Harman Kardon AURA (serv.man3) EMC - CB Certificate ▷ View online
Report No.: EM201300550-9 Application No.: ZJ00032797 Page 17 of 69
Project No.:
ZJ00032797
Polarziation:
Vertical
Standard:
(RE)EN55022 class B
_3m_1-6GHz_PK
_3m_1-6GHz_PK
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-9-6
Temp./Hum.(%RH): 22.3/55%RH
Time:
9:59:30
EUT: (RE)EN55022_class
B_3m
Distance:
3m
Model:
HARMAN KARDON AURA
Test Result:
Pass
Note:
Mode 2: WIFI
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1
2312.783
35.82 15.88 51.70 70.00
-18.30 peak
2
2312.783
15.92 15.88 31.80 50.00
-18.20 AVG
3
2373.331
39.09 16.23 55.32 70.00
-14.68 peak
4
2373.331
17.17 16.23 33.40 50.00
-16.60 AVG
5
4921.593
29.99 28.04 58.03 74.00
-15.97 peak
6
4921.593
18.16 28.04 46.20 54.00 -7.80 AVG
7
5242.525
29.71 27.94 57.65 74.00
-16.35 peak
8
5242.525
18.36 27.94 46.30 54.00 -7.70 AVG
9
5395.241
30.77 27.75 58.52 74.00
-15.48 peak
10
5395.241
18.05 27.75 45.80 54.00 -8.20 AVG
11
5697.766
29.44 28.09 57.53 74.00
-16.47 peak
12
5697.766
17.61 28.09 45.70 54.00 -8.30 AVG
Report No.: EM201300550-9 Application No.: ZJ00032797 Page 18 of 69
Project No.:
ZJ00032797
Polarziation:
Horizontal
Standard: (RE)EN55022_class
B_3m
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-9-3
Temp./Hum.(%RH): 20/54%RH
Time:
14:49:10
EUT:
Wireless stereo speaker
Distance:
3m
Model:
HARMAN KARDON AURA
Test Result:
Pass
Note:
Mode 2: WIFI
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1
161.4740
21.64 10.66 32.30 40.00 -7.70
QP
2
149.4857
21.71 10.09 31.80 40.00 -8.20
QP
3
209.3129
17.40 11.90 29.30 40.00
-10.70 QP
4
214.5142
15.31 12.19 27.50 40.00
-12.50 QP
5
185.1379
16.32 11.28 27.60 40.00
-12.40 QP
6
233.3487
14.06 13.04 27.10 47.00
-19.90 QP
Report No.: EM201300550-9 Application No.: ZJ00032797 Page 19 of 69
Project No.:
ZJ00032797
Polarziation:
Horizontal
Standard:
(RE)EN55022 class B
_3m_1-6GHz_PK
_3m_1-6GHz_PK
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-9-6
Temp./Hum.(%RH): 22.3/55%RH
Time:
9:59:12
EUT:
Wireless stereo speaker
Distance:
3m
Model:
HARMAN KARDON AURA
Test Result:
Pass
Note:
Mode 2: WIFI
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1
2352.974
30.73 16.11 46.84 70.00
-23.16 peak
2
2352.974
17.09 16.11 33.20 50.00
-16.80 AVG
3
4865.389
31.69 27.89 59.58 74.00
-14.42 peak
4
4865.389
18.61 27.89 46.50 54.00 -7.50 AVG
5
4992.762
29.82 28.23 58.05 74.00
-15.95 peak
6
4992.762
17.67 28.23 45.90 54.00 -8.10 AVG
7
5287.880
30.26 27.89 58.15 74.00
-15.85 peak
8
5287.880
18.21 27.89 46.10 54.00 -7.90 AVG
9
5488.998
28.76 27.64 56.40 74.00
-17.60 peak
10
5488.998
17.96 27.64 45.60 54.00 -8.40 AVG
11
5897.515
29.04 28.58 57.62 74.00
-16.38 peak
12
5897.515
17.22 28.58 45.80 54.00 -8.20 AVG
Report No.: EM201300550-9 Application No.: ZJ00032797 Page 20 of 69
Project No.:
ZJ00032797
Polarziation:
Vertical
Standard: (RE)EN55022_class
B_3m
Power Source:
AC 230V/50Hz
Test item:
Radiation Test
Date:
2013-9-3
Temp./Hum.(%RH): 20/54%RH
Time:
13:31:36
EUT:
Wireless stereo speaker
Distance:
3m
Model:
HARMAN KARDON AURA
Test Result:
Pass
Note:
Mode 3:BT
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV/m)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1 41.7937
17.10 12.70 29.80 40.00
-10.20 QP
2 45.2145
16.93 11.47 28.40 40.00
-11.60 QP
3 65.5167 26.99 7.81 34.80 40.00 -5.20
QP
4
149.6606
24.20 10.10 34.30 40.00 -5.70
QP
5
161.0029
21.63 10.67 32.30 40.00 -7.70
QP
6
218.0829
18.62 12.38 31.00 40.00 -9.00
QP
Click on the first or last page to see other AURA (serv.man3) service manuals if exist.