Harman Kardon ABH-4 (serv.man10) EMC - CB Certificate ▷ View online
page 26 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
5.3
Abnormal operating and fault conditions
Pass
5.3.1
Protection against overload and abnormal
operation
operation
(see enclosed test record)
Pass
5.3.2
Motors
N/A
5.3.3
Transformers
Transformers are constructed
in accord with the applicable
Clause and Annex C.
in accord with the applicable
Clause and Annex C.
Pass
5.3.4
Functional insulation ......................................... : Functional insulation between
the phases before the fuse
complies with method (a),
other operation insulation
complies with method (C).
Short-circuit tests, results see
nclosed test record.
complies with method (a),
other operation insulation
complies with method (C).
Short-circuit tests, results see
nclosed test record.
Pass
5.3.5
Electromechanical components
The equipment does not have
any electromechanical
components in the secondary.
any electromechanical
components in the secondary.
N/A
5.3.6
Simulation of faults
See enclosed test record for
abnormal operation tests.
abnormal operation tests.
Pass
5.3.7
Unattended equipment
The equipment does not have
any thermostats, temperature
limiters, or thermal cut-outs.
any thermostats, temperature
limiters, or thermal cut-outs.
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire, emission of molten
metal or deformation was
noted during the tests.
metal or deformation was
noted during the tests.
Electric strength tests
performed after abnormal and
fault tests.
performed after abnormal and
fault tests.
Pass
page 27 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service personnel, and users of
other equipment connected to the network, from hazards in the equipment
other equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Test voltage (V) ................................................:
Current in the test circuit (mA) ........................:
6.1.2.2
Exclusions.........................................................:
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of telecommunication wiring system from overheating
N/A
Max. output current (A)...................................... :
Current limiting method ..................................... :
page 28 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total
mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples, material ............................................. :
Wall thickness (mm).......................................... :
A.1.2
Conditioning of samples; temperature (
°
C) ........ :
N/A
A.1.3
Mounting of samples ......................................... :
N/A
A.1.4
Test flame
N/A
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) ................................. :
Sample 2 burning time (s) ................................. :
Sample 3 burning time (s) ................................. :
A.2
Flammability test for fire enclosures of movable equipment having a total
mass not exceeding 18 kg, and for material and components located inside
fire enclosures (see 4.7.3.2 and 4.7.3.4)
mass not exceeding 18 kg, and for material and components located inside
fire enclosures (see 4.7.3.2 and 4.7.3.4)
N/A
A.2.1
Samples, material ............................................. :
Wall thickness (mm).......................................... :
A.2.6
Compliance criteria
N/A
Sample 1 burning time (s) ................................. :
Sample 2 burning time (s) ................................. :
Sample 3 burning time (s) ................................. :
A.2.7
Alternative test acc. to IEC 60695-2-2, cl. 4, 8
N/A
Sample 1 burning time (s) ................................. :
Sample 2 burning time (s) ................................. :
Sample 3 burning time (s) ................................. :
A.3
High current arcing ignition test (see 4.7.3.2)
N/A
A.3.1
Samples, material ............................................ :
Wall thickness (mm).......................................... :
A.3.5
Compliance criteria
N/A
Sample 1 number of arcs to ignition (pcs).......... :
Sample 2 number of arcs to ignition (pcs).......... :
Sample 3 number of arcs to ignition (pcs) ......... :
Sample 4 number of arcs to ignition (pcs) ......... :
Sample 5 number of arcs to ignition (pcs).......... :
A.4
Hot wire ignition test (see 4.7.3.2)
N/A
A.4.1
Samples, material ............................................. :
Wall thickness (mm).......................................... :
page 29 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
A.4.5
Compliance criteria
N/A
Sample 1 ignition time (s) .................................. :
Sample 2 ignition time (s) .................................. :
Sample 3 ignition time (s) .................................. :
Sample 4 ignition time (s) .................................. :
Sample 5 ignition time (s) .................................. :
A.5
Hot flaming oil test (see 4.6.2)
N/A
A.6
Flammability tests for classifying materials V-0, V-1 or V-2
N/A
A.6.1
Samples, material ............................................. :
Wall thickness (mm).......................................... :
A.6.5
Compliance criteria
N/A
A.6.6
Permitted re-test
N/A
A.7
Flammability test for classifying foamed materials HF-1, HF-2 or HFB
N/A
A.7.1
Sample, material ............................................... :
Wall thickness (mm).......................................... :
A.7.4
Compliance criteria
N/A
A.7.5
Compliance criteria, HF-2
N/A
A.7.6
Compliance criteria, HF-1
N/A
A.7.7
Compliance criteria, HBF
N/A
A.7.8
Permitted re-test, HF-1 or HF-2
N/A
A.7.9
Permitted re-test, HBF
N/A
A.8
Flammability test for classifying materials HB
N/A
A.8.1
Samples, material ............................................. :
Sample thickness (mm)..................................... :
A.8.2
Conditioning of samples; temperature (
°
C) ........ :
N/A
A.8.4
Test procedure
N/A
A.8.5
Compliance criteria
N/A
A.8.6
Permitted re-test
N/A
A.9
Flammability test for classifying materials 5V
N/A
A.9.1
Samples, material ............................................. :
Sample thickness (mm)..................................... :
A.9.4
Test procedure, test bars
N/A
A.9.5
Test procedure, test plaques
N/A
A.9.6
Compliance criteria
N/A
A.9.7
Permitted re-test
N/A
A.10
Stress relief conditioning (see 4.2.7)
N/A
Temperature (
°
C) .............................................. :