Harman Kardon AURA (serv.man8) EMC - CB Certificate ▷ View online
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 3 of 45
Table of Contents
1. TEST RESULT SUMMARY ............................................................................................................................................... 4
2. GENERAL DESCRIPTION OF EUT ................................................................................................................................. 5
2.1
APPLICANT .................................................................................................................................................................... 5
2.2
MANUFACTURER ......................................................................................................................................................... 5
2.3
BASIC
DESCRIPTION
OF
EQUIPMENT
UNDER
TEST ............................................................................................. 5
3. LABORATORY AND ACCREDITATIONS ..................................................................................................................... 6
3.1
LABORATORY ............................................................................................................................................................... 6
3.2
ACCREDITATIONS ........................................................................................................................................................ 6
3.3
MEASUREMENT
UNCERTAINTY ............................................................................................................................... 6
3.4
TEST
INSTRUMENTS .................................................................................................................................................... 7
3.5
MONITORING
OF
EUT
FOR
THE
IMMUNITY
TEST ................................................................................................. 8
4. EMISSION TEST .................................................................................................................................................................. 9
4.1
CONDUCTED
EMISSION
MEASUREMENT ............................................................................................................... 9
4.1.1 LIMITS ...................................................................................................................................................................... 9
4.1.2 TEST PROCEDURES ............................................................................................................................................... 9
4.1.3 TEST SETUP .......................................................................................................................................................... 10
4.1.4 TEST RESULTS ...................................................................................................................................................... 11
4.2
DISTURBANCE
POWER
MEASUREMENT ............................................................................................................... 19
4.2.1 LIMITS .................................................................................................................................................................... 19
4.2.2 TEST PROCEDURES ............................................................................................................................................. 19
4.2.3 TEST SETUP .......................................................................................................................................................... 19
4.2.4 TEST RESULTS ...................................................................................................................................................... 20
5. IMMUNITY TEST .............................................................................................................................................................. 25
5.1
GENERAL
DESCRIPTION ........................................................................................................................................... 25
5.2
GENERAL
PERFORMANCE
CRITERIA
DESCRIPTION .......................................................................................... 26
5.3
ELECTROSTATIC
DISCHARGE
(ESD) ...................................................................................................................... 27
5.3.1 TEST SPECIFICATION .......................................................................................................................................... 27
5.3.2 TEST PROCEDURE ............................................................................................................................................... 27
5.3.3 TEST SETUP .......................................................................................................................................................... 28
5.3.4 TEST RESULTS ...................................................................................................................................................... 29
5.4
ELECTRICAL
FAST
TRANSIENT/BURST
IMMUNITY
TEST ................................................................................. 30
5.4.1 TEST SPECIFICATION .......................................................................................................................................... 30
5.4.2 TEST PROCEDURE ............................................................................................................................................... 30
5.4.3 TEST SETUP .......................................................................................................................................................... 30
5.4.4 TEST RESULTS ...................................................................................................................................................... 31
5.5
IMMUNITY
TO
RF
VOLTAGE
OF
MAINS,
LOUDSPEAKER,
HEADPHONE
AND
AUDIO
CONNECTERS
(S2A)
.............................................................................................................................................................................................. 32
5.5.1 TEST REQUIREMENT ........................................................................................................................................... 32
5.5.2 TEST SETUP .......................................................................................................................................................... 33
5.5.3 TEST RESULTS ...................................................................................................................................................... 34
5.6
IMMUNITY
TO
AMBIENT
ELECTROMAGNETIC
FIELDS
(S3) ............................................................................. 36
5.6.1 TEST REQUIREMENT ........................................................................................................................................... 36
5.6.2 TEST RESULTS ...................................................................................................................................................... 37
APPENDIX A: PHOTOGRAPH OF THE TEST CONFIGURATION ............................................................................. 38
APPENDIX B: PHOTOGRAPHS OF EUT .......................................................................................................................... 41
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 4 of 45
1. TEST RESULT SUMMARY
EMISSION (EN 55013:2001+A1:2003+A2:2006)
Standard
Item
Remarks
Result
EMISSION (EN
55013:2001+A1:2003+
A2:2006)
Conducted emission
measurement
Table 1
Pass
Disturbance voltage at the
antenna terminals
Table 2
N/A
Disturbance power
Table 4
Pass
IMMUNITY (EN 55020:2007+A11:2011)
Standard
Item
Requirements of Performance
Result
EN 61000-4-2:2009
ESD
Criterion B
Pass
EN 61000-4-4: 2012
EFT
Criterion B
Pass
EN
55020:2007+A11:2011
55020:2007+A11:2011
S2a
Meets the requirements of subpart
4.3.2 in EN 55020
Pass
EN
55020:2007+A11:2011
55020:2007+A11:2011
S3
Meets the requirements of subpart
4.3.4 in EN 55020
Pass
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 5 of 45
2. GENERAL DESCRIPTION OF EUT
2.1 APPLICANT
Name:
Harman International Industries, Incorporated
Address:
8500 Balboa Blvd, Northridge, CA 91329, United States
2.2 MANUFACTURER
Name:
Harman International Industries, Incorporated
Address:
8500 Balboa Blvd, Northridge, CA 91329, United States
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST
Equipment:
Wireless stereo speaker
Model No.:
HARMAN KARDON AURA
Trade Name:
HARMAN/KARDON
Power supply:
AC Adapter:
Adaptor input 100-240V~50/60Hz 1.5A Max output DC19V,3A
Speaker input: DC 19V,3A
Test Mode:
Mode 1: Audio in (EUT is playing a 1KHz audio signal. EUT is connecting
with mobile phone through an audio line.)
Mode 2: WIFI
Mode 3: BT (EUT is working on Bluetooth connection with mobile phone.)
Mode 4: Optical (EUT is working on Optical connection with DVD)
Mode 5: Standby
with mobile phone through an audio line.)
Mode 2: WIFI
Mode 3: BT (EUT is working on Bluetooth connection with mobile phone.)
Mode 4: Optical (EUT is working on Optical connection with DVD)
Mode 5: Standby
Sample
submitting way :
submitting way :
■Provided by customer □Sampling
Note: /
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 6 of 45
3. LABORATORY AND ACCREDITATIONS
3.1 LABORATORY
The tests and measurements in this report except Input Immunity was performed by EMC
Laboratory of Guangzhou GRG Metrology and Test CO., LTD.
Add.
: 163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China
Telephone: +86-20-38699959, 38699960, 38699961
Fax
: +86-20-38695185
Input Immunity was performed by CGEL, Guangzhou EMC Laboratory.
3.2 ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies according to
ISO/IEC 17025.
ISO/IEC 17025.
USA
FCC Listed Lab No. 688188
China
CNAS NO.L0446
China
DILAC No.DL175
Canada
Registration No.:8355A-1
3.3 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2:
Measurement
Frequency
Uncertainty
Radiated
Emission
Emission
Horizontal
30MHz~1000MHz
4.2dB
Vertical
30MHz~1000MHz
4.4dB
Conducted Emission
9kHz~30MHz
3.1 dB
This uncertainty represents an expanded uncertainty factor of k=2.