Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate ▷ View online

 
 
- Page 2 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
Testing 
Date of receipt of test item ........................................... :
Date(s) of performance of test………………………: 
 
April 2006 
 
April 2006 
General remarks 
 
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory  
and appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02. 
 
This report shall not be reproduced except in full without the written approval of the testing laboratory. 
 
The test results presented in this report relate only to the item(s) tested. 
 
"(see appended table)" refers to a table appended to the report. 
“(see remark #)” refers to a remark appended to the report. 
“(see Annex #) refers to an annex appended to the report. 
 
Throughout this report a comma (point) is used as the decimal separator. 
 
 
 
Summary of Testing and Conclusions 
 
The sample(s) tested complies with the requirements of IEC/EN 60065:2002.  
Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC and 
Singapore deviations, and recorded at the end of this report. 
 
 
Name and address of production sites (Factories): 
 
Factory 1:
 
Anam Electronics Co., Ltd. 
645, Sungkok-Dong, Ansan-City, Kyungki-Do, Korea
 
 
Factory 2:
 
DongGuan LiaoBu Anam Electronics. 
Xin Cheng Management Area, LiaoBu Town, DongGuan City, GuangDong Province, China.
 
 
 
 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 3 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
Copy of marking plate: 
 
 
 
 
 
 
 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 4 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
Summary of testing: 
 
The apparatus under test is  A/V Surround  Receiver of insulation class II. 
The apparatus have Front / Center / Surround / Surround Back Amplifier Circuits, Tuner Circuit, Several 
Signal In/Out terminals (RCA, Antenna, Optical, S-video) and Speaker terminal provided 
(see also photos).  
 
The equipment applied condition of tropical climates for Singapore. 
 
Instructions : Instructions/users manual is only in English. The information shall be given in a language 
acceptable to the country where the apparatus is intended to be sold.
 
 
List of attachments: 
 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
National Deviations for Singapore 
 
Photos 
 
Attachment, Tables to EN/IEC 60065 7
th
 edition
 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 5 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus ................................. :
Class II 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 Ventilation 
instructions 
require the use of the test 
box 
No test box required. Tested 
according to manufacturers 
instructions 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
On front and rear side of the 
enclosure
 
 
Permanent durability against water and petroleum 
spirit 
Tested with water / spirit 
5.1 Identification, 
maker, model ................................... :
Brand: Harman / Kardon 
Model: AVR 140/230. 
See copy of marking plate. 
 
Class II symbol if applicable 
Class II symbol is applied in 
according to IEC 60417-5172. 
 
Rated supply voltage and symbol .......................... :
AC-symbol ( 
~
 ) with 230V  
marked 
 
Frequency if safety dependant 
50Hz 
 
Rated current or power consumption ..................... :
300W 
5.2 Earth 
terminal 
Class II apparatus 
 
Hazardous live terminals 
No hazardous live terminals 
 
Supply output terminals (other than mains) 
The power and current marked 
closed to the socket-outlets; 
UNSWTCHED (100W MAX, 0.5A) 
SWITCHED (50W MAX, 0.25A)
 
5.3 
Use of triangle with exclamation mark 
Correct symbol applied: 
Imprinted on rear side in 
connection with CAUTION of 
opening. Further; no incorrect 
use of this symbol is found.
 
5.4 
Instructions for use 
User information in the 
following language: English. 
See comments in Summary of 
Testing. 
TRF No:  IEC/EN 60065F 
Page of 48