MX-3100N  MX-DEX6/DEX7  2 – 1
MX-3100N
Service Manual
 
[2] MX-DEX6/DEX7
1. Unpacking
A. Removal of the desk unit
B. Removal of the fixing material and packing 
parts
* If the connector is removed first, it may be pinched in the install-
ing procedures. Therefore, keep it packed when unpacking the
package, and unpack it when connecting the connector to the
machine.
1)
Remove the fixing material and packing parts.
C. Check the packed items
1)
Check that all the items are included in the package.
2. Installation
<Note before installation>
* Before starting installation, check to insure that the data lamp on
the operation panel does not light up or blink.
A. Turn off the power of the main unit
1)
Turn OFF the power switch on the operation panel.
2)
Open the front cabinet. 
Turn OFF the power switch in the front cabinet of the main
unit.
3)
Disconnect the power plug of the main unit from the power out-
let.
No.
Names of bundles
Quantity
1
Right adjuster
1
2
Fixing screws (M4 x 8)
4
1
2
<State of switch>
ON
OFF
OFF
MX-3100N  MX-DEX6/DEX7  2 – 2
B. Installation of the adjuster
1)
Install the right adjuster (package part No. 1) to the desk unit.
2)
Turn each adjuster to fix the desk unit.
C. Connection of the main unit and the desk unit
1)
Remove the connection plate covers of the both sides of the
main unit.
2)
Put the main unit on the desk unit.
* Use man power of four persons or more to lift the main unit.
* Place the main unit on the desk unit slowly by fitting the
external lines. Check to insure that the positioning pin on the
top of the desk unit is securely engaged in the positioning
groove of the main unit.
3)
Remove the No. 2 paper feed tray.
4)
Pull out the No. 3 paper feed tray until it stops.
1
2
2
1
1
2
MX-3100N  MX-DEX6/DEX7  2 – 3
5)
Lift the connection plates on the right and left of the main unit
front side, and fix them with the fixing screws (package part
No. 2).
6)
Replace the No. 3 and No. 2 trays to the original positions.
7)
Lift the connection plates, and fix them with the fixing screws.
8)
Install the connection plate covers.
1
2
2
1
2
1
MX-3100N  MX-DEX6/DEX7  2 – 4
D. Release the lock
1)
Pull out each tray.
2)
Turn and remove the fixing material, and remove the caution
sheet.
3)
Attach the removed fixing material to the position shown in the
figure for storage.
4)
Close the cassette which was pulled out.
E. Connector connection
1)
Remove the screw from the back of the main unit. Remove the
connector cover.
2)
Connect the connector.
3)
Split the removed connector cover along the perforated line.
4)
Install the connector cover and fix it with a screw.
NOTE:
Before turning on the power, check to insure that the fixing 
material of the tray is disengaged. If the power is turned on 
without disengaging the fixing material, a trouble may be 
resulted.