4. Remove four screws and remove the Boiler.
5. Remove six screws and remove the Indication PCB.
6. Slide the Grip fixing plate as arrow and remove it.
- 6 -
7. With the Lid opened, put the plastic slotted driver, etc. and lift up the Panel.
8. Close the Supply water lid and remove the Panel as the Figure.
(Be careful to remove the both-side tape neatly.)
9. Unscrew three screws and remove the Ring and the Test switch
rubber.
- 7 -
10. Remove the Main switch pushing the inside of the Main
case.
11. Remove the Hinge as the Figure and remove the Water supply
lid.
- 8 -
12. Remove the Faucet rubber from the Water supply lid.
13. Unscrew the screw from the Main case and remove the Water supply lid open button.
14. Remove the Overflow pin (with O-ring) from the Main case as the Figure.