Harman Kardon AVR 138 EMC - CB Certificate ▷ View online
- Page 4 of 39 -
Report
No.
112419
Copy of marking plate and summary of test results (information/comments):
Model, AVR 138/230
- Page 5 of 39 -
Report
No.
112419
Summary of testing:
The apparatus under test is A/V Surround Receiver of insulation class II.
The apparatus have Front / Center / Surround Amplifier Circuits, Tuner Circuit, Several Signal In/Out
terminals (RCA, Antenna, Optical, S-video) and Speaker terminals (see also photos).
The equipment applied condition of tropical climates for Singapore.
The model AVR 137/230 is basic model.
The model AVR 138/230 is identical to tested basic model AVR 137/230, except for model designation.
Instructions:
Instructions/users manual is only in English. The information shall be given in a language
acceptable to the country where the apparatus is intended to be sold.
List of attachments:
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
ANNEX ZC TO EN 60 065, A-DEVIATIONS
National deviations for Singapore
Attachment, Tables to EN/IEC 60065 7
ANNEX ZC TO EN 60 065, A-DEVIATIONS
National deviations for Singapore
Attachment, Tables to EN/IEC 60065 7
th
edition
Attachment, Schematic diagram
Photos.
- Page 6 of 39 -
Report
No.
112419
Test item particulars .................................................. :
A/V Surround Receiver
Classification of installation and use ...................... :
Class II
Supply connection .................................................... :
By non-detachable power supply cord
to mains socket.
to mains socket.
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : Pass (P)
- test object does not meet the requirement ........... : Fail (F)
Testing:
Date of receipt of test items ..…….………………….:
July 2008
Date(s) of performance of tests ................................ :
August 2008
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
The sample(s) tested complies with the requirements of IEC 60065: 2001 + A1 / EN 60065: 2002 + A1.
Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC,
Compliance with European Special National Conditions, Annex ZB, and A – Deviations, Annex ZC,
and
National deviations for Singapore, and recorded at the end of this report.
- Page 7 of 39 -
Report
No.
112419
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II apparatus.
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test box
No test box required.
Tested according to
manufacturers instructions
Tested according to
manufacturers instructions
P
5 MARKING
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum spirit
Tested with water / sprit
P
5.1 Identification,
maker, model .................................... :
Maker: harman / kardon
Model: AVR 137/230 or
Model: AVR 137/230 or
AVR 138/230
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol ........................... :
AC-symbol (
~
) with 230V
marked
P
Frequency if safety dependant
50Hz
P
Rated current or power consumption ..................... :
235W
P
5.2 Earth
terminal
Class II apparatus
N/A
Hazardous live terminals
No hazardous live terminals
The output signal will rise to
28Vpeak at maximum out
power if the speaker output load
is disconnected, no hazard
The output signal will rise to
28Vpeak at maximum out
power if the speaker output load
is disconnected, no hazard
.
P
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
Use of triangle with exclamation mark
Correct symbol applied:
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found
Imprinted on rear side in
connection with CAUTION of
opening. Further; no incorrect
use of this symbol is found
P
Click on the first or last page to see other AVR 138 service manuals if exist.