Harman Kardon AVR 142 (serv.man3) EMC - CB Certificate ▷ View online
- Page 7 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Hazardous live terminals ……………………………:
No hazardous live terminals.
The output signal will rise to
28.4Vpeak at maximum output
power if the speaker output
load is disconnected. No hazard.
The output signal will rise to
28.4Vpeak at maximum output
power if the speaker output
load is disconnected. No hazard.
P
Supply output terminals (other than mains) …...:
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
Use of triangle with exclamation mark …………….:
Correct symbol applied:
- Imprinted on rear side of the
apparatus in connection with
CAUTION of opening.
- In circuit diagram for critical
components.
- Imprinted on rear side of the
apparatus in connection with
CAUTION of opening.
- In circuit diagram for critical
components.
P
5.4
Instructions for use ………………………….:
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc. ……………………….:
dripping or splashing. Warning concerning objects
filled with liquid, etc. ……………………….:
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring ...:
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery …..:
No lithium battery in the
equipment.
equipment.
N/A
d) Class I earth connection warning ………….:
Class II apparatus
N/A
e) Instructions for multimedia system connection …..:
Instructions for multimedia
system connection provided in
user manual.
system connection provided in
user manual.
P
f) Special stability warning for attachment of the
apparatus to the flor/wall ……………:
apparatus to the flor/wall ……………:
No such equipment
N/A
g) Warning: battery exposure to heat …………..:
No battery
N/A
h) Warning: protective film on CRT face …….:
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings ….:
switch location, accessibility and markings ….:
Plug is regarded as disconnect
device and is readily operable.
device and is readily operable.
P
Instructions for permanently connected equipment:
Not permanently connected
equipment.
equipment.
N/A
Marking, signal lamps or similar for completely
disconnection from the mains …………..…:
disconnection from the mains …………..…:
Information provided in user
manual.
manual.
P
- Page 8 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h) ………….:
No ionizing radiation
N/A
Ionizing radiation under fault condition …………….:
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ….:
No laser radiation
N/A
Emission limits under fault conditions ……………..:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated …...:
fuse links and other protective devices defeated …...:
No fuse links operate during
normal operating condition.
(see appended table 7.1)
normal operating condition.
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts ………………..:
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation ……………………………………………..:
insulation ……………………………………………..:
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier …………………………………..:
mechanical barrier …………………………………..:
(see appended table 7.1)
P
7.1.4
Temperature rise of windings ………………………:
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C :
See appended table 7.2 for
mains connector (wafer)
CN91 and CN92.
mains connector (wafer)
CN91 and CN92.
P
8
Constructional requirements with regard to the protection against electric shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare ………………………:
untreated textile oxide films and beads etc.
considered to be bare ………………………:
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc. ………….:
device, fuse-links or handling drawers etc. ………….:
Operation “By hand” not
possible
possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material ………………………..:
hygroscopic material ………………………..:
No hygroscopic insulation.
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the removal
of a cover which can be removed by hand ……..:
from parts rendered accessible following the removal
of a cover which can be removed by hand ……..:
No live terminals or parts
removable by hand.
removable by hand.
N/A
8.5
Class I equipment …………………...:
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts ……………………:
earthed accessible parts ……………………:
N/A
- Page 9 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Resistors bridging basic insulation complying with
14.1 a) ……………………………..:
14.1 a) ……………………………..:
No such resistors
N/A
Capacitors bridging basic insulation complying with
14.2.1 a) ……………………………….......:
14.2.1 a) ……………………………….......:
No such capacitors
N/A
Protective earthing terminal ………………...:
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment ………………………...:
Class I equipment ………………………...:
Class II apparatus
P
Double or reinforced insulation between hazardous
live parts and accessible parts ……………..:
live parts and accessible parts ……………..:
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3 ………………..:
complying with 14.1 a) or 14.3 ………………..:
The equipment has isolating
transformers. complies with
clause 14.3
transformers. complies with
clause 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3. ………………………...:
with 14.3.4.3. ………………………...:
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a) :
bridged by a capacitor complying with 14.1 a) :
No such capacitors
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a) :
capacitors in series complying with 14.2.1 a) :
No such capacitors
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b) ……:
single capacitor complying with 14.2.1 b) ……:
No such capacitors
N/A
8.7
This clause is void ……………………..:
—
8.8
Basic or supplementary insulation > 0,4 mm (mm):
N/A
Reinforced insulation > 0,4 mm (mm) ….:
Main and sub transf. bobbins
(ref. 14.3)
(ref. 14.3)
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22) …………………:
sheet insulation. See 8.22) …………………:
No thin sheet insulation
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 …………….....:
layers, each meeting 10.3 …………….....:
Not used
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 …………………......:
two of which meet 10.3 …………………......:
Not used
N/A
Reinforced insulation, two layers each of which meet
10.3…………………………………...:
10.3…………………………………...:
Not used
N/A
Reinforced insulation, three layers any two which
meet 10.3 …………………………….:
meet 10.3 …………………………….:
Not used
N/A
- Page 10 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts …………..:
conductors and accessible parts …………..:
Double insulated.
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts:
parts and conductors connected to accessible parts:
Single insulation but safety
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts. …………...:
the mains and accessible parts. …………...:
Double insulated
according to 8.9. and 10.3
according to 8.9. and 10.3
P
Double insulation between internal hazardous live
parts and conductors connected to accessible
parts.………………………………………:
parts and conductors connected to accessible
parts.………………………………………:
Single insulation but safety
anchored.
anchored.
N/A
8.11
Detaching of wires …………………………………..:
N/A
No undue reduction of creepages or clearance
distances if wires become detached ………………:
distances if wires become detached ………………:
Primary wires are connected
with multi-contact housing.
with multi-contact housing.
P
Vibration test carried out ………………………:
See 12.1.2
N/A
8.12
This clause is void ………………………..:
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s) ………………...:
etc. (pull test 20 N for 10 s) ………………...:
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s) ……………………………………..:
10 s) ……………………………………..:
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges ………………:
due to hot parts or sharp edges ………………:
Wires safely anchored away
from parts with high temperature.
from parts with high temperature.
P
8.16
Only special supply equipment can be used …....:
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation ……………………………………………..:
insulation ……………………………………………..:
No such winding wire.
N/A
8.18
Endurance test as required by 8.17 ……….:
N/A
8.19
Disconnection from the mains
See below
P
8.19.1
Disconnect device ……………………...:
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation ………………………………:
separation ………………………………:
No all-pole switch or circuit
breaker
breaker
N/A
8.19.2
Mains switch ON indication …………...:
Indicator lamp or FL display
lit-on
lit-on
P
8.20
Switch not fitted in the mains cord ………:
P