Sony BDP-S790 Service Manual ▷ View online
1-18
1) 1 piece of BU is put into “Bag,Charge Prevention” and
excess part of bag is folded back.
excess part of bag is folded back.
2) The BU and Manual instruction are put into Tray (PSFM)
and lid is put on it. Then it is stored in individual carton.
3) 40pcs of individual carton are
stored in master carton.
4) Seal is attached to top and bottom of carton with PP tape.
(So called “H” shape)
(So called “H” shape)
Manual Instruction
1-4-7. KEM480AAA/C2RP1 Packing
Lid foam tray (480RP)
Antistatic bag
Mechanical deck
Cushion carton (480RP)
C surface cut facing front
Individual carton
Individual carton
PP tape
Shipment label
BDP-S790
1-19
1-4-8. BU Data Decode Jig
・
・
・
JIG Name : BDPRdec.exe
Release : 2011.8.25
Version : 3.0.0.0
Release : 2011.8.25
Version : 3.0.0.0
Software Contents
BDPRdec.exe ; Software
BDPRdec.exe ; Software
(initial destination is C:\BuData.txt)
TasmanBars.dll ; decode dll
Uninst.exe ; unregistration BDPRdec.exe from PC
TasmanBars.dll ; decode dll
Uninst.exe ; unregistration BDPRdec.exe from PC
Installations
2.Check the attached 2D code photo(OK_sample.JPG) drag-and-drop onto BDPRdec.exe, the
3.If there is the error message (.NET frame work requirements) please apply
Microsoft .NET Framework 2.0 (or 2.0 SP1) from Microsoft download site.
Microsoft .NET Framework 2.0 (or 2.0 SP1) from Microsoft download site.
STEP 1
Microsoft .NET Framework Version 2.0 Redistributable Package (x86)
Microsoft .NET Framework Version 2.0 Redistributable Package (x86)
http://www.microsoft.com/downloads/details.aspx?displaylang=en&FamilyID=0856eacb-4362-4b0d-8edd-aab15c5e04f5
STEP 2
Microsoft .NET Framework 2.0 Service Pack 1 (x86)
Microsoft .NET Framework 2.0 Service Pack 1 (x86)
http://www.microsoft.com/downloads/details.aspx?displaylang=en&FamilyID=79bc3b77-e02c-4ad3-aacf-a7633f706ba5
How to use
Case1
Drag-and-drop 2Dcode photo onto BDPRdec.exe
Case1
Drag-and-drop 2Dcode photo onto BDPRdec.exe
Case2
Player : ****BDP.txt
Recoder: ****BRD.txt
Recoder: ****BRD.txt
Remarks
・
・
・
・
BDP-S790
1-20
1-4-10. Laser Caution Label
The Loading Assy service parts do not have Laser Caution Label.
So that please reuse the original Laser Caution label and paste it on top of
new Holder, Chuck Assy.
Limit Sample
Following peel off condition are acceptable
1-4-9. Loading For Service
BDP 7G Loading Assy service parts consists from 2 parts.
① Holder, Chuck Assy
Loading Assy
②
“Loading for service”
A-1850-153-A
1-839-582-11
FFC (SPD)
Laser Caution Label
1-839-583-11
FFC (LDG)
Holder, Chuck Assy
①
Loading Assy
②
1-839-585-11
FFC (OPT)
BDP-S790
Currently these parts are producing by 2 vendors. Please
DO NOT COMBINE
① and ②
(From diferent vendor) because
THERE IS NO COMPATIBILITY
.
1-21
In case of BU assy replacement:
1. OP related data for new assy is controlled by BU factory
2. All of data is recorded into a barcode label
3. The label is put on the assy
4. Service parts will be followed
5. In service, the data should be read out from problem assy
6. The read data should be saved to new assy
Fact finding:
1. The label is “DATA MATRIX” format
2. The number of data is 91 words
3. The method of reading and saving is required when BU and
main board are replaced.
New service method
1. All of BU data on the barcode label is shot by digital camera in
order to make a JPEG file of BU data.
2. Application software in the PC makes digital data from JPEG file.
3. The converted data is stored to USB memory.
4. The USB memory is connected to BDP 7G unit.
5. In service mode, there is a command to save the data from USB
memory to board memory.
BDP-S790