Harman Kardon AVR 142 (serv.man3) EMC - CB Certificate ▷ View online
- Page 8 of 10 -
Report
No.
123035
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.1.1
DK: To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification
:
Heavy Current Regulations, Section 107
Class II apparatus
N/A
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification:
SI 525: 1997
When marketing in Ireland,
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
N/A
- Page 9 of 10 -
Report
No.
123035
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.1.1
Cont.
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification:
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification:
Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
1998).
No mains socket- outlets
N/A
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification
: SI 1768: 1994
P
- Page 10 of 10 -
Report
No.
123035
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification
: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
provided.
Noted
P
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
Not TV set.
N/A
IT:User instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
DE: The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV,
authorization is required, or application of type
approval (Bauartzulassung) and marking.
for the display of visual images operating at an
acceleration voltage exceeding 40 kV,
authorization is required, or application of type
approval (Bauartzulassung) and marking.
Justification
: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
No CRT used in the
equipment.
equipment.
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
Justification
: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
exportation of Chemical Products (Certain Cases)
Considered.
P
- Page 1 of 1 -
Report
No.
123035
ATTACHMENT 4
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
APPENDIX: SINGAPORE DEVIATIONS
to IEC 60065 7
th
ed. (2001)
(CB Bulletin No. 105A, May 2003)
Clause
Requirement – Test
Result - Remark
Ver-
dict
4
All apparatus must be tested to 230 Vac
230 Vac tested
P
4.3.13
Apparatus fitted with voltage selector switch must
be tested as follows:
be tested as follows:
Connect apparatus to 230 V ac mains with voltage
selector switch to settings not suitable for operation
at 230 V ac.
selector switch to settings not suitable for operation
at 230 V ac.
No voltage selector.
N/A
5.3
Circuit diagrams must be indicated with component
values.
values.
P
Circuit diagrams of electronic modules in the
apparatus must be provided.
apparatus must be provided.
P
7.1, 11.2
Permissible temperature rises of 10K less than
those specified in Table 2 are required.
those specified in Table 2 are required.
Meets tropical limits
P
10.2
Humidity treatment. Adopt the testing conditions
designed for tropical conditions.
designed for tropical conditions.
5 days
P
15.1.1
All Class I apparatus must be fitted with 3-pin mains
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
Class II apparatus
N/A
a) All Class II apparatus must be fitted with 2-pin
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
N/A
b) Class II apparatus that are fitted with 3-pin mains
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
PSB approved plug provided
P
15.3
Apparatus
≥ 3 kW must be connected to fixed
wiring. All connection to fixed wiring must be in
accordance with Code of Practice CP5.
accordance with Code of Practice CP5.
< 3 kW
N/A
16
Detachable power cord set must be listed in the test
report critical component list.
report critical component list.
Not detachable
N/A
Misc.
Apparatus enclosure which is shaped and
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
Not shaped like toy.
P