Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate ▷ View online
- Page 5 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
No test box required. Tested
according to manufacturers
instructions
according to manufacturers
instructions
N
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ................................... :
Brand: Harman / Kardon
Model: AVR 140/230.
See copy of marking plate.
Model: AVR 140/230.
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol .......................... :
AC-symbol (
~
) with 230V
marked
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ..................... :
300W
P
5.2 Earth
terminal
Class II apparatus
N
Hazardous live terminals
No hazardous live terminals
P
Supply output terminals (other than mains)
The power and current marked
closed to the socket-outlets;
closed to the socket-outlets;
UNSWTCHED (100W MAX, 0.5A)
SWITCHED (50W MAX, 0.25A)
SWITCHED (50W MAX, 0.25A)
P
5.3
Use of triangle with exclamation mark
Correct symbol applied:
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found.
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary of
Testing.
following language: English.
See comments in Summary of
Testing.
P
TRF No: IEC/EN 60065F
- Page 6 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled
with liquid, etc.
or splashing. Warning concerning objects filled
with liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N
Instructions for replacing lithium battery
No lithium battery in the
equipment
equipment
N
Instructions for modem if fitted
None
N
Class I earth connection warning
Class II apparatus
N
Instructions for multimedia system connection
Not applicable
N
Special stability warning for fixed installation
Not for fixed installation
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug is regarded as disconnect
device and is readily operable.
device and is readily operable.
P
Instructions for permanently connected equipment
Not permanently connected
equipment
equipment
N
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No CRT
N
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
No laser
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during
normal operating conditions.
See also appended table.
normal operating conditions.
See also appended table.
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
TRF No: IEC/EN 60065F
- Page 7 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No temperatures measured
during heating test and fault
condition tests require this test
(7.2) to be performed.
during heating test and fault
condition tests require this test
(7.2) to be performed.
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible
not possible
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by hand
N
8.5
Class I equipment
Class II equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II apparatus.
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
The apparatus have isolating
transformers.
transformers.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such capacitors.
N
TRF No: IEC/EN 60065F
- Page 8 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such capacitors.
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
No such capacitors.
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No parts at 35V to 71V (peak)
a.c. or 60V to 120V d.c.
a.c. or 60V to 120V d.c.
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No parts at 35-71V(peak) a.c. or
60-120V d.c.
60-120V d.c.
N
Separation by Class II isolating transformer
Isolating transformer according to
14.3.2. (Class II)
14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation > 0,4 mm (mm) .................... :
Transformer bobbin,
See appended table and
attachment, Table to
EN/IEC 60065 7
See appended table and
attachment, Table to
EN/IEC 60065 7
th
edition
P
Thin sheet insulation
No thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but safely
anchored
anchored
P
TRF No: IEC/EN 60065F