶
8. Disturbance Power
13
8.1. Operating environment
8.2. Test set-up and procedure
8.3. Measurement uncertainty
8.4. Test instrumentation
8.5. Test protocol
8.2. Test set-up and procedure
8.3. Measurement uncertainty
8.4. Test instrumentation
8.5. Test protocol
9. Harmonics
15
9.1. Operating environment
9.2. Test set-up and procedure
9.3. Test instrumentation
9.4. Test result
9.2. Test set-up and procedure
9.3. Test instrumentation
9.4. Test result
10. Flicker
16
10.1. Operating environment
10.2. Test set-up and procedure
10.3. Test instrumentation
10.4. Test result
10.2. Test set-up and procedure
10.3. Test instrumentation
10.4. Test result
11. Photograph of Product
17
12. Photograph of the test set-up
20
Annex - Measurement data;
Annex A : Mains terminal disturbance voltage (6 Copies)
22
Annex B : Antenna terminal disturbance voltage (3 Copies)
28
Annex C : Disturbance Power (11 Copies)
31
Annex D : Harmonics (3 Copies)
42
Annex E : Voltage fluctuations-flicker (1 Copy)
45
Reference No. : 54121302C Page 4/45
◀ Anam EMC Test Laboratory ▶
1. CLIENT INFORMATION
The EUT has been tested by request of:
* Company
: Harman International Industries, Incorporated
8500 Balboa Blvd., Northridge, CA 91329, USA
* Contact Person
: Mr. Tim Huang (Sr Compliance Engineer)
Mr. Aaron Butters
* Tel.
: +86 755 8634 3778 / +1 818 895 3312
2. EQUIPMENT UNDER TEST (EUT)
2.1. Identification of the EUT
*Equipment AV
Receiver
*Model No.
AVR151/230
*Brand Name
Harman/Kardon
*Serial No.
AN0146-0000010
*Manufacturer
Harman International Industries, Incorporated
8500 Balboa Blvd., Northridge, CA 91329, USA
8500 Balboa Blvd., Northridge, CA 91329, USA
*Power Rating
AC 220-230V~, 50/60Hz, 210W
*Tuner Section
FM 87.5 ㎒ ~ 108 ㎒
AM 522 ㎑ ~ 1,620 ㎑
AM 522 ㎑ ~ 1,620 ㎑
*External signal
In/Out terminal
SPEAKER(L, R, SL, SR, C)
AUDIO : ANALOG 1, 2, SUBWOOFER OUT
VIDEO : VIDEO 1,2, MONITOR OUT
HDMI : 1,2,3,4, MONITOR OUT
Optical 1, COAXIAL, IR IN, TRIGGER OUT
PHONES, USB
AUDIO : ANALOG 1, 2, SUBWOOFER OUT
VIDEO : VIDEO 1,2, MONITOR OUT
HDMI : 1,2,3,4, MONITOR OUT
Optical 1, COAXIAL, IR IN, TRIGGER OUT
PHONES, USB
2.2. Additional Information about the EUT
The EUT consists of the following Subsystems/Modules/Parts: N/A
The test have been performed on the EUT provided with the following
modifications : None.
Reference No. : 54121302C Page 5/45
◀ Anam EMC Test Laboratory ▶
3. TEST SPECIFICATIONS
3.1. Standards
*EN55013 (2001)&A1(2003)+A2(2006) :
Sound and Television broadcast receivers and Associated equipment
-Radio Disturbance characteristics - Limits and methods of measurement.
-Radio Disturbance characteristics - Limits and methods of measurement.
*
EN61000-3-2(2006)&+A2(2009)
Part 3-2: Limits- Limits for harmonic current emissions
(Equipment input current ≤16A per phase)
*EN61000-3-3(2008):
Part 3-3: Limits- Limitation of voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems for equipment with rated
current
≤
16A.
3.2. Additions, deviations and exclusions from standard
No additions, deviations or exclusions have been made from standard.
3.3. Purpose of the test:
To determine whether the EUT fulfils the EMC-emission requirements of the
Standards stated in section 3.1.
3.4. Mode of operation during the test
The EUT was operated in such a way as to deliver one-eighth on the non-clipped
output power to the rated load impedance using the sinusoidal of 1 ㎑ & color-
bar.
The EUT was set to the mode of Tuner.
4. TEST SUMMARY
The results in this report apply only to sample(s) tested:
Test item
Passed
the test
Note
Mains terminal disturbance voltage
Yes
Disturbance Radiation
Yes
Antenna Terminal Disturbance Voltage
Yes
Disturbance Power
Yes
Harmonics Yes
Flicker Yes
The equipment does comply with the requirements.
For the measurement data, see Annex.
Reference No. : 54121302C Page 6/45
◀ Anam EMC Test Laboratory ▶
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY
RANGE 0.15MHz TO 30MHz
5.1. Operating environment
Temperature
: 17℃
Relative humidity : 41 %
5.2. Test set-up and procedure
The mains terminal disturbance voltage was measured with the EUT in a
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
5.3. Measurement uncertainty
Mains terminal disturbance voltage, quasi-peak detection: ±2.0dB
Mains terminal disturbance voltage, average detection : ±2.0dB
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.