Harman Kardon AVR 147 (serv.man3) EMC - CB Certificate ▷ View online
Reference No. : 54120707A Page 16
◀ Anam EMC Test Laboratory ▶
Video3 S-Video
135.1 48.8 38.8 19.2 *
Video3 Video/Audio
147.4 49.3 39.3 20.3 *
Coaxial 3
42.20
45.4 35.4 *
*
Phones
110.6 47.9 37.9 23.1 22.4
/
/
/
/
*: less than 25 ㏈㎺
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex B (36 Copies).
Reference No. : 54120707A Page 17
◀ Anam EMC Test Laboratory ▶
9. HARMONICS
9.1. Operating environment
Temperature
: 28℃
Relative humidity : 50%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2 : 2000.
The measurement was performed with the Test software (Version 3.07.04)
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
Signal Generator
Anritsu
MG3632A
MT79870
Universal power analyzer Voltech
PM 3300
AK19/1137
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).
Reference No. : 54120707A Page 18
◀ Anam EMC Test Laboratory ▶
10. VOLTAGE FLUCTUATIONS-FLICKER
10.1. Operating environment
Temperature
: 15℃
Relative humidity : 40%
10.2. Test set-up and procedure
The open circuit test voltage was the rated voltage of the EUT.
The reference impedance was a conventional impedance being used to calculate
or measure the disturbance caused by an appliance.
or measure the disturbance caused by an appliance.
The measurement was performed with the Test software (Version 3.07.04)
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
10.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
Signal Generator
Anritsu
MG3632A
MT79870
Reference impedance
Voltech
IEC Standard 555
IB16/0725
Universal power analyzer Voltech
PM 3300
AK19/1137
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
10.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex D (2 Copies).
Reference No. : 54120707A Page 19
11. Photograph of Product
11.1 Front view of product
11.2 Rear view of product
◀ Anam EMC Test Laboratory ▶
Click on the first or last page to see other AVR 147 (serv.man3) service manuals if exist.