TEST REPORT
IEC 60950
Safety of information technology equipment
Report Reference No. .................... : SPCLVD31229
Compiled by (+ signature)............... : Eddie Shue
Engineer
Reviewed by (+ signature) .............. : Peter Lai
Supervisor
....................................................
Date of issue................................... : December 29, 2003
This report is based on a blank test report that was prepared by KEMA using information obtained from the
TRF originator (see below).
TRF originator (see below).
Testing laboratory name............... : Superior Product Consulting, INC.
Address .......................................... : 3F, No. 10, Alley 6, Lane 235, Pao Chiao Rd., Hsien Tien, Taipei,
Taiwan, R.O.C.
Testing location .............................. : Superior Product Consulting, INC.
Address .......................................... : 3F, No. 10, Alley 6, Lane 235, Pao Chiao Rd., Hsien Tien, Taipei,
Taiwan, R.O.C.
Client name.................................... : SALOM ELECTRIC (THAILAND) CO LTD.
Address .......................................... : 39/19 MOO 5 SOI BANG PLAO-SRISATIEN THUMBOL RAIKEING
AMPHUR SAMPHAN NAKHON PATHOM 73110, THAILAND
Standard......................................... : IEC 60950, 3
rd
Edition (1999)
EN 60950, 3
rd
Edition (2000)
Test procedure .............................. : Informative Test Report
Procedure deviation........................ : N/A
Non-standard test method............... : N/A
Test Report Form/blank test report
Test Report Form No. ..................... : I950___F/00-03
TRF originator................................. : FIMKO
Master TRF .................................... : dated 00-02
Copyright reserved to the bodies participating in the IECEE Schemes (CB and CB-FCS) and/or the bodies
participating in the C.I.G (CCA-ENEC).
participating in the C.I.G (CCA-ENEC).
Test item description...................... : Power Supply
Trademark ...................................... :
or
Model and/or type reference ........... : PS6 or SSB-0124
Manufacturer .................................. : Same as Applicant.
Rating(s)......................................... : Input rating: 120-240V ac, 50/60 Hz, 3A max.
Output rating: 24V dc, 4A
page 2 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
Copy of marking plate
page 3 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
Test item particulars:
Equipment mobility ................................................... : movable
Operating condition .................................................. : continuous
Tested for IT power systems..................................... : No
IT testing, phase-phase voltage (V)........................... : N/A
Class of equipment................................................... : Class I
Mass of equipment (kg) ............................................ : 0.45 Kg
Protection against ingress of water............................ : IPXO
Possible test case verdicts:
- test case does not apply to the test object ............... : N / A
- test object does meet the requirement..................... : Pass
- test object does not meet the requirement ............... : Fail
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Report.
- "(see appended table)" refers to a table appended to the Report.
- Throughout this report a point is used as the decimal separator.
The test results presented in this report relate only to the object tested. This report shall not be reproduced,
except in full, without the written approval of the Issuing testing laboratory.
This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB
in accordance with IECEE 02.
- "(see appended table)" refers to a table appended to the Report.
- Throughout this report a point is used as the decimal separator.
The test results presented in this report relate only to the object tested. This report shall not be reproduced,
except in full, without the written approval of the Issuing testing laboratory.
This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB
in accordance with IECEE 02.
General product information:
It is specified for use in a Tmra of 25°C maximum.
page 4 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
Comply with IEC 950 or relevant component
standard
standard
(see appended table)
Pass
1.5.2
Evaluation and testing components
Certified components are used
in accordance with their
ratings, certifications and they
comply with applicable parts of
this Standard.
in accordance with their
ratings, certifications and they
comply with applicable parts of
this Standard.
Pass
Dimensions (mm) of mains plug for direct plug-in .: Not direct plug-in equipment.
N/A
Torque and pull test of mains plug for direct
plug-in; torque (Nm); pull (N)
plug-in; torque (Nm); pull (N)
N/A
1.5.3
Transformers
Transformer used is suitable for
their intended application and
comply with the relevant
requirements of the standard
and particularly those of Annex
C.
their intended application and
comply with the relevant
requirements of the standard
and particularly those of Annex
C.
Pass
1.5.4
Flammability class of high voltage components
(component; manufacturer; flammability)
(component; manufacturer; flammability)
No high-voltage components.
N/A
1.5.5
Interconnecting cables
No interconnecting cables
provided as part of the
equipment.
provided as part of the
equipment.
Pass
1.5.6
Mains capacitors
Between lines: X2 type, PCB
location X1 and X2, sub-class
capacitors according to IEC
60384-14:1993 with 21 days
damp heat test.
location X1 and X2, sub-class
capacitors according to IEC
60384-14:1993 with 21 days
damp heat test.
Pass