Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1.7
Marking and instructions
Pass
1.7.1
Rated voltage (V) ................................................: Input rating: 120-240V ac,
Output rating: 24V dc, 4A
Pass
Symbol of nature of supply for d.c. .......................:
Mains from AC source
N/A
Rated frequency (Hz) ..........................................: 50/60 Hz
N/A
Rated current (A) ................................................: 3 A.
Pass
Manufacturer ......................................................: SALOM ELECTRIC
(THAILAND) CO LTD
Pass
Trademark ..........................................................:
or
Pass
Type/model ........................................................: PS6 or SSB-0124
Pass
Symbol of Class II ...............................................: The equipment is regarded as
Class I
N/A
Certification marks ..............................................: CE, UL
Pass
1.7.2
Safety instructions
Operating/safety instructions
made available to the user.
made available to the user.
Pass
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Marking for voltage setting/frequency setting ........: Equipment is full ranging.
N/A
1.7.5
Marking at power outlets .....................................: No standard power outlets are
provided.
N/A
1.7.6
Marking at fuseholders ........................................: T3.15A, 250V
Pass
1.7.7
Wiring terminals
See below.
Pass
1.7.7.1
Protective earthing terminals
Appliance inlet is provided.
N/A
1.7.7.2
Terminal for external primary power supply
conductors
conductors
N/A
1.7.8.1
Identification, location and marking ................... :
N/A
1.7.8.2
Colours ........................................................... :
N/A
1.7.8.3
Symbols according to IEC 60417 ...................... :
N/A
1.7.8.4
Markings using figures .................................... : Figures are not used for
indicating different positions of
controls.
controls.
N/A
1.7.9
Isolation of multiple power sources ................... : There is only one connection
to hazardous voltages.
N/A
1.7.10
IT power system
Not intended for use on IT
power systems.
power systems.
N/A
page 7 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
1.7.11
Thermostats and other regulating devices
No thermostats or similar
regulating devices.
regulating devices.
N/A
1.7.12
Language ......................................................... : Reviewed only English
markings/instructions.
May be provided in other
languages when the
equipment will be applied for
other national certificated.
languages when the
equipment will be applied for
other national certificated.
1.7.13
Durability
All markings provided on UL
Recognized Component
labels suitable for surface they
are applied upon.
Recognized Component
labels suitable for surface they
are applied upon.
Pass
1.7.14
Removable parts
No marking is located on (a)
removable part(s).
removable part(s).
Pass
1.7.15
Replaceable batteries
The lithium battery is not
located in an Operator Access
Area.
located in an Operator Access
Area.
N/A
Language.......................................................... :
1.7.16
Operator access with a tool ............................... : No operator access areas
require the use of a tool.
Pass
1.7.17
Equipment for restricted access locations.......... : Equipment not intended for
installation in a RESTRICTED
ACCESS LOCATION.
ACCESS LOCATION.
N/A
page 8 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in OPERATOR access areas
The construction of this plastic
enclosure prevents the
accessibility to any parts with
only basic insulation to ELV or
hazardous voltage with test
pin or test finger.
enclosure prevents the
accessibility to any parts with
only basic insulation to ELV or
hazardous voltage with test
pin or test finger.
Pass
2.1.1.1
Access to energized parts
The operator has access to
bare parts of SELV
CIRCUITS.
bare parts of SELV
CIRCUITS.
No operator access to
energized parts.
energized parts.
Pass
Test by inspection ............................................ : Operator cannot contact with
any parts with only basic
insulation to ELV or
hazardous voltage.
insulation to ELV or
hazardous voltage.
Pass
Test with test finger .......................................... : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
basic insulation, or ELV
circuits.
Pass
Test with test pin .............................................. : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe .......................................... : No TNV present.
N/A
2.1.1.2
Battery compartments ....................................... : No battery components.
N/A
2.1.1.3
Access to ELV wiring
Internal wiring in an ELV
circuit is not user accessible.
circuit is not user accessible.
N/A
Working voltage (V); distance (mm) through
insulation
insulation
2.1.1.4
Access to hazardous voltage circuit wiring
No internal wiring accessible
to the user.
to the user.
N/A
2.1.1.5
Energy hazards ................................................ : No hazardous voltage wiring
in operator accessible area.
Pass
2.1.1.6
Manual controls
No shafts or knobs, etc. at
ELV, TNV or hazardous
voltage.
ELV, TNV or hazardous
voltage.
N/A
2.1.1.7
Discharge of capacitors in the primary circuit
No risk of electric shock.
Pass
Time-constant (s); measured voltage (V) ........... : See enclosed test record.
2.1.2
Protection in service access areas
No bare parts operating at
HAZARDOUS VOLTAGES in
a service access area.
HAZARDOUS VOLTAGES in
a service access area.
N/A
2.1.3
Protection in restricted access locations
The unit is not intended to be
used in restricted locations.
used in restricted locations.
N/A
page 9 of 42
Report No.SPCLVD31229
TRF No.: I950___D
TRF originator: FIMKO
2.2
SELV circuits
Pass
2.2.1
General requirements
SELV levels are maintained
after single fault condition.
after single fault condition.
Pass
2.2.2
Voltages under normal conditions (V) ................ : All accessible voltages are
less than 42.4 Vp or 60 V dc
and are classified as SELV.
and are classified as SELV.
Pass
2.2.3
Voltages under fault conditions (V) .................... : Under fault conditions
voltages never exceed 71V
peak and 120Vdc and do not
exceed 42.4V peak or 60V dc
for more than 0.2 sec.
peak and 120Vdc and do not
exceed 42.4V peak or 60V dc
for more than 0.2 sec.
Pass
2.2.3.1
Separation by double or reinforced insulation
(method 1)
(method 1)
Hazardous voltage wiring
which may contact SELV
parts provided with double or
reinforced insulation. See
2.10.5.
which may contact SELV
parts provided with double or
reinforced insulation. See
2.10.5.
Pass
2.2.3.2
Separation by earthed screen (method 2)
Method 1 used.
N/A
2.2.3.3
Protection by earthing of the SELV circuit (method
3)
3)
Method 1 used.
N/A
2.2.4
Connection of SELV circuits to other circuits....... : SELV circuit and all
interconnected circuits
separated from primary by
Reinforced/Double insulation.
separated from primary by
Reinforced/Double insulation.
The SELV circuit does not
exceed the SELV limits under
normal and fault conditions.
exceed the SELV limits under
normal and fault conditions.
SELV circuits are only
connected to other secondary
circuits.
connected to other secondary
circuits.
Pass